Fractal Morphology, Imaging and Mass Spectrometry of Single Aerosol Particles in Flight
Abstract Not Provided
Engineering topics
Publications and source records attributed to Starodub, D..
Abstract Not Provided
Abstract Not Provided
This deposition includes the diffraction images generated by the paired polystyrene spheres in random orientations. These images were used to determine and phase the single particle diffraction volume from their autocorrelation functions.
Explore the source record for details and available documents.
Diffraction from the individual molecules of a molecular beam, aligned parallel to a single axis by a strong electric field or other means, has been proposed as a means of structure determination of individual molecules. As in fiber diffraction, all the information extractable is contained in a diffraction pattern from incidence of the diffracting beam normal to the molecular alignment axis. The limited size of the object results in continuous diffraction patterns characterized by neither Bragg spots nor layer lines. Equations relating the scattered amplitudes to the molecular electron density may be conveniently formulated in terms of cylindrical harmonics. For simulated diffraction patterns from short C nanotubes aligned along their axes, iterative solution of the equation for the zeroth-order cylindrical harmonic and its inverse with appropriate constraints in real and reciprocal space enables the phasing of the measured amplitudes, and hence a reconstruction of the azimuthal projection of the molecule.
We investigate the molecular structure information contained in the x-ray diffraction patterns of an ensemble of rigid CF{sub 3}Br molecules aligned by an intense laser pulse at finite rotational temperature. The diffraction patterns are calculated at an x-ray photon energy of 20 keV to probe molecular structure at angstrom-scale resolution. We find that a structural reconstruction algorithm based on iterative phase retrieval fails to extract a reliable structure. However, the high atomic number of Br compared with C or F allows each diffraction pattern to be treated as a hologram. Using this approach, the azimuthal projection of the molecular electron density about the alignment axis may be retrieved.
X-ray diffraction microscopy (XDM) is a new form of x-ray imaging that is being practiced at several third-generation synchrotron-radiation x-ray facilities. Nine years have elapsed since the technique was first introduced and it has made rapid progress in demonstrating high-resolution three-dimensional imaging and promises few-nm resolution with much larger samples than can be imaged in the transmission electron microscope. Both life- and materials-science applications of XDM are intended, and it is expected that the principal limitation to resolution will be radiation damage for life science and the coherent power of available x-ray sources for material science. In this paper we address the question of the role of radiation damage. Here, we use a statistical analysis based on the so-called "dose fractionation theorem" of Hegerl and Hoppe to calculate the dose needed to make an image of a single life-science sample by XDM with a given resolution. We find that for simply-shaped objects the needed dose scales with the inverse fourth power of the resolution and present experimental evidence to support this finding. To determine the maximum tolerable dose we have assembled a number of data taken from the literature plus some measurements of our own which cover ranges of resolution that are not well covered otherwise. The conclusion of this study is that, based on the natural contrast between protein and water and "Rose-criterion" image quality, one should be able to image a frozen-hydrated biological sample using XDM at a resolution of about 10 nm.