Search NASA⌕ Search

Engineering topics

Stahl, H. Philip

Publications and source records attributed to Stahl, H. Philip.

At least 217 records · Page 12

Multivariable Parametric Cost Model for Ground Optical: Telescope Assembly

A parametric cost model for ground-based telescopes is developed using multi-variable statistical analysis of both engineering and performance parameters. While diameter continues to be the dominant cost driver, diffraction limited wavelength is found to be a secondary driver. Other parameters such as radius of curvature were examined. The model includes an explicit factor for primary mirror segmentation and/or duplication (i.e. multi-telescope phased-array systems). Additionally, single variable models based on aperture diameter were derived.

Stahl, H. Philip↗

James Webb Space Telescope (JWST) Primary Mirror Material Selection

The James Webb Space Telescope (JWST) conducted a phase down select process via the Advanced Mirror System Demonstrator (AMSD) project to assess the Technology Readiness Level of various candidate mirror materials. This process culminated in the selection of Beryllium as the JWST primary mirror material. This paper outlines the mirror evaluation process, defines the selection criteria and summarizes the candidate mirror's performances.

Stahl, H. Philip↗

Mirror Requirements for SAFIR

Large-aperture lightweight low-cost cryogenic mirrors are an enabling technology for planned NASA far-infrared and sub-millimeter missions such as CMB-Pol, SAFIR and SPECS. This paper examines d e mirror requirements necessary to design, build and characterize mirror segments for large space telescopes operating at temperatures of less than 1OK. Such mirrors should be diffraction limited in the far-IR with an areal density of less than 10 kg/sq m, aperture of 1 to 2 meters and cost of less than $500,000 per square meter.

Stahl, H. Philip↗

Ground-Based Telescope Parametric Cost Model

A parametric cost model for ground-based telescopes is developed using multi-variable statistical analysis, The model includes both engineering and performance parameters. While diameter continues to be the dominant cost driver, other significant factors include primary mirror radius of curvature and diffraction limited wavelength. The model includes an explicit factor for primary mirror segmentation and/or duplication (i.e.. multi-telescope phased-array systems). Additionally, single variable models based on aperture diameter are derived. This analysis indicates that recent mirror technology advances have indeed reduced the historical telescope cost curve.

Stahl, H. Philip↗

Cryogenic Test Results of Hextek Mirror

A 250 mm diameter lightweight borosilicate mirror has been interferometrically tested from room-temperature down to 30 K at the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The minor blank was manufactured by Hextek Corporation using a high-temperature gas fusion process and was then polished at MSFC. It is a sandwich-type mirror consisting of a thin face-sheet (approx.1.5 mm thick), a core structure (20 mm thick, approx.43 mm diameter cells, & 0.5-1.2 mm thick walls), and a thin back-sheet (3 mm thick). The mirror has a 2500 mm spherical radius-of- curvature @/lo). The areal density is 14 kg/sq m. The mirror was tested in the 1 m x 2 m chamber using an Instantaneous Phase Interferometer (PI) from ADE Phase Shift Technologies. The mirror was tested twice. The first test measured the change in surface figure from ambient to 30 K and the repeatability of the change. An attempt was then made by QED Technologies to cryo-figure the mirror using magnetorheological finishing. The second test measured the effectiveness of the cryo- figuring. This paper will describe the test goals, the test instrumentation, and the test results for these cryogenic tests.

Hadaway, James↗

Future Space Telescope Mirror Technology Requirements

Large-aperture lightweight space mirrors are critical for future NASA space science missions. This presentation summaries the optical minor requirements necessary to enable several planned missions.

Stahl, H. Philip↗

Helium Cryo Testing of a SLMS(TM) (Silicon Lightweight Mirrors) Athermal Optical Assembly

SLMS (TM) a thermal technology has been demonstrated in the small 4-foot helium cryogenic test chamber located at the NASA/MSFC X-Ray Calibration Facility (XRCF). A SLMS (TM) Ultraviolet Demonstrator Mirror (UVDM) produced by Schafer under a NASA/MSFC Phase I SBIR was helium cryo tested both free standing and bonded to a Schafer designed prototype carbon fiber reinforced silicon carbide (Cesic) mount. Surface figure data was obtained with a test measurement system that featured an Instantaneous Phase Interferometer (IPI) by ADE Phase Shift. The test measurement system s minimum resolvable differential figure deformation and possible contributions from test chamber ambient to cryo window deformation are under investigation. The free standing results showed differential figure deformation of 10.4 nm rms from 295K to 27K and 3.9 nm rms after one cryo cycle. The surface figure of the UVDM degraded by lambda/70 rms HeNe once it was bonded to the prototype Cesic mount. The change was due to a small astigmatic aberration in the rototype Cesic mount due to lack of finish machining and not the bonding technique. This effect was seen in SLMST (TM) optical assembly results, which showed differential figure deformation of 46.5 nm rms from 294K to 27K, 42.9 nm rms from 294K to 77K, 28.0 nm rms from 294K to 193K and 6.2 nm rms after one cryo cycle.

Jacoby, Marc T.↗

Optics Needs for Future NASA Missions

Present review of mirror technology required for planned future National Aeronautics and Space Administrative (NASA) missions, e.g. SAFIR, SWO, TPF, HHST, MTRAP, etc.

Stahl, H. Philip↗

Interferometer for Testing in Vibration Environments

Temporal phase shifting interferometers require a stable environment during the data acquisition, so that well controlled phase steps can be introduced between successively acquired interferograms. In contrast, single-frame interferometers need to acquire only one interferogram to provide a phase map with very good precision at high spatial resolution. Thus these interferometers are well suited for the interferometric testing of large optics with long radius of curvature for which vibration isolation is difficult, eg. testing astronomical telescope mirrors in a test tower, or testing space optics inside a cryogenic vacuum chamber. This paper describes the Instantaneous Phase Interferometer (IPI) by ADE Phase Shift, together with measurement results at NASA. The IPI consists of a polarization Twyman-Green interferometer operating at 632.8 nm, with single-frame data acquisition based on a spatial carrier technique. The spatial carrier fringes are generated by introducing large amount of tilt between the test beam and the reference beam. The phase information of the optical surface under test is encoded in the straightness of the interference fringes, which can be detected in a single frame with spatial sampling of 1000 x 1000 pixels. Measurements taken at the NASA Marshall Space Flight Cater in support of the characterization of developmental optics for the Next Generation Space Telescope are presented. Such tests consist of a mirror placed inside a cryogenic vacuum chamber, with the IPI placed outside the test chamber without any additional vibration isolation.

Eng, Ron↗

Status of NASA Mirror Technology Development for Large Space Telescopes

This paper presents the current status of several NASA technology development activities, including: Sub-scale Beryllium Mirror Demonstrator (SBMD), NGST (Next Generation Space Telescope) Mirror System Demonstrator (NMSD), Advanced Mirror System Demonstrator (AMSD), etc.. It also describes how these activities map into future NASA mission requirements, including: Next Generation Space Telescope (NGST), Single Aperture Far Infrared Observatory (SAFIR), Space Ultraviolet/Optical Observatory (SUVO), etc..

Stahl, H. Philip↗

New Cryogenic Optical Test Capability at Marshall Space Flight Center's Space Optics Manufacturing Technology Center

A new cryogenic optical testing capability exists at Marshall Space Flight Center's Space Optics Manufacturing Technology Center (SOMTC). SOMTC has been performing optical wavefront testing at cryogenic temperatures since 1999 in the X-ray Cryogenic Test Facility's (XRCF's) large vacuum chamber. Recently the cryogenic optical testing capability has been extended to a smaller vacuum chamber. This smaller horizontal cylindrical vacuum chamber has been outfitted with a helium-cooled liner that can be connected to the facility's helium refrigeration system bringing the existing kilowatt of refrigeration capacity to bear on a 1 meter diameter x 2 meter long test envelope. Cryogenic environments to less than 20 Kelvin are now possible in only a few hours. SOMTC's existing instruments (the Instantaneous Phase-shifting Interferometer (IPI) from ADE Phase-Shift Technologies and the PhaseCam from 4D Vision Technologies) view the optic under test through a 150 mm clear aperture BK-7 window. Since activation and chamber characterization tests in September 2001, the new chamber has been used to perform a cryogenic (less than 30 Kelvin) optical test of a 22.5 cm diameter x 127 cm radius of curvature SiO2 mirror, a cryogenic survival (less than 30 Kelvin) test of an adhesive, and a cryogenic cycle (less than 20 Kelvin) test of a ULE mirror. A vibration survey has also been performed on the test chamber. Chamber specifications and performance data, vibration environment data, and limited test results will be presented.

Kegley, Jeff↗

Analytical Verifications in Cryogenic Testing of NGST Advanced Mirror System Demonstrators

Ground based testing is a critical and costly part of component, assembly, and system verifications of large space telescopes. At such tests, however, with integral teamwork by planners, analysts, and test personnel, segments can be included to validate specific analytical parameters and algorithms at relatively low additional cost. This paper opens with strategy of analytical verification segments added to vacuum cryogenic testing of Advanced Mirror System Demonstrator (AMSD) assemblies. These AMSD assemblies incorporate material and architecture concepts being considered in the Next Generation Space Telescope (NGST) design. The test segments for workmanship testing, cold survivability, and cold operation optical throughput are supplemented by segments for analytical verifications of specific structural, thermal, and optical parameters. Utilizing integrated modeling and separate materials testing, the paper continues with support plan for analyses, data, and observation requirements during the AMSD testing, currently slated for late calendar year 2002 to mid calendar year 2003. The paper includes anomaly resolution as gleaned by authors from similar analytical verification support of a previous large space telescope, then closes with draft of plans for parameter extrapolations, to form a well-verified portion of the integrated modeling being done for NGST performance predictions.

Cummings, Ramona↗

Status of NASA Mirror Technology Development for Large Space Telescopes

This talk will present the current status of several NASA technology development activities, including: SBMD, NMSD, AMSD (Advanced Mirror System Demonstrator), etc.. And will discuss how these activities map into future NASA mission requirements, including: NGST (Next Generation Space Telescope), SAFIR, SUVO, etc.

Stahl, H. Philip↗

Overview of SBMD, NMSD and AMSD

For the past several years, NASA has conducted a coordinated mirror technology development program via SBIR's and contracts. This presentation provides a programmatic overview of three specific projects: SBMD (Subscale Beryllium Mirror Demonstrator), NMSD (NGST Mirror System Demonstrator) and AMSD (Advanced Mirror System Demonstrator). Specific emphasis will be given to technical constraints and objectives.

Stahl, H. Philip↗

IABG CSiC Mirror

CSiC has been proposed as a material for large cryogenic mirrors because of its unique material properties. However, there is limited experience in the cryogenic optical performance of CSiC mirrors. Therefore, a CSiC mirror was fabricated for NASA MSFC by IABG, polished by General Optics and cryogenic tested by MSFC in its XRCF. This presentation will review the history of this mirror and summarize the results of its cryogenic testing.

Stahl, H. Philip↗

COI Structural Analysis Presentation

This report discusses the structural analysis of the Next Generation Space Telescope Mirror System Demonstrator (NMSD) developed by Composite Optics Incorporated (COI) in support of the Next Generation Space Telescope (NGST) project. The mirror was submitted to Marshall Space Flight Center (MSFC) for cryogenic testing and evaluation. Once at MSFC, the mirror was lowered to approximately 40 K and the optical surface distortions were measured. Alongside this experiment, an analytical model was developed and used to compare to the test results. A NASTRAN finite element model was provided by COI and a thermal model was developed from it. Using the thermal model, steady state nodal temperatures were calculated based on the predicted environment of the large cryogenic test chamber at MSFC. This temperature distribution was applied in the structural analysis to solve for the deflections of the optical surface. Finally, these deflections were submitted for optical analysis and comparison to the interferometer test data.

Cline, Todd↗

Auburn Micrometeoroid Impact Test Data Analysis

This presentation provides an overview and summary of micrometeoroid impact testing performed by Auburn University and an analysis of the test results. The testing at Auburn utilized existing facilities at Auburn to generate hypervelocity impacts into multiple layers of thin Kapton films representative of the NASA concept for the NGST sunshield. The test data consists of impactor particle mass and velocity, and for each film layer, the number and size of holes generated by the initial impact and resulting impact debris. The analysis consists of combining the test data with existing impact effects models and the micrometeoroid environment at the L2 operating location of NGST to predict sunshield degradation.

Perrygo, Charles↗

AMSD Test Plan

NASA MSFC is the lead center on the Advanced Mirror System Demonstrator (AMSD) project and therefore has responsibility for testing each AMSD mirror to certify its compliance with the SOW. To accomplish this task it is necessary to accurately characterize each mirror's Radius of Curvature, Optical Axis Vertex Location, Conic Constant and Surface Figure Error. A key challenge is how to measure these parameters in the presence of gravity sag. This presentation will outline the MSFC/UAH team's proposed AMSD test plan.

Stahl, H. Philip↗