Effect of Space Telescope Primary Mirror Segment Errors on Coronagraph Instrument Performance
No abstract available
Advanced Mirror Technology Development (AMTD) Thermal Trade Studies
No abstract available
Advanced Mirror Technology Development (AMTD) Thermal Trade Studies
Advanced Mirror Technology Development (AMTD) is being done at Marshall Space Flight Center (MSFC) in preparation for the next Ultraviolet, Optical, Infrared (UVOIR) space observatory. A likely science mission of that observatory is the detection and characterization of 'Earth-like' exoplanets. Direct exoplanet observation requires a telescope to see a planet that is 10-10 times dimmer than its host star. To accomplish this using an internal coronagraph requires a telescope with an ultra-stable wavefront. This paper investigates two topics: 1) parametric relationships between a primary mirror's thermal parameters and wavefront stability, and 2) optimal temperature profiles in the telescope's shroud and heater plate that minimize static wavefront error (WFE) in the primary mirror.
Integration of Mirror Design with Suspension System Using NASA's New Mirror Modeling Software
No abstract available
The Geospace Dynamics Observatory; A Paradigm Changing Geospace Mission
The Geospace Dynamics Observatory (GDO) mission observes the near-Earth region in space called Geospace with unprecedented resolution, scale and sensitivity. At a distance of 60 Earth Radii (Re) in a near-polar circular orbit and a approx. 27-day period, GDO images the earth's full disk with (1) a three-channel far ultraviolet imager, (2) an extreme ultraviolet imager of the plasmasphere, and (3) a spectrometer in the near to far ultraviolet range that probes any portion of the disk and simultaneously observes the limb. The exceptional capabilities of the GDO mission include (1) unprecedented improvement in signal to noise for globalscale imaging of Earth's space environment that enable changes in the Earth's space environment to be resolved with orders of magnitude higher in temporal and spatial resolution compared to existing data and other approaches, and (2) unrivaled capability for resolving the temporal evolution, over many days, in local time or latitude with a continuous view of Earth's global-scale evolution while simultaneously capturing the changes at scales smaller than are possible with other methods. This combination of new capabilities is a proven path to major scientific advances and discoveries. The GDO mission (1) has the first full disk imagery of the density and composition variability that exist during disturbed "storm" periods and the circulation systems of the upper atmosphere, (2) is able to image the ionosphere on a global and long time scale basis, (3) is able to probe the mechanisms that control the evolution of planetary atmospheres, and (4) is able to test our understanding of how the Earth is connected to the Sun. This paper explores the optical and technical aspects of the GDO mission and the implementation strategy. Additionally, the case will be made that GDO addresses a significant portion of the priority mission science articulated in the recent Solar and Space Physics Decadal Survey.
Next-Generation Lightweight Mirror Modeling Software
The advances in manufacturing techniques for lightweight mirrors, such as EXELSIS deep core low temperature fusion, Corning's continued improvements in the Frit bonding process and the ability to cast large complex designs, combined with water-jet and conventional diamond machining of glasses and ceramics has created the need for more efficient means of generating finite element models of these structures. Traditional methods of assembling 400,000 + element models can take weeks of effort, severely limiting the range of possible optimization variables. This paper will introduce model generation software developed under NASA sponsorship for the design of both terrestrial and space based mirrors. The software deals with any current mirror manufacturing technique, single substrates, multiple arrays of substrates, as well as the ability to merge submodels into a single large model. The modeler generates both mirror and suspension system elements, suspensions can be created either for each individual petal or the whole mirror. A typical model generation of 250,000 nodes and 450,000 elements only takes 5-10 minutes, much of that time being variable input time. The program can create input decks for ANSYS, ABAQUS and NASTRAN. An archive/retrieval system permits creation of complete trade studies, varying cell size, depth, and petal size, suspension geometry with the ability to recall a particular set of parameters and make small or large changes with ease. The input decks created by the modeler are text files which can be modified by any editor, all the key shell thickness parameters are accessible and comments in deck identify which groups of elements are associated with these parameters. This again makes optimization easier. With ANSYS decks, the nodes representing support attachments are grouped into components; in ABAQUS these are SETS and in NASTRAN as GRIDPOINT SETS, this make integration of these models into large telescope or satellite models possible
Poco Graphite Inc. SuperSiC 0.25m Mirror Cryogenic Test Result
SuperSiC, a low areal density material, developed by POCO Graphite, have been used as mirror substrate for high energy lasers, laser radar systems, surveillance, telescopes, scan mirrors and satellites. SuperSiC has excellent thermal properties and cryogenic stability. It exhibits exceptional polishability for reflective optics with high strength, stiffness, and excellent thermal conductivity. A lightweighted 0.2-diameter polished SuperSic mirror was tested at cryogenic temperature at NASMSFC. Optical test results showed 6nm cry0 deformation from ambient to 30 degrees Kelvin and little to no change in its surface figure due to cry0 cycling.
AMSD Test Plan
The overall government plan to verify compliance of AMSD mirror systems to the specifications as given in the contract Statement of Work will be presented. The plan will address test requirements, test hardware, AMSD-XRCF interfacing, government vs contractor responsibilities, tests to be carried out, test conduction, and test data reduction & reporting. Issues regarding input to the plan and schedule of plan milestones will also be addressed.
MSFC Test Results for Selected Mirrors: Brush-Wellman/Goodrich 0.5 meter Joined-Beryllium Mirror; IABG 0.5 meter C/SiC Mirror; Xinetics 0.5 meter SiC Mirror; and Kodak 0.23 meter SiO2 Mirror
The results of cryo tests performed at the XRCF on the above mirrors will be presented. Each mirror was tested from room-temperature to around 30 K. The first three were tested together on a 3-mirror stand in the large chamber using the PhaseCam interferometer, while the Kodak mirror was tested in the small chamber using the EPI interferometer.
MSFC/Ball Space-Act Test Results of SBMD
The results of two cryo tests of the SBMD that were funded by Ball Aerospace through a Space-Act Agreement with MSFC will be discussed. These tests followed the formal completion of the SBMD program. The PhaseCam interferometer, rather than the Wavescope Shack-Hartmann sensor, was used during these tests.
AMSD Reaction Structure Cryo Deformation Test Plan
The method developed for measuring both in-plane & out-of-plane cryo deformations of AMSD reaction structures at the XRCF will be presented. For in-plane measurements, a theodolite is used to track the positions of several (up to ten) targets on the reaction structure. For out-of-plane measurements, the Leica ADM is used to measure the change in distance to several (up to ten) corner cubes attached to the reaction structure.
AMSD Figure Certification Plan
The method planned for the surface figure error measurement of the AMSDs at the XRCF will be discussed. Alignment, surface figure measurement, gravity effects, vibration & temperature environment effects, total error analysis, and data output will be discussed.
COI NMSD Hybrid Mirror
This presentation provides an overview of the development of the 1.6 meter hybrid mirror demonstrator for the NGST Mirror System Demonstrator (NMSD) program. The COI design approach for the NGST program combines the optical performance of glass, with the high specific stiffness capabilities of composite materials The foundation technologies being exploited in the development of the hybrid mirror focus upon precision Composite Materials for cryogenic operation, and non-contact optical processing (ion figuring) of the lightweight mirror surface. The NGST Mirror System Demonstrator (NMSD) has been designed and built by Composite Optics, Inc. (COI) with optical processing performed by SAGEM (REOSC). The sponsors of these efforts are the NASA Marshall and Goddard Space Flight Centers.
Managing Risk on a Technology Development Project/Advanced Mirror System Demonstrator
The risk management study applied to the Advanced Mirror System Demonstrator (AMSD), a precursor mirror technology development for the Next Generation Space Telescope (NGST) is documented. The AMSD will be developed as a segment of a lightweight primary mirror system that can be produced at a low cost and with a short manufacturing schedule. The technology gained from the program will support the risk mitigation strategy for the NGST, as well as other government agency space mirror programs.
MSFC/UAH Full Aperture Cryo-Figure AMSD Modal Characterization
A full-aperture, interferometric method for measuring the modal characteristics of the Advanced Mirror System Demonstrators (AMSDs) will be presented. The method involves stroboscopic surface figure measurement using an interferometer capable of simultaneous phase-shift measurements. Results of bread-board experiments will be presented as well as the plan for cryo measurements of the AMSDs.
Cryogenic Optical Testing at the Marshall Space Flight Center
Optical test results of several lightweight mirrors using different instruments will be presented. Several optical figure-testing techniques were used to overcome the vibration problem associated with optical testing with long optical path length.