Search NASA⌕ Search

Engineering topics

Stenson, E. V. (ORCID:0000000318681513)

Publications and source records attributed to Stenson, E. V. (ORCID:0000000318681513).

Diocotron modes in pure electron plasmas in the APEX levitating dipole trap

Abstract Observations of persistent toroidal modes in dipole-trapped pure electron plasmas are presented. Non-neutral electron plasmas were confined by the poloidal magnetic field of the APEX (A Positron Electron eXperiment) levitating dipole trap. The negative bias of the electron emitter was gated to control the filling time. Large amplitude, narrow-band oscillations were consistently observed in wall probe measurements after the fill. The oscillatory image-charge currents induced by the trapped electron plasma typically persisted for many seconds with fundamental frequencies, f 0 = 50 to 500 kHz, that scale with the E → × B → drift velocity. We attribute this feature to the dipole-equivalent of the diocotron mode that is commonly observed in non-neutral plasmas in linear traps.

Deller, A. (ORCID:0000000234301501)↗

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)↗

A buffer-gas trap for the NEPOMUC positron beam: optimization studies with electrons

Buffer-gas traps (BGTs) use inelastic interactions with nitrogen molecules to capture positrons from a continuous beam. These devices are invaluable for high-resolution studies of matter–antimatter interactions, antihydrogen research and positronium laser spectroscopy. We present a new project with the goal of producing a non-neutral plasma containing ${\sim }10^8$ low-energy positrons by installing a BGT on the NEPOMUC (NEutron induced POsitron source MUniCh) high-intensity positron beam. Details of the BGT are outlined and results are presented from experiments in which an electron beam, with a similar intensity and energy spread to the remoderated NEPOMUC beam, was used to create pulses of non-neutral electron plasma. The device is a vital component of the APEX (A Positron Electron eXperiment) project, which aims to create a low-temperature electron–positron pair plasma.

Physics↗

Annihilation-gamma-based diagnostic techniques for magnetically confined electron–positron pair plasma

Efforts are underway to magnetically confine electron–positron pair plasmas to study their unique behaviour, which is characterized by significant changes in plasma time and length scales, supported waves and unstable modes. However, use of conventional plasma diagnostics presents challenges with these low-density and annihilating matter–antimatter plasmas. To address this problem, we propose to develop techniques based on the distinct emission provided by annihilation. This emission exhibits two spatial correlations: the distance attenuation of isotropic sources and the back-to-back propagation of momentum-preserving 2 $\gamma$ annihilation. We present the results of our analysis of the $\gamma$ emission rate and the spatial profile of the annihilation in a magnetized pair plasma from direct pair collisions, from the formation and decay of positronium as well as from transport processes. In order to demonstrate the effectiveness of annihilation-based techniques, we tested them on annular $\gamma$ emission profiles produced by a $\beta ^+$ radioisotope on a rotating turntable. Direct and positronium-mediated annihilation result in overlapping volumetric $\gamma$ sources, and the 2 $\gamma$ emission from these volumetric sources can be tomographically reconstructed from coincident counts in multiple detectors. Transport processes result in localized annihilation where field lines intersect walls, limiters or internal magnets. These localized sources can be identified by the fractional $\gamma$ counts on spatially distributed detectors.

Physics↗