Search NASA⌕ Search

Engineering topics

Stone, Daniel K.

Publications and source records attributed to Stone, Daniel K..

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

International Intercomparison for Nuclear Accident Dosimetry Using Godiva-IV

During the week of August 22, 2022, Integral Experiment Request (IER) 538, an international blind intercomparison for nuclear accident dosimetry (NAD) exercise, was completed using the Godiva-IV critical assembly at the National Criticality Experiments Research Center (NCERC) located in the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). This exercise builds upon a series of experiments that include the characterization the radiation fields around Godiva (IER-147) and Flattop (IER-252) and follow up intercomparisons of dosimetry around both Godiva IV and Flattop (IER-148 and IER-253, respectively). The participants consisted of seven Department of Energy laboratories and one laboratory each from the US Navy, United Kingdom, and France. The participants of the exercise were Lawrence Livermore National Laboratory (LLNL); Los Alamos National Laboratory (LANL); Sandia National Laboratory (SNL); Savannah River Site (SRS); Hanford Site, Missions Support and Test Services (MSTS); Y-12 National Security Complex (Y-12); Naval Dosimetry Center (NDC); Atomic Weapons Establishment (AWE); and Institut de Radioprotection et de Sûreté Nucléaire (IRSN). MSTS dosimeters were included in the irradiations but not reported for evaluation. This report primarily discusses the performance of the 24 hour results submitted by participants, though available final results are briefly discussed. Information for each irradiation performed is provided for participating laboratories to produce their own final report which will be incorporated into the CED-4a report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗