Magnetically suspended Stirling cryogenic space refrigerator Test results

In 1979, a project leading to the development of a Stirling type cryogenic refrigerator for spaceborne application was initiated. The refrigerator is to generate five watts of net cooling at a temperature of 65 K. An operation without maintenance for a period of five years is required. A novel approach was selected for meeting the life requirement, taking into account an electromagnetic suspension of the moving parts. The fabrication of the hardware has now been completed and the performance of the refrigerator has been measured. The present paper provides a short review of the Stirling cycle, a description of the refrigerator design, and a summary of the test results. The new refrigerator configuration contains four major features, including a purely rectilinear drive, magnetic bearings, clearance seals, and all metal/ceramic working space surfaces. The displacer and the piston are supported and guided by magnetic bearings. The magnetic bearing consists of a set of electromagnetic actuators and radial position transducers.

Daniels, A.↗

A magnetically suspended linearly driven cryogenic refrigerator

This paper described a novel Stirling cycle cryogenic refrigerator which was designed, fabricated and successfully tested at Philips Laboratories. The prominent features of the machine are an electro-magnetic bearing system, a pair of moving magnet linear motors, and clearance seals with a 25 mu m radial gap. The all-metal and ceramic construction eliminates long-term organic contamination of the helium working fluid. The axial positions of the piston and displacer are electronically controlled, permitting independent adjustment of the amplitude of each and their relative phase relationship during operation. A simple passive counterbalance reduces axial vibrations. The design of the refrigerator system components is discussed and a comparison is made between performance estimates and measured results.

Stolfi, F.↗