Search NASASearch

Engineering topics

Stobie, J.

Publications and source records attributed to Stobie, J..

An Efficient Objective Analysis System for Parallel Computers

A new atmospheric objective analysis system designed for parallel computers will be described. The system can produce a global analysis (on a 1 X 1 lat-lon grid with 18 levels of heights and winds and 10 levels of moisture) using 120,000 observations in 17 minutes on 32 CPUs (SGI Origin 2000). No special parallel code is needed (e.g. MPI or multitasking) and the 32 CPUs do not have to be on the same platform. The system is totally portable and can run on several different architectures at once. In addition, the system can easily scale up to 100 or more CPUS. This will allow for much higher resolution and significant increases in input data. The system scales linearly as the number of observations and the number of grid points. The cost overhead in going from 1 to 32 CPUs is 18%. In addition, the analysis results are identical regardless of the number of processors used. This system has all the characteristics of optimal interpolation, combining detailed instrument and first guess error statistics to produce the best estimate of the atmospheric state. Static tests with a 2 X 2.5 resolution version of this system showed it's analysis increments are comparable to the latest NASA operational system including maintenance of mass-wind balance. Results from several months of cycling test in the Goddard EOS Data Assimilation System (GEOS DAS) show this new analysis retains the same level of agreement between the first guess and observations (O-F statistics) as the current operational system.

Stobie, J.

Low power, highly linear output buffer

A class AB CMOS output buffer has been designed for use on an IR focal plane array. Given the requirements for power dissipation and load capacitance a class A output, such as a source follower, would be unsuitable. The approach taken uses a class AB amplifier configured as a charge integrator. Thus it converts a charge packet in the focal plane multiplexer to a voltage which is then the output of the focal plane. With a quiescent current of 18 micro-a and a load capacitance of 100 pf, the amplifier has an open loop unity gain bandwidth of 900 khz. Integral nonlinearity is better than .03 percent over 5.5 volts when run with VDD-VSS = 6v.

Foley, D.

Short wavelength HgCdTe staring focal plane for low background astronomy applications

The design of a 128x128 staring short wave infrared (SWIR) HgCdTe focal plane incorporating charge integrating transimpedance input preamplifiers is presented. The preamplifiers improve device linearity and uniformity, and provide signal gain ahead of the miltiplexer and readout circuitry. Detector's with cutoff wavelength of 2.5 microns and operated at 80 K have demonstrated impedances in excess of 10(exp 16) ohms with 60 percent quantum efficiency. Focal plane performance using a smaller format device is presented which demonstrates the potential of this approach. Although the design is capable of achieving less than 30 rms electrons with todays technology, initial small format devices demonstrated a read noise of 100 rms electrons and were limited by the atypical high noise performance of the silicon process run. Luminescence from the active silicon circuitry in the multiplexer limits the minimum detector current to a few hundred electrons per second. Approaches to eliminate this excessive source of current is presented which should allow the focal plane to achieve detector background limited performance.

Hall, D.

1.0 to 2.5 micrometer short wavelength infrared /SWIR/ linear array technology for low background applications

A design concept is presented for a hybrid linear focal plane array operating in the 1.0 to 2.5 micron band under low background conditions such as encountered in spaceborne missions. The concept is based on direct gate coupling of the input from a photovoltaic mercury-cadmium telluride detector into a CCD multiplexer. Theoretical analysis indicates a specific detectivity at peak wavelength on the order of 10 to the 12th cm sq rt Hz/W when the system is operating at 200 K. Values of the voltage responsivity, specific detectivity and the relative voltage noise levels of the coupled system obtained in experimental studies with direct-gate-coupled 4.0-micron detectors support the theoretical analysis performed for the case of system detectivity limited by the CCD 1/f noise.

Stobie, J.