Long-term Evolution of Upper Stratospheric Ozone at Selected Stations of the Network for the Detection of Stratospheric Change (NDSC)

The long-term evolution of upper stratospheric ozone has been recorded by lidars and microwave radiometers within the ground-based Network for the Detection of Stratospheric Change (NDSC), and by the space-borne Solar Backscatter Ultra-Violet instruments (SBUV), Stratospheric Aerosol and Gas Experiment (SAGE), and Halogen Occultation Experiment (HALOE). Climatological mean differences between these instruments are typically smaller than 5% between 25 and 50 km. Ozone anomaly time series from all instruments, averaged from 35 to 45 km altitude, track each other very well and typically agree within 3 to 5%. SBUV seems to have a slight positive drift against the other instruments. The corresponding 1979 to 1999 period from a transient simulation by the fully coupled MAECHAM4-CHEM chemistry climate model reproduces many features of the observed anomalies. However, in the upper stratosphere the model shows too low ozone values and too negative ozone trends, probably due to an underestimation of methane and a consequent overestimation of ClO. The combination of all observational data sets provides a very consistent picture, with a long-term stability of 2% or better. Upper stratospheric ozone shows three main features: (1) a decline by 10 to 15% since 1980, due to chemical destruction by chlorine; (2) two to three year fluctuations by 5 to 10%, due to the Quasi-Biennial Oscillation (QBO); (3) an 11-year oscillation by about 5%, due to the 11-year solar cycle. The 1979 to 1997 ozone trends are larger at the southern mid-latitude station Lauder (45 S), reaching 8%/decade, compared to only about 6%/decade at Table Mountain (35 N), Haute Provence/Bordeaux (approximately equal to 45 N), and Hohenpeissenberg/Bern(approximately equal to 47 N). At Lauder, Hawaii (20 N), Table Mountain, and Haute Provence, ozone residuals after subtraction of QBO- and solar cycle effects have levelled off in recent years, or are even increasing. Assuming a turning point in January 1997, the change of trend is largest at southern mid-latitude Lauder, +11%/decade, compared to +7%/decade at northern mid-latitudes. This points to a beginning recovery of upper stratospheric ozone. However, chlorine levels are still very high and ozone will remain vulnerable. At this point the most northerly mid-latitude station, Hohenpeissenberg/Bern differs from the other stations, and shows much less clear evidence for a beginning recovery, with a change of trend in 1997 by only +3%/decade. In fact, record low upper stratospheric ozone values were observed at Hohenpeissenberg/Bern, and to a lesser degree at Table Mountain and Haute Provence, in the winters 2003/2004 and 2004/2005.

Steinbrecht, W.↗

The NDSC ozone and temperature lidar alogorithm intercomparison ubutuatuve (A2I): project overview

In September 2003, the Lidar Working Group (LWG) of the Network for Detection of Stratospheric Change (NDSC) initiated an extensive project to compare the ozone and temperature algorithms used within NDSC. This initiative, referred to later as Algorithm Intercomparison Initiative (A2I), uses simulated lidar signals to test and compare various parts of the ozone and temperature lidar algorithms. In addition to the fact that it meets the requirement of the NDSC protocols, this exercise allows the detailed assessment, by all the participants, of some of the sources and magnitudes of various uncertainties associated with the algorithms, and/or with the theoretical assumptions made in these algorithms. The outcome of the A21 is to try to find common grounds in the way ozone and temperature can be retrieved in order to reduce and possibly eradicate discrepancies due to algorithm issues alone. Specific issues such as homogenizing the choice of Rayleigh extinction cross-sections, ozone absorption cross-sections, a priori information, and the definition of the vertical resolutions are among the primary targets of the A21 outcome.

lidar↗

Results of the NY-Alesund ozone measurements intercomparison NAOMI

Worldwide, about ten Differential Absorption Lidars are used for long-term monitoring of stratospheric ozone. These systems are an important component of the Network for the Detection of Stratospheric Change. Although DIALs are self-calibrating in principle, regular intercomparisons with other ozone-lidars, microwave radiometers or ozone-sondes are highly desirable to ensure high data quality at a well known level. The Network for the Detection of Stratospheric Change (NDSC) validation policy suggests that such intercomparisons be "blind", meaning all participants submit their data to an impartial referee, without seeing results from the other participants. Here we report on the "blind" intercomparison taking place from January 20th to February 10th 1998 at Ny-Alesund, Spitsbergen (78.92 deg N, 11.95 deg E). Participating groups were from the Alfred Wegener Institute, Potsdam, operating the NDSC DIAL system at Ny-Alesund, from the University of Bremen operating the NDSC microwave radiometer for ozone profiling at Ny-Alesund, and the NASA Goddard Space Flight Center group with the "NDSC travelling standard" STROZ-LITE. The first author acted as the impartial referee. Also used for the intercomparison were data from ECC-6A/Vaisala RS80 ozone sondes routinely launched at Ny-Alesund by the AWI group. A 1% KI solution (3 ml) and the 1986 ECC pump correction (1.092 at 5 hPa) are used. The ECC-data were available to all participants during the campaign and thus were not "blind". Table 1 summarizes the expected performance of the instruments participating in the ozone intercomparison reported in this paper.

Steinbrecht, W.↗

The Ny-Alesund aerosol and ozone measurements intercomparison campaign 1997/1998 (NAOMI-1998)

An intercomparison campaign for Lidar measurements of stratospheric ozone and aerosol has been conducted at the Primary Station of the Network for the Detection of Stratospheric Change (NDSC) in Ny-Alesund/Spitsbergen during January-February 1998. In addition to local instrumentation, the NDSC mobile ozone lidar from NASA/GSFC and the mobile aerosol lidar from Alfred Wegener Institute (AWI) participated. The aim is the validation of stratospheric ozone and aerosol profile measurements according to NDSC guidelines. This paper briefly presents the employed instruments and outlines the campaign. Results of the blind intercomparison of ozone profiles are given in a companion paper and temperature measurements are described in this issue.

Neuber, R.↗

Correcting for Interference of Mt. Pinatubo Aerosols on DIAL Measurements of Stratospheric Ozone

Since March 1991 our group has been routinely operating a Differential Absorption Lidar system in Toronto, Canada. The system is based on a XeCl Excimer laser and the main system parameters are reported. In all measurements after July 21, 1991 we have observed aerosol layers in the stratosphere, resulting from the Mt. Pinatubo eruptions around June 15, 1991. These aerosol layers have increased in size since they were first observed and backscatter ratios of more than 5 to 353 nm have been observed. They interfere significantly with any optical ozone measurement. In this paper we will describe our work to quantify the effects of the additional aerosol on differential absorption measurements and the attempt to correct for them.

Steinbrecht, W.↗

Two Wavelength Measurements of the Pinatubo Aerosol Above Toronto, Canada

Since March 1991 our group has been routinely operating a Differential Absorption Lidar system in Toronto, Canada. The system is based on a XeCl Excimer laser. We have also been running a Backscatter Lidar based on a NdYAG laser. In the period from March 1991 to March 1992 measurements have been taken during about 40 nights with the DIAL system and more than 90 nights with the NdYAG system. In all measurements after July 21, 1991 we have observed aerosol layers in the stratosphere, resulting from the Mt. Pinatubo eruptions around June 15, 1992. These aerosol layers interfere significantly with many optical remote sensing techniques, and we have been investigating their properties with our two Lidar systems. In this paper we present a summary of these measurements.

Steinbrecht, W.↗

Lidar Studies of Clouds at Toronto During the ECLIPS Program

The Experimental Cloud Lidar Pilot Study (ECLIPS) measurement program involves the measurement of cloud optical and physical parameters with vertically pointing ground-based lidars simultaneously with satellites observing the same cloud system from above. Our frequency doubled Nd:YAG lidar transmits about 500 mJ of linearly polarized radiation at each wavelength (532, 1064 nm) with a prf of 20 Hz. An overview of the statistical behavior of cloud physical parameters and optical parameters is presented.

Pal, S. R.↗