Search NASA⌕ Search

Engineering topics

Stephen B Jones

Publications and source records attributed to Stephen B Jones.

Simultaneous Focused Laser Differential Interferometry and High-Speed Schlieren in a Mach 6 Flow

An instrument is demonstrated that is capable of simultaneous and independent flow density fluctuation measurements over the same line-of-sight by combining two optical techniques: focused laser differential interferometry (FLDI) and high-speed schlieren (HSS). The FLDI instrument measures fluctuations at a single point in the flowfield at 10 MHz, with the resulting signal most sensitive in the region nearest the focal plane of the FLDI laser beam. The HSS instrument acquires images at 20 kHz along the same optical axis as the FLDI beam, but with the resulting signal path averaged over the entire HSS line-of-sight. The introduction of the HSS optics into the FLDI beam path provides two high-quality measurement capabilities in a single system with no degradation of performance relative to stand-alone FLDI or HSS instruments.

Focused Laser Differential Interferometry↗

Multi-Point Line Focused Laser Differential Interferometer for High-Speed Flow Fluctuation Measurements

A multi-point focused laser differential interferometer (FLDI) has been developed to measure density fluctuations at 16 points along a line. A pair of cylindrical lenses on the transmitter side of a conventional single-point FLDI instrument form two closely spaced (≤200 μm), orthogonally polarized, parallel laser lines at the instrument’s focus. On the receiver side of the instrument, the interference of the beams on a 16-element photodiode array results in a single line of measurements. The further addition of a Nomarski prism creates two separate measurement lines, and the addition of a second photodiode array to the instrument enables simultaneous measurements of density fluctuations along the two lines separated by several millimeters. These two lines of measurement can be conveniently oriented at any azimuthal angle relative to the instrument’s optical axis on the measurement plane, coinciding with the instrument’s focus. Two experiments were performed to demonstrate the capabilities of the instrument. In the first experiment, a laser-induced breakdown spark generated a traveling spherical shock wave, and measurements of the resulting density disturbance and wave velocity were obtained. These results were compared to high-speed schlieren images of the shock wave acquired at 400 kHz. In the second experiment, the multi-point FLDI instrument was used to measure density disturbances in the boundary layer of a flat plate in a Mach 6 freestream flow. The measurements were made along two lines, both approximately 6 mm in length, extending from the surface of the plate through the boundary layer. High-speed schlieren images were acquired at 100 kHz during separate wind tunnel runs at matching unit Reynolds numbers to visualize the unsteady boundary layer flow and compare to the FLDI measurements.

Laser beam shaping↗

High-Speed Schlieren Analysis of Retropropulsion Jet in Mach 10 Flow

High-speed schlieren imaging of a 5-in.-diam, 70° sphere-cone model with a single centerline 15° half-angle nozzle was performed in a Mach 10 flow. Image sequences captured at 100 kHz were obtained with the nozzle plugged (fully blunted model), no nozzle flow, and with nozzle flow over a range of supply pressures. The freestream unit Reynolds number was kept constant for all runs at3.38×106m−1. Time-average information pertaining to the location, width, and stand-off distance of the bow shock, interface, terminal shock, and triple point as a function of jet pressure ratio are presented based on analysis of covariance images from each run. Measurement of jet plume boundary shape as a function of jet pressure ratio is also presented. Analyses of frequency content associated with the jet structure are shown, as are results of the proper orthogonal decomposition of these data. For all runs with nozzle flow, a dominant fundamental frequency of 2 kHz was observed. Finally, a discussion of bow shock unsteadiness resulting from interaction with freestream disturbances for the blunted and no nozzle flow is provided, as is a discussion on the formation of weak waves emanating from the bow shock resulting from this interaction.

Brett F Bathel↗

Preparations for Tomographic Background-Oriented Schlieren Measurements in the 11-by 11-Foot Transonic Wind Tunnel

Efforts from a collaboration involving NASA’s Langley, Glenn, and Ames Research Centers to construct and test a tomographic background-oriented schlieren system in preparation for testing at the Ames 11-by 11-foot Transonic Wind Tunnel are discussed. To prepare for the test and to evaluate the probability of success, a mock-up of the tunnel test section was constructed at Langley. Schematics and renderings of the tunnel were used to place eight gigabit Ethernet CMOS cameras circumferentially around approximately 180° of the mock-up. Camera modules designed in-house were used to provide on-axis lighting to get maximum intensity return from the retroreflective backgrounds. A data acquisition system was designed to control the eight cameras and light sources with an acquisition rate of 4 Hz. A novel method for creation of the speckled background was developed for the test, enabling simple application and removal of the material on the tunnel walls. A tea light candle and a heat gun with two different nozzle shape attachments were used to provide an index of refraction gradient field to assess the quality of the 2D and tomographic results from the system. The heat gun was again used as an initial test article after the camera system had been set up at the Ames tunnel, giving similar results to those seen at the mock-up, and indicating a high probability of success for the testing campaign.

Joshua M. Weisberger↗

Progress on the Development of a Step Height Sensor for the BOLT Flight Vehicle

This presentation will summarize progress on the development of a step height sensor for the BOLT flight vehicle. Two methods have been proposed to measure the step size in this effort.The first method involves the application of miniaturized camera embedded in the flight vehicle that views the step through a rearward-facing port (shown in Fig. 1a inset). The second method involves the application of a linear fiber optic array bundle to measure the intensity of light reflected back from the aft body step (concept shown in Fig. 1b). Preliminary testing with the miniaturized camera has been performed in the lab and shows that displacements of ≤10 μm can be measured using this method. Final testing with both methods will be performed on the test stand shown in Fig. 1a. This test stand will include a fine adjustment vertical translation stage that will be used to adjust the step height in steps of 1-2 μm. A high-magnification imaging system will also be used to verify the step height. The miniaturized camera and linear fiber optic array bundle will be mounted in one of several port holes with varying degrees of inclination relative to the top surface in the opposing aft-section slab. BOLT flight vehicle details and information on the steps can be found in Ref. [1].

BOLT↗

Analysis of the Amplitude Response of a Two-Point and a Two-Line/Multi-Point Focused Laser Differential Interferometer

Experiments were performed with two different focused laser differential interferometer (FLDI) instruments to assess the amplitude response of each instrument to a traveling shock-wave generated by a laser spark. The first FLDI instrument generated two measurement points, with each measurement point providing sensitivity to density fluctuations induced by the shockwave. By performing a cross-correlation between the signals obtained from each measurement point, the phase velocity of density fluctuations can be obtained. The second FLDI instrument generated two measurement lines that are oriented either parallel or orthogonal to the shockwave direction of travel with the resulting interference pattern sampled at multiple equally-spaced points along each line. As a result, this instrument provides density fluctuation measurement capability at multiple points simultaneously. When the measurement lines are oriented parallel to the shockwave direction of travel, the phase velocity, rate of change of the phase velocity, and acceleration of density fluctuations traveling along each line can be obtained by performing a cross-correlation between points along a single line. When the measurement lines are oriented orthogonal to the shockwave direction of travel, the spatially-varying phase velocity can be obtained by performing a cross-correlation between points at the same relative location on each measurement line. Computations of the shockwave generated by the laser spark are used to simulate the response of each instrument and are compared to the experimental results. High-speed Schlieren imaging has also been performed and is compared with the FLDI measurements and computational results.

Focused Laser Differential Interferometer↗

Two-Line Focused Laser Differential Interferometry of a Flat Plate Boundary Layer at Mach 6

Cylindrical optics have been added to a conventional two-point focused laser differential interferometry (FLDI) system to make measurements of density fluctuations at multiple points along two lines. Optics fixed in rotation mounts allow for the two lines to be oriented in any position relative to each other to make measurements of different physical phenomena. The system was first characterized in the laboratory using a laser-induced breakdown spark to provide a well-defined density fluctuation. The system was then installed at the NASA Langley 20 Inch Mach 6 Air Tunnel to make measurements through the boundary layer of a flat plate model and in the tunnel free stream.

Joshua M Weisberger↗

Two-Line Focused Laser Differential Interferometry of a Flat Plate Boundary Layer at Mach 6

Flat plate models are often used in wind tunnel testing to make measurements of the boundary layer, but preclude the use of conventional focused laser differential interferometry (FLDI) measurements, particularly for measurements at the surface of the model. By instead focusing light in only one direction using cylindrical optics, as opposed to two directions using only spherical optics, FLDI measurements can be made without truncating the beam at the model edges. Measurements at discrete points along a line can also be acquired, effectively acting as many individual FLDI instruments in a single measurement. Here, a two-line FLDI system has been constructed that allows for the measurement lines to be easily oriented at any azimuthal angle about the optical axis since the optics are housed in rotation mounts. Velocity measurements at points along a line or between two lines are also possible, since the beams are split similar to the two-point FLDI instrument. The system was first characterized in the laboratory using a laser-induced breakdown spark to provide a well-defined density fluctuation, along with high-speed schlieren measurements for comparison. The system was then installed at the NASA Langley 20-Inch Mach 6 Air Tunnel to make measurements through the boundary layer of a flat plate model and in the tunnel freestream.

Joshua M Weisberger↗

Development of Optical Step Height Measurement Capability for the BOLT Flight Vehicle

This paper presents details on the development of testing procedures to evaluate two different optical step height sensors that were intended for use on the first and second Boundary Layer Transition (BOLT and BOLT II) flight vehicle as well as other flight vehicles. The accurate and precise measurement of step height at the interface of different sections of a flight vehicle is important, as small changes in the step height (in some instances < 10 microns) at such locations can have a significant influence on the development of a boundary layer over the outer surface of the vehicle, which in turn can significantly impact aeroheating (among other things). In this paper, testing procedures have been developed, and test hardware assembled, to determine the capabilities of two optical step height sensor candidates. The first candidate is a miniaturized camera sensor that would be embedded into the body of a flight vehicle and would image the interface between two sections of that vehicle. The second candidate is a small fiber-based optical sensor that would also be embedded into the body of the flight vehicle, but projects light onto the interface between two sections of the flight vehicle, and then monitors any reflected/scattered light from that interface. Preliminary data from these two sensor candidates are presented, and a discussion of improvements that will be made in the testing procedures and to the test hardware is provided.

Brett F Bathel↗

Preparations for Tomographic Background-Oriented Schlieren at the 31-Inch Mach 10 Wind Tunnel

This paper details effort by researchers at NASA Langley Research Center to prepare for an upcoming high-speed tomographic background-oriented schlieren test entry in the 31-Inch Mach 10 wind tunnel. In order to troubleshoot potential problems that will arise when setting up the experiment in the actual test facility, a full-scale mock-up of the 31-Inch Mach 10 wind tunnel test section was constructed in the laboratory to provide equivalent characteristic optical access and mounting options. A 3D-printed model that replicates the scale of the forebody of a supersonic retropropulsion (SRP) model that will be used in the final test entry has been fabricated with a central nozzle that can be connected to a high-pressure gas supply to approximate the nozzle flow that will occur. Six high-speed imaging systems consisting of a high-speed camera with a fiber illuminator module have been assembled and mounted on the test section mock-up to provide six unique perspective views of the nozzle flow from the model. Tests with one of the imaging systems using a pulsed laser light source showed that sufficient signal intensity and illumination uniformity was achieved, as demonstrated by the 2D BOS data obtained with the system. Additional work to show that retroreflective material would survive inside of the test section of the 31-Inch Mach 10 tunnel was also performed. Finally, a remotely-controlled tomographic BOS calibration system is discussed.

Brett F Bathel↗

Self-Aligned Focusing Schlieren at the 0.3-M Transonic Cryogenic Tunnel and the National Transonic Facility

The implementation of a self-aligned focusing schlieren (SAFS) system at two cryogenic wind tunnels at NASA Langley Research Center is discussed. Risk-reduction testing of the SAFS system was first performed at the 0.3-M Transonic Cryogenic Tunnel to evaluate the system’s operation in a small-scale characteristic cryogenic facility. Testing was conducted with three models: a three-quarter span 25.4-mm-diameter cylinder, a semi-span 65A006 tapered unswept airfoil, and a full-span SC(3)-0712 airfoil. Testing with the cylinder and semi-span airfoil revealed a highly dynamic shock environment, whereas the shock on the full-span airfoil was stationary, solidifying the usage of this model for a pre-/post-shock particle tracking velocimetry measurement. Temperature-induced polarization-altering window stresses were encountered during low-temperature testing and were mitigated using a “non-ideal” quartz/quartz Rochon prism that had largely been neglected since the SAFS system’s first introduction in favor of the more favorable “ideal” glass/quartz Rochon prism. The size of the SAFS system was then decreased in order to fit inside an environmentally controlled camera can enclosure at the National Transonic Facility (NTF) for testing of a sting-mounted aircraft model. The SAFS system was demonstrated to be effective at filtering out the large density gradient flow in the0.3-M plenum, and the thick, high density turbulent boundary layers on the wind tunnel walls at the NTF. Results of the testing campaigns and improvements to future systems are discussed.

Joshua M Weisberger↗