Search NASASearch

Engineering topics

Steininger, H.

Publications and source records attributed to Steininger, H..

Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC

Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.

47 OTHER INSTRUMENTATION

Beam test performance studies of CMS Phase-2 Outer Tracker module prototypes

A new tracking detector will be installed as part of thePhase-2 upgrade of the CMS detector for the high-luminosity LHC era.This tracking detector includes the Inner Tracker, equipped withsilicon pixel sensor modules, and the Outer Tracker, consisting ofmodules with two parallel stacked silicon sensors. The Outer Trackerfront-end ASICs will be able to correlate hits from chargedparticles in these two sensors to perform on-module discriminationof transverse momenta (p$_{T}$). The p$_{T}$information is generated at a frequency of 40 MHz and will be usedin the Level-1 trigger decision of CMS. Prototypes of theso-called 2S modules were tested at the Test Beam Facility at DESYHamburg between 2019 and 2020. These modules use the finalfront-end ASIC, the CMS Binary Chip (CBC), and for the firsttime the Concentrator Integrated Circuit (CIC), optical readoutand on-module power conversion. In total, seven modules were tested,one of which was assembled with sensors irradiated with protons. Animportant aspect was to show that it is possible to read out modulessynchronously. A cluster hit efficiency of about 99.75 % wasachieved for all modules. The CBC p$_{T}$ discriminationmechanism has been verified to work together with the CIC andoptical readout. The measured module performance meets therequirements for operation in the upgraded CMS tracking detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

MOMA: The Challenge to Search for Organics and Biosignatures on Mars

This paper describes strategies to search for, detect, and identify organic material on the surface and subsurface of Mars. The strategies described include those applied by landed missions in the past and those that will be applied in the future. The value and role of ESA's ExoMars rover and of her key science instrument Mars Organic Molecule Analyzer (MOMA) are critically assessed.

Goetz, Walter

It's a Trap! A Review of MOMA and Other Ion Traps in Space or Under Development

Since the Viking Program, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, including (from the inner to outer reaches): Venus (Pioneer); our moon (LADEE); Mars (Viking, Phoenix, and Mars Science Laboratory); and, Saturns largest moon Titan (Cassini-Huygens). More recently, however, ion trap mass spectrometer (ITMS) instruments have found a niche as smaller, versatile alternatives to traditional quadrupole mass analyzers, capable of in situ characterization of planetary environments and the search for organic matter. For example, whereas typical QMS systems are limited to a mass range up to 500 Da and normally require multiple RF frequencies and pressures of less than 10(exp -6) mbar for optimal operation, ITMS instruments commonly reach upwards of 1000 Da or more on a single RF frequency, and function in higher pressure environments up to 10(exp -3) mbar.

ion trap