Search NASA⌕ Search

Engineering topics

Stevens, Robert W.

Publications and source records attributed to Stevens, Robert W..

Cooled Gas Turbine and Combined Cycle Analysis for NH 3 -CH 4 Fuel Mixes (Up to 100% NH 3 )

In this study, a cooled gas turbine (GT) analysis was conducted for varying levels of ammonia (NH 3 ) blends with methane. The ultimate goal is to have a gas turbine design that can be used for all the fuel blends (including 100% NH 3 ) without any changes to the system. The technological developments in the cooling system, gas turbine design, and materials that will be required for NH 3 combustion were identified and analyzed in this study to develop an advanced gas turbine design for NH 3 fuels. The study includes a combined cycle performance analysis with the NH 3 fuel blends using the advanced gas turbine design developed in this study. A techno-economic analysis was conducted for analyzing the impact of the NH 3 fuels on the levelized cost of electricity and cost sensitivities to fuel price and capacity factor.

20 FOSSIL-FUELED POWER PLANTS↗

Cooled Gas Turbine and Combined Cycle Analysis for H 2 -CH 4 Fuel Mixes (Up to 100% H 2 )

In this study, a cooled gas turbine analysis was conducted for varying levels of hydrogen (H 2 ) blends with the natural gas. The ultimate goal is to have a gas turbine design that can be used for all the fuel blends (including 100% H 2 ) without any changes to the system. The technological developments in the cooling system, gas turbine design and materials that will be required for H 2 combustion were identified and analyzed in this study to develop an advanced gas turbine design for H 2 fuels. The study includes a combined cycle performance analysis with the H 2 fuel blends using the advanced gas turbine design developed in this study. A techno-economic analysis was conducted for analyzing the impact of the H 2 fuels on the levelized cost of electricity and cost sensitivities to fuel price and capacity factor.

03 NATURAL GAS↗

NETL Gen-2 Oxygen Carrier Assessment

The National Energy Technology Laboratory’s (NETL) Research and Innovation Center (RIC) has been conducting laboratory-scale tests to develop a new chemical looping combustion (CLC) oxygen carrier (OC) having copper, iron, and alumina components. This OC, designated as the Gen-2 OC throughout this report, has high maximum oxygen capacity and has been tested extensively in the RIC methane-fueled chemical looping reforming. A screening analysis has been conducted to estimate the performance and cost of CLC when utilizing the Gen-2 OC. In this report, the performance and cost results are compared to those of a range of previously assessed CLC OCs to provide a basis to establish the relative merits and issues associated with the Gen-2 OC. Base load CLC power plants utilizing the Gen-2 OC and the three comparison OCs considered in this assessment (Fe 2 O 3- , CuO-, CaSO 4- based) are estimated to have thermal efficiency and cost of electricity (COE) characteristics potentially superior to those of the equivalent conventional pulverized coal (PC) power plant applying conventional, amine-based CO 2 capture technology. The current assessment does not address flexible plant operation. An evaluation of the CLC plant designed for flexible operation would need to include a comparable PC plant designed for flexible operation.

01 COAL, LIGNITE, AND PEAT↗

On-sky Performance of the CLASS Q -band Telescope

Here, the Cosmology Large Angular Scale Surveyor (CLASS) is mapping the polarization of the cosmic microwave background (CMB) at large angular scales (2 < ℓ ≲ 200) in search of a primordial gravitational wave B-mode signal down to a tensor-to-scalar ratio of r ≈ 0.01. The same data set will provide a near sample-variance-limited measurement of the optical depth to reionization. Between 2016 June and 2018 March, CLASS completed the largest ground-based Q-band CMB survey to date, covering over 31,000 square-degrees (75% of the sky), with an instantaneous array noise-equivalent temperature sensitivity of $32\,\mu {{\rm{K}}}_{\mathrm{cmb}}\sqrt{{\rm{s}}}$. Thus, we demonstrate that the detector optical loading (1.6 pW) and noise-equivalent power (19 $\mathrm{aW}\sqrt{{\rm{s}}}$) match the expected noise model dominated by photon bunching noise. We derive a 13.1 ± 0.3 K pW –1 calibration to antenna temperature based on Moon observations, which translates to an optical efficiency of 0.48 ± 0.02 and a 27 K system noise temperature. Finally, we report a Tau A flux density of 308 ± 11 Jy at 38.4 ± 0.2 GHz, consistent with the Wilkinson Microwave Anisotropy Probe Tau A time-dependent spectral flux density model.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-Level Switches for Advanced Time-Division Multiplexing

Superconducting quantum interference device (SQUID)-based time-division multiplexing (TDM) is a mature and widely implemented technology used to read out transition-edge sensor arrays. As the number of pixels in modern arrays continues to increase, a higher multiplexing factor is required to reduce the number of wires and amplifier channels. Yet, as the multiplexing factor is increased, the number of row-select wires (used to turn on a row of TDM SQUIDs in a two-dimensional configuration) also increases, limiting the reduction in array wires. We introduce a more advanced TDM architecture that enforces multi-level switching between subgroups of pixels. We show that this technique can dramatically reduce the number of required row-select lines. We also present the design, fabrication, and testing of a TDM multiplexer incorporating a two-level switch, which implements a second switch for each group of ten TDM pixels. In this application, a multiplexing factor of 100 can be addressed using ten group-select wiring pairs and ten row-select wiring pairs. We demonstrate multiplexer functionality and present measured operating margins of this new TDM multiplexer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗