Search NASA⌕ Search

Engineering topics

Spiering, Barry A.

Publications and source records attributed to Spiering, Barry A..

Changes in Distal Tibial Microarchitecture During Eight Weeks of U.S. Army Basic Combat Training Differ by Sex and Race

ABSTRACT Basic combat training (BCT) is a physically rigorous period at the beginning of a soldier's career that induces bone formation in the tibia. Race and sex are determinants of bone properties in young adults but their influences on changes in bone microarchitecture during BCT are unknown. The purpose of this work was to determine the influence of sex and race on changes in bone microarchitecture during BCT. Bone microarchitecture was assessed at the distal tibia via high‐resolution peripheral quantitative computed tomography at the beginning and end of 8 weeks of BCT in a multiracial cohort of trainees (552 female, 1053 male; mean ± standard deviation [SD] age = 20.7 ± 3.7 years) of which 25.4% self‐identified as black, 19.5% as race other than black or white (other races combined), and 55.1% as white. We used linear regression models to determine whether changes in bone microarchitecture due to BCT differed by race or sex, after adjusting for age, height, weight, physical activity, and tobacco use. We found that trabecular bone density (Tb.BMD), thickness (Tb.Th), and volume (Tb.BV/TV), as well as cortical BMD (Ct.BMD) and thickness (Ct.Th) increased following BCT in both sexes and across racial groups (+0.32% to +1.87%, all p < 0.01). Compared to males, females had greater increases in Tb.BMD (+1.87% versus +1.40%; p = 0.01) and Tb.Th (+0.87% versus +0.58%; p = 0.02), but smaller increases in Ct.BMD (+0.35% versus +0.61%; p < 0.01). Compared to black trainees, white trainees had greater increases in Tb.Th (+0.82% versus +0.61%; p = 0.03). Other races combined and white trainees had greater increases in Ct.BMD than black trainees (+0.56% and + 0.55% versus +0.32%; both p ≤ 0.01). Changes in distal tibial microarchitecture, consistent with adaptive bone formation, occur in trainees of all races and sexes, with modest differences by sex and race. Published 2023. This article is a U.S. Government work and is in the public domain in the USA. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.

Hughes, Julie M.↗

Maximizing Strength: The Stimuli and Mediators of Strength Gains and Their Application to Training and Rehabilitation

Abstract Spiering, BA, Clark, BC, Schoenfeld, BJ, Foulis, SA, and Pasiakos, SM. Maximizing strength: the stimuli and mediators of strength gains and their application to training and rehabilitation. J Strength Cond Res 37(4): 919–929, 2023—Traditional heavy resistance exercise (RE) training increases maximal strength, a valuable adaptation in many situations. That stated, some populations seek new opportunities for pushing the upper limits of strength gains (e.g., athletes and military personnel). Alternatively, other populations strive to increase or maintain strength but cannot perform heavy RE (e.g., during at-home exercise, during deployment, or after injury or illness). Therefore, the purpose of this narrative review is to (a) identify the known stimuli that trigger gains in strength; (b) identify the known factors that mediate the long-term effectiveness of these stimuli; (c) discuss (and in some cases, speculate on) potential opportunities for maximizing strength gains beyond current limits; and (d) discuss practical applications for increasing or maintaining strength when traditional heavy RE cannot be performed. First, by conceptually deconstructing traditional heavy RE, we identify that strength gains are stimulated through a sequence of events, namely: giving maximal mental effort, leading to maximal neural activation of muscle to produce forceful contractions, involving lifting and lowering movements, training through a full range of motion, and (potentially) inducing muscular metabolic stress. Second, we identify factors that mediate the long-term effectiveness of these RE stimuli, namely: optimizing the dose of RE within a session, beginning each set of RE in a minimally fatigued state, optimizing recovery between training sessions, and (potentially) periodizing the training stimulus over time. Equipped with these insights, we identify potential opportunities for further maximizing strength gains. Finally, we identify opportunities for increasing or maintaining strength when traditional heavy RE cannot be performed.

Sport Sciences↗

Comparison of Different Variants of the U.S. Army Occupational Physical Assessment Test

The U.S. Army Occupational Physical Assessment Test (OPAT) is a pre-enlistment physical employment screening assessment developed to place recruits and soldiers into Military Occupational Specialties (MOSs) based on their physical capabilities in order to optimize performance and limit injury. The OPAT consists of the seated power throw (SPT), strength deadlift (SDL), standing long jump, and interval aerobic run. During the scientific validation of the OPAT, two variants of the SPT and two variants of the SDL were used. Although the OPAT was validated using both variants for each test, U.S. Army scientists and policymakers have received queries regarding how these variants compare to each other. Therefore, the purpose of this study was to compare different variants of the SPT and SDL. Thirty-two participants (14 male and 18 female) between the ages of 18 and 42 years visited the laboratory on one occasion and performed two variants of the SPT (seated on the ground [the current OPAT standard] versus seated in a chair with a 35 cm seat height) and two variants of the SDL (using a hex-bar [the current OPAT standard] versus using paired dumbbells). Testing order for the different variants was randomized. The protocol was approved by the U.S. Army Medical Research and Development Command Institutional Review Board. Performing the SPT from a chair significantly (P < .05) increased performance when compared to performing the SPT from the ground (5.4 ± 1.3 m versus 5.0 ± 1.4 m, respectively). Values for the two SPT variants were correlated (tau = 0.90). Performing the SDL using the hex-bar significantly increased the maximal weight lifted when compared to performing the SDL using paired dumbbells (86.9 ± 18.4 kg versus 83.1 ± 18.0 kg, respectively). Values for the two SDL variants were correlated (tau = 0.83). Performing different variants of the SPT and SDL influenced the resulting score. Although these findings do not alter the administration or scoring of the OPAT, they do provide a valuable reference in the event of future inquiries regarding the development of the OPAT.

General & Internal Medicine↗

Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

Spiering, Barry A.↗

Development of an Integrated Countermeasure Device for Use in Long-Duration Space Flight

Prolonged weightlessness is associated with declines in musculoskeletal, cardiovascular, and sensorimotor health. Consequently, in-flight countermeasures are required to preserve astronaut health. We developed and tested a novel exercise countermeasure device (CCD) for use in spaceflight with the aim of preserving musculoskeletal and cardiovascular health along with an incorporated balance-training component. Additionally, the CCD features a compact footprint, and a low power requirement. Methods: After design and development of the CCD, we carried out a training study to test its ability to improve cardiovascular and muscular fitness in healthy volunteers. Fourteen male and female subjects (41.4+/-9.0 years, 69.5+/-15.4Kg) completed 12 weeks (3 sessions per week) of concurrent strength and endurance training on the CCD. Subjects were tested at baseline and after 12 weeks for 1-repetition max leg press strength (1RM), peak oxygen consumption (VO2peak), and isokinetic joint torque (ISO) at the hip, knee, and ankle. Additionally, we evaluated subjects after 6 weeks of training for changes in VO2peak and 1RM. Results: VO2peak and 1RM improved after 6-weeks, with additional improvements after 12 weeks (1.95+/-0.5, 2.28+/-0.5, 2.47+/-0.6 LY/min and 131.2+/-63.9,182.8+/-75.0, 207.0+/-75.0 Kg) for baseline, 6 weeks, and 12 weeks respectively. ISO for hip adduction, adduction, and ankle plantar flexion improved after 12 weeks of training (70.3+/-39.5, 76.8+/-39.2 and 55.7+/-21.7 N-m vs. 86.1+/-37.3, 85.1+/-34.3 and 62.1+/-26.4 N-m respectively). No changes were observed for ISO during hip flexion, knee extension, or knee flexion. Conclusions: The CCD is effective at improving cardiovascular fitness and isotonic leg strength in healthy adults. Further, the improvement in hip adductor and abductor torque provides support that the CCD may provide additional protection for the preservation of bone health at the hip.

Streeper, Tim↗

Effects of Short- and Long-Duration Space Flight on Neuromuscular Function

The Functional Task Tests (FTT) is an interdisciplinary study designed to correlate the changes in functional tasks (such as emergency egress, ladder climbing, and hatch opening) with changes in neuromuscular, cardiovascular, and sensorimotor function. One aspect of the FTT, the neuromuscular function test, is used to investigate the neuromuscular component underlying changes in the ability of astronauts to perform functional tasks (representative of critical mission tasks) safely and quickly after flight. PURPOSE: To describe neuromuscular function after short- and long-duration space flight. METHODS: To date, 5 crewmembers on short-duration (10- to 15-day) missions and 3 on long-duration missions have participated. Crewmembers were assessed 30 days before flight, on landing day (short-duration subjects only) and 1, 6, and 30 days after landing. The interpolated twitch technique, which utilizes a combination of maximal voluntary contractions and electrically evoked contractions, was used to assess the maximal voluntary isometric force (MIF) and central activation capacity of the knee extensors. Leg-press and bench-press devices were used to assess MIF and maximal dynamic power of the lower and upper body respectively. Specifically, power was measured during concentric-only ballistic throws of the leg-press sled and bench-press bar loaded to 40% and 30% of MIF respectively. RESULTS: Data are currently being collected from both Shuttle and ISS crewmembers. Emerging data indicate that measures of knee extensor muscle function are decreased with long-duration flight. DISCUSSION: The relationships between flight duration, neural drive, and muscle performance are of particular interest. Ongoing research will add to the current sample size and will focus on defining changes in muscle performance measures after long-duration space flight.

Buxton, Roxanne E.↗

Functional Task Test (FTT)

This slide presentation reviews the Functional Task Test (FTT), an interdisciplinary testing regimen that has been developed to evaluate astronaut postflight functional performance and related physiological changes. The objectives of the project are: (1) to develop a set of functional tasks that represent critical mission tasks for the Constellation Program, (2) determine the ability to perform these tasks after space flight, (3) Identify the key physiological factors that contribute to functional decrements and (4) Use this information to develop targeted countermeasures.

Bloomberg, Jacob J.↗

Using Maximal Isometric Force to Determine the Optimal Load for Measuring Dynamic Muscle Power

Maximal power output occurs when subjects perform ballistic exercises using loads of ~30-50% of one-repetition maximum (1-RM). However, performing 1-RM testing prior to power measurement requires considerable time, especially when testing involves multiple exercises. Maximal isometric force (MIF), which requires substantially less time to measure than 1-RM, might be an acceptable alternative for determining the optimal load for power testing. PURPOSE: To determine the optimal load based on MIF for maximizing dynamic power output during leg press and bench press exercises. METHODS: Twenty healthy volunteers (12 men and 8 women; mean +/- SD age: 31+/-6 y; body mass: 72 +/- 15 kg) performed isometric leg press and bench press movements, during which MIF was measured using force plates. Subsequently, subjects performed ballistic leg press and bench press exercises using loads corresponding to 20%, 30%, 40%, 50%, and 60% of MIF presented in randomized order. Maximal instantaneous power was calculated during the ballistic exercise tests using force plates and position transducers. Repeated-measures ANOVA and Fisher LSD post hoc tests were used to determine the load(s) that elicited maximal power output. RESULTS: For the leg press power test, six subjects were unable to be tested at 20% and 30% MIF because these loads were less than the lightest possible load (i.e., the weight of the unloaded leg press sled assembly [31.4 kg]). For the bench press power test, five subjects were unable to be tested at 20% MIF because these loads were less than the weight of the unloaded aluminum bar (i.e., 11.4 kg). Therefore, these loads were excluded from analysis. A trend (p = 0.07) for a main effect of load existed for the leg press exercise, indicating that the 40% MIF load tended to elicit greater power output than the 60% MIF load (effect size = 0.38). A significant (p . 0.05) main effect of load existed for the bench press exercise; post hoc analysis indicated that the effect of load on power output was: 30% > 40% > 50% = 60%. CONCLUSION: Loads of 40% and 30% of MIF elicit maximal power output during dynamic leg presses and bench presses, respectively. These findings are similar to those obtained when loading is based on 1-RM.

Spiering, Barry A.↗