Search NASA⌕ Search

Engineering topics

Steutermann, Mark

Publications and source records attributed to Steutermann, Mark.

Scaleup and Site-Specific Engineering Design for Global Thermostat Direct Air Capture Technology

The overall goal of the project is completion of an initial design of a commercial-scale, Carbon Capture, Utilization, and Storage Direct Air Capture (CCUS-DAC) plant design at three different sites that captures a net of at least 100,000 tonnes per year (TPY) carbon dioxide (CO 2 ) from the atmosphere and considers compression and conditioning of the captured CO 2 for purpose of pipeline transportation to different geological formation sites for deep well injection and underground storage. In addition to the leading system consisting of a scaled-up Global Thermostat DAC unit, overall plant design includes a combined Heat and Power (CHP) unit integrated with a conventional liquid amine-based carbon capture system (90% capture) and compression facilities. These are considered balance of plant (BOP) systems and are required to provide low carbon-intensity steam and power to the DAC process. A second approach involving provision of DAC units modified to directly capture emissions from the CHP unit was initially assessed as an alternative and it was determined to be less mature than considered approach and not included in the scaled-up plant design efforts. Three geographically diverse continental United States locations were selected to better understand the effect of local/regional ambient conditions on scaled-up DAC system performance and project costs: Bucks, Alabama (hot wet climate), Odessa, Texas (dry hot climate), and Goose Creek, Illinois (mid continental climate). The team focused on initial engineering design activities, including the development of project design criteria, initiation of site-specific studies and investigations, completion of DAC system process and equipment design, and definition of balance of plant (BOP) engineering. The purpose of the activities were to develop Technoeconomic Analysis (TEA), Life-Cycle Analysis (LCA), and Environmental, Health, and Safety (EH&S) analysis, and Business Case Analysis (BCA) to validate that the project engineering and scale-up plans of the DAC systems, at each of the three distinct case studies considered, are technically, economically, and environmentally feasible for commercial-scale operation.

20 FOSSIL-FUELED POWER PLANTS↗

Direct Air Capture Case Studies

Presentation given by the National Energy Technology Laboratory's Tim Fout at the Carbon Intel Forum, September 2022 on the recent NETL Direct Air Capture Case Study reports.

Fout, Timothy↗

Direct Air Capture Case Studies: Solvent System

This case study provides cost and performance estimates for a solvent-based direct air capture (DAC) system at varying scales. The performance of the DAC system is largely based upon vendor performance while the costs of the system were developed as independently as possible. This study is representative of an example DAC system configuration and is not an optimized design.

42 ENGINEERING↗

Direct Air Capture Case Studies: Sorbent System

Poster presentation of NETL's recently-published DAC sorbent case study results at the 2022 NETL Carbon Management Project Review Meeting held on August 15-19, 2022 in Pittsburgh, PA.

Fout, Timothy↗

Direct Air Capture Case Studies: Sorbent System

This report serves as an independent assessment of the performance and cost of a generic sorbent-based direct air capture (DAC) system. The sorbent considered is not reflective of any one material type or functionalization approach; rather, it represents an approximate average of reported material performance in the literature. The system configuration represents what was judged to be the most reasonable configuration if these systems were to be deployed in the near term.

42 ENGINEERING↗