Search NASA⌕ Search

Engineering topics

Stoica, Alexandru Dan

Publications and source records attributed to Stoica, Alexandru Dan.

At least 19 records

Synthesizing pseudo-Kossel lines from neutron transmission data. II. Validation with neutron diffraction data

A new method to recover the orientation matrix of a single crystal with a known unit cell by analyzing synthesized pseudo-Kossel lines from time-of-flight neutron transmission data has been outlined in a companion article [Dessieux et al. (2023). J. Appl. Cryst. 56, https://dx.doi.org/10.1107/S1600576723001346; referred to here as Article I]. In this work, validation of this new technique is presented by employing experimental neutron transmission and diffraction measurements performed on two copper single-crystal specimens. Time-of-flight spectra were recorded during rotation (ω) of the single crystals about a vertical axis perpendicular to the incident neutron beam. The λ–ω maps recorded in transmission are utilized to determine the crystal orientation with respect to the neutron beam, following the procedure presented in Article I. Further, to validate the indexing procedure, the crystal orientations are compared with those obtained via conventional methods using the diffraction data. The resulting pseudo-Kossel lines across the 2D detectors are also observed for the first time.

36 MATERIALS SCIENCE↗

Synthesizing pseudo-Kossel lines from neutron transmission data. I. An analytical approach for recovering single-crystal orientation

The energy-dispersive neutron spectra transmitted through single crystals are characterized by sharp Bragg dips at specific wavelengths, where Bragg's law is being fulfilled for certain crystallographic planes. This phenomenon allows for developing methods for crystal-orientation determination techniques similar to electron backscatter diffraction and X-ray diffraction microscopy. This work presents a new procedure to recover the orientation matrix for single crystals using transmission spectra recorded during rotation of a crystal about an axis perpendicular to a polychromatic neutron beam. The proposed method consists of an initial transformation of the as-collected wavelength–rotation maps to a wavevector $\textit{K}$ space, resulting in linear pseudo-Kossel lines that are suitable for analysis and indexing using image-processing procedures. Further, simulated neutron transmission spectra through a copper crystal with known orientations were used to set and prove the numerical approach. This technique may be expanded for cases where the neutron beam intersects multiple single-crystal grains with different orientations.

36 MATERIALS SCIENCE↗

A realistic guide misalignment model for the Second Target Station instruments at the Spallation Neutron Source

The Second Target Station (STS) at the Spallation Neutron Source, including a suite of initial instrument concepts, are being designed in Oak Ridge. The moderator size at STS is significantly smaller than that of the First Target Station, making the guide misalignment a more prominent concern. Here a realistic misalignment model based on Monte Carlo neutron ray tracing simulation was developed to evaluate the impacts of both the random misalignment and floor settlement on the performance of a toy model of 150 m straight guide system, and MENUS, an STS instrument concept with a typical guide design of two opposing Montel mirrors. The study shows that longer instruments, and instruments with complex curved mirrors/guides are sensitive to significant performance penalties due to misalignments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PIONEER, a high-resolution single-crystal polarized neutron diffractometer

PIONEER is a high Q-resolution, single-crystal, polarized neutron diffractometer at the Second Target Station (STS), Oak Ridge National Laboratory. It will provide the unprecedented capability of measuring tiny crystals (0.001 mm 3 , i.e., x-ray diffraction size), ultra-thin films (10 nm thickness), and weak structural and magnetic transitions. PIONEER benefits from the increased peak brightness of STS cold-neutron sources and uses advanced Montel mirrors that are able to deliver a focused beam with a high brilliance transfer, a homogeneous profile, and a low background. Monte Carlo simulations suggest that the optimized instrument has a high theoretical peak brilliance of 2.9 × 10 12 n cm -2 sr -1 Å -1 s -1 at 2.5 Å at the sample position, within a 5 × 5 mm 2 region and a ±0.3° divergence range. The moderator-to-sample distance is 60 m, providing a nominal wavelength band of 4.3 Å with a wavelength resolution better than 0.2% in the wavelength range of 1.0–6.0 Å. PIONEER is capable of characterizing large-scale periodic structures up to 200 Å. With a sample-to-detector distance of 0.8 m, PIONEER accommodates various sample environments, including low/high temperature, high pressure, and high magnetic/electric field. Additionally, a large cylindrical detector array (4.0 sr) with a radial collimator is planned to suppress the background scattering from sample environments. Bottom detector banks provide an additional 0.4 sr coverage or can be removed if needed to accommodate special sample environments. We present virtual experimental results to demonstrate the scientific performance of PIONEER in measuring tiny samples.

47 OTHER INSTRUMENTATION↗

VERDI: VERsatile DIffractometer with wide-angle polarization analysis for magnetic structure studies in powders and single crystals

The VERsatile DIffractometer will set a new standard for a world-class magnetic diffractometer with versatility for both powder and single crystal samples and capability for wide-angle polarization analysis. The instrument will utilize a large single-frame bandwidth and will offer high-resolution at low momentum transfers and excellent signal-to-noise ratio. A horizontal elliptical mirror concept with interchangeable guide pieces will provide high flexibility in beam divergence to allow for a high-resolution powder mode, a high-intensity single crystal mode, and a polarized beam option. A major science focus will be quantum materials that exhibit emergent properties arising from collective effects in condensed matter. The unique use of polarized neutrons to isolate the magnetic signature will provide optimal experimental input to state-of-the-art modeling approaches to access detailed insight into local magnetic ordering.

36 MATERIALS SCIENCE↗

MENUS—Materials engineering by neutron scattering

Materials engineering by neutron scattering (MENUS) at the second target station will be a transformational high-flux, versatile, multiscale materials engineering diffraction beamline with unprecedented new capabilities for the study of complex materials and structures. It will support both fundamental and applied materials research in a broad range of fields. MENUS will combine unprecedented long-wavelength neutron flux and unique detector coverage to enable real-time studies of complex structural and functional materials under external stimuli. The incorporated small angle neutron scattering and transmission/imaging capabilities will extend its sensitivity to larger length scales and higher spatial resolution. Multimodal MENUS will provide crystallographic and microstructure data to the materials science and engineering community to understand lattice strain/phase transition/microstructure/texture evolution in three orthogonal directions in complex material systems under combined extreme applied conditions. Finally, the capabilities of MENUS will open new scientific opportunities and meet the research needs for science challenges to enable studies of a range of phenomena and answer the key questions in material design/exploration, advanced material processing, transformative manufacturing, and material operations of national impacts in our daily life.

47 OTHER INSTRUMENTATION↗

In situ neutron diffraction study of fatigue behavior of CrFeCoNiMo 0.2 high entropy alloy

In situ neutron diffraction measurement was applied to study the low-cycle fatigue behavior of CrFeCoNiMo 0.2 high entropy alloy. A two-step stress-controlled fatigue test with a stress range of 100–460 and 20–500 MPa was employed. The as-cast sample was cycled 129,000 and 61,000 times, respectively, before fracture. The evolution of the lattice strain and peak intensity demonstrates that the main deformation mechanism is dislocation slip, while no evidence of stacking fault was found. A three-stage ratcheting was clearly observed. Under the stress-controlled mode, the experimentally determined dislocation density increases linearly with the ratcheting strain. Here, the increase of the dislocation density results in a decay of the ratcheting strain rate, which stabilizes the structure and is beneficial for fatigue resistance.

36 MATERIALS SCIENCE↗

How to design a focusing guide: The large moderator case1

As continuously shaped super-mirrors are becoming available, the conceptual design of focusing guides should explore a wider range of possibilities to accomplish an efficient neutron beam extraction. Starting from a desired phase-space volume at the sample position and using an upstream ray-tracing approach, the acceptance diagram of any focusing guide can be calculated at the moderator position. To ensure high brilliance transfer and homogeneous coverage, the acceptance diagram should be fully included in the neutron source emission phase-space volume. Following this idea, the guide system can be scaled into dimensionless geometric figures that convey performance limits for a desired cross-section reduction. Moreover, if we impose a monotonic increase of the reflection angle with divergence angle at the sample position, the shape of the mirror is analytically determined. This approach was applied in the design of a focusing guide for SNAP instrument at SNS, at ORNL, USA. The results of McStas simulations are presented with different options included. Our approach facilitates finding an optimal solution for connecting multiple guide pieces to avoid excessive losses and ensure a homogeneous phase space coverage.

Frost, Matthew↗

Determination of Stress-Free Lattice Spacing (D₀) for Residual Stress Relaxation Measurement in Ni-based Superalloys by Neutron Diffraction

The residual stress and its relaxation in critical engineering components are key to structural materials reliability. The determination of residual stress in bulk engineering structures like Ni-based superalloys can be conducted by measuring the lattice strain with penetrating neutron diffraction. The state-of-the-art engineering diffraction beamline VULCAN at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) provides the critical capability to evaluate the residual strain/stress relaxation in engineering component thanks to the high flux and event data features. By the means of residual stress/strain calculation, it is critical to accurately determine the stress-free lattice spacing d₀, which can be altered by the change of chemistry, unrelieved stress, and measurement scheme. Here we reported d₀ determination for determining residual stress relaxation and distribution in Alloy 718 superalloys after different quenching treatments. Selection of locations for d₀ measurement was discussed by considering the neutron path, attenuation and sample alignment. A dynamic d₀ that resulted from atom diffusion and chemistry change was estimated as function of time for the in-situ relaxation characterization. It demonstrated how the dynamic d₀ values may influence on the strain calculation in different thermally treated samples. The results highlight the importance of dynamic d₀ for in-situ relaxation involving chemical changes and provide guidance to the dynamic d₀ measurement and simulation.

36 MATERIALS SCIENCE↗

First Experiments: New Science Opportunities at the Spallation Neutron Source Second Target Station (abridged)

This brochure is an abridged version of a more comprehensive companion report. DOE proposes to build a Second Target Station (STS) at SNS to produce beams of cold neutrons with world-leading peak brightness at a repetition rate of 15 Hz, providing broad energy/wavelength ranges that can be used simultaneously. Construction of the STS will provide transformative capabilities that allow thousands of users from national laboratories, universities, and industry to address grand scientific challenges [Hemminger 2015], advance energy research, and accelerate industrial innovations through the combination of cold (long-wavelength) neutrons of unprecedented peak brightness and short neutron pulses with broad ranges of usable wavelengths or energy. The STS Project, now in progress at ORNL, will design, construct, install, and commission the facilities and equipment needed to create a world-leading source of cold neutrons of unprecedented peak brightness at SNS. Key aspects of the STS design, including preliminary descriptions of an illustrative suite of eight instruments, are presented in the section “The STS at SNS.” The capabilities offered by the STS instruments (22 when fully built out) will complement those of the FTS and HFIR, providing the United States with unparalleled resources for neutron scattering at the world’s leading high–peak brightness cold neutron source.

43 PARTICLE ACCELERATORS↗

First Experiments: New Science Opportunities at the Spallation Neutron Source Second Target Station

Leadership in materials science underpins future technologies in energy, security, and other applications that drive this nation’s economy. Neutron scattering is among the crucial characterization techniques necessary to ensure a world-leading position in materials science for the United States. The Second Target Station (STS) at the Spallation Neutron Source (SNS) will provide transformative new capabilities for the study of a broad range of materials using neutron scattering and will support users in many fields of research—materials science, physics, chemistry, geology, biology, and engineering, among others—and from academia, government laboratories, and industry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

VULCAN: A “hammer” for high-temperature materials research

Understanding changes in chemistry, microstructure, and physical properties during synthesis, processing, testing, and even service is vital for materials design and performance. Compared to traditional postmortem material characterization tools, in situ crystallographic characterization can provide considerable data and information on evolution of chemistry, dislocations, twinning, texture, and strains when a material is under external stimuli. Neutrons especially are able to probe material bulk properties and behaviors in extreme environments, thanks to their deep penetrating power and unique sensitivity to differentiate elements from lightweight to transition-metal atoms. In this article, we introduce and describe a diffractometer named VULCAN, which is located at Oak Ridge National Laboratory. Finally, this represents a powerful tool to understand materials properties and behaviors under complex environments, in particular, at high temperatures.

36 MATERIALS SCIENCE↗

A first-principles approach to the optimization of neutron-focusing guide design and development

Fundamental optical concepts are utilized across all fields of scientific instrumentation. In the case of beam-like systems in neutron scattering instrumentation (low-divergence trajectories taken over long distances), quantities describing a system can be scaled into dimensionless figures of merit that convey performance characteristics and geometric limits. Furthermore, this first-principles approach facilitates a straight forward means by which to tailor an optical system to a defined source-sample configuration, as well as further inform guide surface shapes and reflectivity requirements. These principles will be presented and applied incorporated to examples showing their relevance to practical applications and future instrumentation.

Frost, Matthew J.↗

PIND: High spatial resolution by pinhole neutron diffraction

Here, a pinhole neutron diffraction (PIND) technique was developed to enable improving the spatial resolution down to 250 μm. Instead of the conventional engineering diffraction method which integrates all the diffraction signals on the detector plane, the PIND setup utilizes the diffraction pattern of each pixel on 2D detectors. The proposed PIND arrangement enables improving the spatial resolution of time-of-flight instruments and allows solving problems involving steep gradients of strain or texture. The phase content and preferential orientation of grains inside samples can be spatially resolved in 2D/3D. Further, PIND retains the capability of in-situ non-destructive neutron diffraction mapping of lattice strain and grain orientation under external stimuli such as temperature and force.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Applying neutron transmission physics and 3D statistical full-field model to understand 2D Bragg-edge imaging

Bragg-edge imaging, which is also known as neutron radiography, has recently emerged as a novel crystalline characterization technique. Modelling of this novel technique by incorporating various features of the underlying microstructure (including the crystallographic texture, the morphological texture, and the grain size) of the material remains a subject of considerable research and development. In this paper, Inconel 718 samples made by additive manufacturing were investigated by neutron diffraction and neutron radiography techniques. The specimen features strong morphological and crystallographic textures and a highly heterogeneous microstructure. A 3D statistical full-field model is introduced by taking details of the microstructure into account to understand the experimental neutron radiography results. The Bragg-edge imaging and the total cross section were calculated based on the neutron transmission physics. A good match was obtained between the model predictions and experimental results at different incident beam angles with respect to the sample build direction. The current theoretical approach has the ability to incorporate 3D spatially resolved microstructural heterogeneity information and shows promise in understanding the 2D neutron radiography of bulk samples. With further development to incorporate the heterogeneity in lattice strain in the model, it can be used as a powerful tool in the future to better understand the neutron radiography data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single crystal to polycrystal neutron transmission simulation

A collection of routines for calculation of the total cross section that determines the attenuation of neutrons by crystalline solids is presented. The total cross section is calculated semi-empirically as a function of crystal structure, neutron energy, temperature, and crystal orientation. The semi-empirical formula includes the contribution of parasitic Bragg scattering to the total cross section using both the crystal’s mosaic spread value and its orientation with respect to the neutron beam direction as parameters. These routines allow users to enter a distribution of crystal orientations for calculation of total cross sections of user defined powder or pseudo powder distributions, which enables simulation of non-uniformities such as texture and strain. In conclusion, the spectra for neutron transmission simulations in the neutron thermal energy range (2 meV–100 meV) are presented for single crystal and polycrystal samples and compared to measurements.

36 MATERIALS SCIENCE↗

Characterization of Crystallographic Structures Using Bragg-Edge Neutron Imaging at the Spallation Neutron Source

Over the past decade, wavelength-dependent neutron radiography, also known as Bragg-edge imaging, has been employed as a non-destructive bulk characterization method due to its sensitivity to coherent elastic neutron scattering that is associated with crystalline structures. Several analysis approaches have been developed to quantitatively determine crystalline orientation, lattice strain, and phase distribution. In this study, we report a systematic investigation of the crystal structures of metallic materials (such as selected textureless powder samples and additively manufactured (AM) Inconel 718 samples), using Bragg-edge imaging at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS). Firstly, we have implemented a phenomenological Gaussian-based fitting in a Python-based computer called iBeatles. Secondly, we have developed a model-based approach to analyze Bragg-edge transmission spectra, which allows quantitative determination of the crystallographic attributes. Moreover, neutron diffraction measurements were carried out to validate the Bragg-edge analytical methods. These results demonstrate that the microstructural complexity (in this case, texture) plays a key role in determining the crystallographic parameters (lattice constant or interplanar spacing), which implies that the Bragg-edge image analysis methods must be carefully selected based on the material structures.

47 OTHER INSTRUMENTATION↗

In-situ Neutron Diffraction Analysis of Crystal Plasticity of Retained Austenite in Bearing Steel

The presence of retained austenite in bearing steels can have a significant effect on the mechanical response of the material at varying length scales. Since retained austenite is metastable and cannot be produced independently without martensite/carbides, the key physical data on elastic-plastic behaviour is absent. In order to address this issue, this study investigates the transformation behaviour of retained austenite using in-situ neutron diffraction during uniaxial tensile testing of through hardened A485 (Grade 1) bearing steel. The study showed that retained austenite does not transform until the yield point of 1.0 GPa, and the transformation suddenly initiates once the true stress exceeds the macroscopic yield point. Analysis of the lattice strain and evolution of peak intensities showed that most of the deformation is accommodated by the retained austenite with <200> crystallographic direction parallel to the loading direction (LD). Analysis further revealed that these austenite planes were transformed into martensite with <211> direction parallel with the LD.

Bedekar, Vikram↗