Search NASA⌕ Search

Engineering topics

Steele, Charles R.

Publications and source records attributed to Steele, Charles R..

Influence of increased mechanical loading by hypergravity on the microtubule cytoskeleton and prostaglandin E2 release in primary osteoblasts

Cells respond to a wide range of mechanical stimuli such as fluid shear and strain, although the contribution of gravity to cell structure and function is not understood. We hypothesized that bone-forming osteoblasts are sensitive to increased mechanical loading by hypergravity. A centrifuge suitable for cell culture was developed and validated, and then primary cultures of fetal rat calvarial osteoblasts at various stages of differentiation were mechanically loaded using hypergravity. We measured microtubule network morphology as well as release of the paracrine factor prostaglandin E2 (PGE2). In immature osteoblasts, a stimulus of 10x gravity (10 g) for 3 h increased PGE2 2.5-fold and decreased microtubule network height 1.12-fold without affecting cell viability. Hypergravity (3 h) caused dose-dependent (5-50 g) increases in PGE2 (5.3-fold at 50 g) and decreases (1.26-fold at 50 g) in microtubule network height. PGE2 release depended on duration but not orientation of the hypergravity load. As osteoblasts differentiated, sensitivity to hypergravity declined. We conclude that primary osteoblasts demonstrate dose- and duration-dependent sensitivity to gravitational loading, which appears to be blunted in mature osteoblasts.

Hypergravity↗

Effect of High Impact or Non-impact Loading Activity on Bone Bending Stiffness and Mineral Density

Material properties of conical bone, including mineral density (BMD) and its geometry is closely related to its load-carrying capacity. These two primary components determine the strength of conical bone. High impact loading involving acceleration and deceleration movements used in gymnastics induce higher BMD of the affected bone compared to the non-impact acceleration and deceleration movements used in swimming. Study of these two groups of athletes on bone bending stiffness has not been reported. The purpose of this study was to compare differences in bone bending stiffness and BMD between competitive female synchronized swimmers and female gymnasts. Thirteen world class female synchronized swimmers (SYN) and 8 female gymnasts (GYM), mean age 21 +/- 2.9 yr. were recruited for this study. We used a mechanical response tissue analyzer (Gaitscan, NJ) to calculate EI, where E is Young's modulus of elasticity and I is the cross-sectional moment of inertia. EI was obtained from tissue response to a vibration probe placed directly on the skin of the mid-region of tibia and ulna. BMD of the heel and wrist were measured with a probe densitometer (PIXI, Lunor, WI). The SYN were taller than (p < 0.05) the GYM but weighed the same as the GYM. EI obtained from tibia and ulna of the SYN (291 +/- 159 and 41 +/- 19.4, respectively) were not significantly different from thc GYM (285 +/- 140 and 44 +/- 18.3, respectively). BMD of the heel and wrist in GYM were higher than in SYN (p < 0.001). High impact weight-bearing activities promote similar bone strength but greater BMD response than non-impact activities performed in a buoyant environment.

Liang, Michael T. C.↗

Osteoblast Differentiation Decreases Hypergravity-Stimulated Release of PGE(sub 2)

We determined if progressive differentiation of osteoblasts influences their sensitivity to gravitational loading. Osteoblasts were cultured for 4 days (confluent monolayer), 6 days (prenodules), 9 days (nodules) and 19 days (mineralized nodules), then centrifuged at 10 times gravity (g) or 50-g for 3 hours using the NASA Ames 1-ft. Diameter Centrifuge. Stationary controls were placed in an adjacent incubator. Following centrifugation, conditioned media were collected and analyzed for PGE, by ELISA. Microtubules were fluorescently labeled and analyzed by confocal microscopy to determine microtubule network morphology and height. Centrifugation at 10-g reduced microtubule network height by 15% on d4 and 10% on d6, with variable changes in more mature cultures. No major changes in microtubule morphology were observed. PGE(sub 2) release by d4 cultures increased in a dose-dependent fashion (3-fold at 10-g and 6-fold at 50-g relative to controls). D6 cultures produced a 5-fold increase for both 10-g and 50-g. PGE(sub 2) increased only 1.5-fold by d9, and by d19, PGE(sub 2) was not delectable in either the control or hypergravity-stimulated cells. Thus, as osteoblasts differentiate in culture, responsiveness of the microtubule cytoskeleton and the PGE(sub 2) pathway to hypergravity declines.

Searby, Nancy D.↗

Structural Modeling of an Osteoblast Subjected to Hypergravity Loading

Osteoblasts, the bone-forming cells, are sensitive to altered mechanical loads such as those induced by fluid shear forces and cyclic uniaxial tension and compression. The cytoskeleton is thought to play an important role in a cell's response to mechanical loading and to coordinate cell shape changes. While some theoretical calculations indicate that a cell should not be able to respond to relatively small changes in gravity given the magnitude of forces exerted by intracellular components, osteoblasts have been shown to respond to microgravity. In this study, we investigated whether an osteoblast can sense a constant hypergravity acceleration of 10G. We asked if this load changes the shape of an osteoblast, and if engineering modeling accurately predicts the shape change. We modeled a cell by representing it as a series of axisymmetric shell structures. To test this model empirically, we performed experiments with cultured osteoblasts to measure changes in cell shape resulting from hypergravity loading.

Globus, Ruth K.↗

Thresholds for the perception of whole-body linear sinusoidal motion in the horizontal plane

An improved linear sled has been developed to provide precise motion stimuli without generating perceptible extraneous motion cues (a noiseless environment). A modified adaptive forced-choice method was employed to determine perceptual thresholds to whole-body linear sinusoidal motion in 25 subjects. Thresholds for the detection of movement in the horizontal plane were found to be lower than those reported previously. At frequencies of 0.2 to 0.5 Hz, thresholds were shown to be independent of frequency, while at frequencies of 1.0 to 3.0 Hz, thresholds showed a decreasing sensitivity with increasing frequency, indicating that the perceptual process is not sensitive to the rate change of acceleration of the motion stimulus. The results suggest that the perception of motion behaves as an integrating accelerometer with a bandwidth of at least 3 Hz.

Mah, Robert W.↗