Search NASA⌕ Search

Engineering topics

Stoner, Jon

Publications and source records attributed to Stoner, Jon.

Completion and Testing of a New High-Temperature Cell Holder to Support High Dose Rate Electron Beam Irradiations of Select Sulfur Chlorides (S2Cl2 and SOCl2) for Advanced Low Temperature Chlorination of Zirconium-based Used Nuclear Fuel Cladding

Short communication on the completion and testing of a new high-temperature cell holder to support high dose rate electron beam irradiations of select sulfur chlorides (S2Cl2 and SOCl2) for advanced low temperature chlorination of zirconium-based used nuclear fuel cladding.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High purity 47 Sc production using high-energy photons and natural vanadium targets

We report Scandium-47 ( 47 Sc) is of high value for targeted radiotherapy and theranostics; we report a novel, cost-effective approach to produce extremely high-purity 47 Sc via photonuclear irradiation of natural vanadium. Irradiations at bremsstrahlung end-point energies below 26 and at 38 MeV produce > 99.99% and 98.8 ± 3.1% pure 47 Sc (respectively). Linear scaling of experimental data suggests producing 100+ mCi quantities of 47 Sc may be feasible via this approach. Future research into refinement and scale-up to support pre-clinical and clinical research with this production pathway is recommended.

07 ISOTOPE AND RADIATION SOURCES↗

Multi-plate interceptive electron beam energy diagnostic—Implementation and validation

A previous publication [P. D. McChesney, “Multi-plate interceptive electron beam energy diagnostic—Theoretical design,” AIP Adv. (submitted)] reported a new interceptive electron beam kinetic energy measurement technique based on the beam penetration depth within a stack of conductive plates and gave results on the theoretical design of such a device. This paper expands on this and gives further results on the actual implementation of the diagnostic. The device geometry and measurement electronics system are described in detail. A prototype version of the multi-plate diagnostic was fabricated and tested using an electron linear accelerator at the Idaho Accelerator Center (IAC). A high-precision magnetic spectrometer system was designed and built for the purpose of validating the multi-plate diagnostic’s energy measurement capabilities. It was found that the diagnostic provides electron beam energy estimates that are accurate to better than the 10% level.

43 PARTICLE ACCELERATORS↗

Optimization of commercial scale photonuclear production of radioisotopes

Photonuclear production of radioisotopes driven by bremsstrahlung photons using a linear electron accelerator in the suitable energy range is a promising method for producing radioisotopes. The photonuclear production method is capable of making radioisotopes more conveniently, cheaply and with much less radioactive waste compared to existing methods. Historically, photo-nuclear reactions have not been exploited for isotope production because of the low specific activity that is generally associated with this production process, although the technique is well-known to be capable of producing large quantities of certain radioisotopes. We describe an optimization technique for a set of parameters to maximize specific activity of the final product. This set includes the electron beam energy and current, the end station design (an integrated converter and target as well as cooling system), the purity of materials used, and the activation time. These parameters are mutually dependent and thus their optimization is not trivial. {sup 67}Cu photonuclear production via {sup 68}Zn({gamma}p){sup 67}Cu reaction was used as an example of such an optimization process.

07 ISOTOPE AND RADIATION SOURCES↗