Search NASA⌕ Search

Engineering topics

Stockton, Amanda M.

Publications and source records attributed to Stockton, Amanda M..

Biomarker and Geochemical Assay Validation in Mars Analog Sites: Lessons from the FELDSPAR (Field Exploration and Life Detection Sampling for Planetary Analog Research) Project

Missions looking for signs of life on other worlds can often only take a few samples once they arrive. Making sense of these "few and far between" observations is easier if we know what a "normal" level of variation for that kind of planet is. Recent eruption sites in Iceland are good places to learn about this, because they have very little life present and the same types of rocks as many places on Mars. We have visited several of these sites in Iceland and tested many different kinds of measurements: the energy available for life, the amount of DNA (an important biological molecule) present, the relative amounts of different kinds of micro-organisms, and the specific minerals that make up the rocks and ground. In addition to recommendations for future expeditions, we have also shown that using early on-site measurements to choose later on-site sample sites is very helpful in reducing the number of sample sites needed.

Geochemical Assay Validation↗

A Recent Volcanic Eruption, Holuhraun, in the Central Highlands of Iceland as a Mars analog: The 2018 Field Campaign of FELDSPAR

In summer 2018, FELDSPAR conducted an analog sampling expedition to the Holuhraun volcanoin the central highlands of Iceland that erupted from August 2014 to February 2015. Holuhraun hassteep gradients within an otherwise relatively controlled region, and thus served as the primaryMars analog site for the 2018 FELDSPAR field campaign. Samples along gradients of mineralogyas measured via near-IR and visible reflectance spectroscopy, temperature as measured by an IRprobe, and physical location about the fissure (slope incline, directionality, height up the slope,etc.) were analyzed in-field with reflectance spectroscopy and X-ray fluorescence, in the field labfor adenosine trisphosphate (ATP) as an indicator of metabolic activity, and after return to thehome lab for both geochemical and geophysical parameters (moisture content, grain size, X-raydiffraction) and biochemical parameters (DNA content and speciation). This abstract representsthe first report on the 2018 field campaign with initial results and interpretation. This work is part ofField Exploration and Life Detection Sampling for Planetary Analogue Research (FELDSPAR), onFacebook @FELDSPAResearch.

Volcanic↗

Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip

There are no existing ultra-sterile lab-on-a-chip systems that can accept solid samples and perform complete chemical analyses without human intervention. The proposed solution is to demonstrate completely automated lab-on-a-chip manipulation of powdered solid samples, followed by on-chip liquid extraction and chemical analysis. This technology utilizes a newly invented glass micro-device for solid manipulation, which mates with existing lab-on-a-chip instrumentation. Devices are fabricated in a Class 10 cleanroom at the JPL MicroDevices Lab, and are plasma-cleaned before and after assembly. Solid samples enter the device through a drilled hole in the top. Existing micro-pumping technology is used to transfer milligrams of powdered sample into an extraction chamber where it is mixed with liquids to extract organic material. Subsequent chemical analysis is performed using portable microchip capillary electrophoresis systems (CE). These instruments have been used for ultra-highly sensitive (parts-per-trillion, pptr) analysis of organic compounds including amines, amino acids, aldehydes, ketones, carboxylic acids, and thiols. Fully autonomous amino acid analyses in liquids were demonstrated; however, to date there have been no reports of completely automated analysis of solid samples on chip. This approach utilizes an existing portable instrument that houses optics, high-voltage power supplies, and solenoids for fully autonomous microfluidic sample processing and CE analysis with laser-induced fluorescence (LIF) detection. Furthermore, the entire system can be sterilized and placed in a cleanroom environment for analyzing samples returned from extraterrestrial targets, if desired. This is an entirely new capability never demonstrated before. The ability to manipulate solid samples, coupled with lab-on-a-chip analysis technology, will enable ultraclean and ultrasensitive end-to-end analysis of samples that is orders of magnitude more sensitive than the ppb goal given in the Science Instruments.

Mora, Maria F.↗

Microchip Non-Aqueous Capillary Electrophoresis (MicronNACE) Method to Analyze Long-Chain Primary Amines

A protocol was developed as a first step in analyzing the complex organic aerosols present on Saturn's moon Titan, as well as the analogues of these aerosols (tholins) made on Earth. Labeling of primary amines using Pacific Blue succinimidyl ester is effected in ethanol with 25 mM triethylamine to maintain basic conditions. This reaction is allowed to equilibrate for at least one hour. Separation of the labeled primary amines is performed in ethanol with 1.05 M acetic acid, and 50 mM ammonium acetate in a commercial two-layer glass device with a standard crossmicrochannel measuring 50 microns wide by 20 microns deep. Injection potentials are optimized at 2 kV from the sample (negative) to the waste well (positive), with slight bias applied to the other two wells ( 0.4 and 0.8 V) to pinch the injection plug for the 30-s injection. Separation is performed at a potential of 5 kV along the channel, which has an effective separation distance of 7 cm. The use of ethanol in this method means that long-chain primary amines can be dissolved. Due to the low pH of the separation buffer, electro-osmotic flow (EOF) is minimized to allow for separation of both short-chain and longchain amines. As the freezing point of ethanol is much lower than water, this protocol can perform separations at temperatures lower than 0 C, which would not be possible in aqueous phase. This is of particular importance when considering in situ sampling of Titan aerosols, where unnecessary heating of the sample (even to room temperature) would lead to decomposition or unpredictable side reactions, which would make it difficult to characterize the sample appropriately.

Willis, Peter A.↗

Design and Operation of the Planetary In-Situ Capillary Electrophoresis System (PISCES)

The PISCES instrument is a portable, miniature, modular instrument designed to analyze organic molecular signatures of life. PISCES uses microcapillary electrophoresis (μCE) with laser-induced fluorescence detection (LIFD) to analyze fluorescently-labeled analytes prepared on a multi-layer microfluidic chip. As a modular instrument composed of five independently functioning units, each module can be easily detached from the system and used for subsystem testing in different environments, e.g. low temperature. The pneumatic module contains mechanical and electrical components necessary to control pneumatically-actuated valves for on-chip sample processing. A prototype LabVIEW program and two custom printed circuit boards (PCBs) operate the pneumatics module using an Arduino microcontroller, and a tentative design for the module’s housing has been developed. The high-voltage module contains circuitry required to apply varying electrical potentials to the electrophoretic channel of the microdevice. Work is currently being done to design the circuit and PCB for this module in collaboration with our SBIR partners at Los Gatos Research. The optical electronics module contains the spectrometer, laser, and laser power supply. The mounting components for the electronics and housing for the module have been designed, assembled, and tested. The optical module contains optical components to focus the laser to a 20μm spot in the center of the electrophoretic channel.The housing for this module has been designed and assembled with the aligned optical components inside.

Willis, Peter A.↗