Verification and validation of atmospheric transport models with the UF Training Reactor

The University of Florida Training Reactor (UFTR) is a 100-kW ARGONAUT type reactor with a unique design such that a large volume of air passes through the core, producing and releasing significant quantities of 41 Ar. Once released, the radioargon is dispersed throughout the atmosphere and decays by a 1294 keV gamma ray emission. This quantified, validated, and controlled 41 Ar plume can be utilized to verify and validate atmospheric transport models (ATMs). This is accomplished by coupling an ATM with MCNP and comparing the results to experimental measurements. For this study, an in-house developed Gaussian dispersion model and the EPA approved Gaussian model AERMOD were coupled with MCNP to simulate the results of a six hour measurement taken on May 8th, 2018. For the measurements and simulations, a grid of seven NaI detectors were placed in four different rooftop locations near the UFTR plume stack. With easterly winds dominating during the morning and early afternoon, both the measurement results and simulations displayed a higher 41 Ar photon count rate on the detectors west of the plume stack throughout the day. Overall, the AERMOD simulations produced better results when compared to the in-house model, particularly for the detectors placed east and west of the plume stack. While some of the AERMOD data showed a strong correlation with the measurements, the results remain inconsistent. Here, due to the varying accuracy of the simulation results, it is theorized that the relationship between measurement results and simulations will improve with the use of localized weather information or the utilization of non-Gaussian dispersion models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data fusion for a vision-aided radiological detection system: Calibration algorithm performance

In order to improve the ability to detect, locate, track and identify nuclear/radiological threats, the University of Florida nuclear detection community has teamed up with the 3D vision community to collaborate on a low cost data fusion system. The key is to develop an algorithm to fuse the data from multiple radiological and 3D vision sensors as one system. The system under development at the University of Florida is being assessed with various types of radiological detectors and widely available visual sensors. A series of experiments were devised utilizing two EJ-309 liquid organic scintillation detectors (one primary and one secondary), a Microsoft Kinect for Windows v2 sensor and a Velodyne HDL-32E High Definition LiDAR Sensor which is a highly sensitive vision sensor primarily used to generate data for self-driving cars. Each experiment consisted of 27 static measurements of a source arranged in a cube with three different distances in each dimension. The source used was Cf-252. The calibration algorithm developed is utilized to calibrate the relative 3D-location of the two different types of sensors without need to measure it by hand; thus, preventing operator manipulation and human errors. The algorithm can also account for the facility dependent deviation from ideal data fusion correlation. Use of the vision sensor to determine the location of a sensor would also limit the possible locations and it does not allow for room dependence (facility dependent deviation) to generate a detector pseudo-location to be used for data analysis later. Using manually measured source location data, our algorithm-predicted the offset detector location within an average of 20 cm calibration-difference to its actual location. Calibration-difference is the Euclidean distance from the algorithm predicted detector location to the measured detector location. The Kinect vision sensor data produced an average calibration-difference of 35 cm and the HDL-32E produced an average calibration-difference of 22 cm. Using NaI and He-3 detectors in place of the EJ-309, the calibration-difference was 52 cm for NaI and 75 cm for He-3. In conclusion, the algorithm is not detector dependent; however, from these results it was determined that detector dependent adjustments are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗