Search NASA⌕ Search

Engineering topics

Stoupin, Stanislav

Publications and source records attributed to Stoupin, Stanislav.

Performance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility

Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >10 13 14 MeV DT neutrons or >10 9 n cm -2 ns -1 . Here, we describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.

47 OTHER INSTRUMENTATION↗

High-efficiency transmission-mode diamond scintillator for quantitative characterization of X-ray beams

The luminance of a transmission mode X-ray scintillator diamond plate is dominated by induced defect centers having an excited state lifetime less than 10 msec, and in embodiments less than 1 msec, 100 usec, 10 used, 1 used, 100 nsec, or even 50 nsec, thereby providing enhanced X-ray luminance response and an X-ray flux dynamic range that is linear with X-ray flux on a log-log scale over at least three orders of magnitude. The diamond plate can be a single crystal having a dislocation density of less than 104 per square centimeter, and having surfaces that are ion milled instead of mechanically polished. The defect centers can be SiV centers induced by silicon doping during CVD diamond formation, and/or NV0 centers formed by nitrogen doping followed by applying electron beam irradiation of the diamond plate and annealing.

Antipov, Sergey↗

Charge density wave with anomalous temperature dependence in UPt 2 Si 2

Using single-crystal neutron and x-ray diffraction, we discovered a charge density wave (CDW) below 320 K, which accounts for the long-sought origin of the heat capacity and resistivity anomalies in UPt 2 Si 2 . The modulation wave vector, Q mod , is intriguingly similar to the incommensurate wave vector of URu 2 Si 2 . Q mod shows an unusual temperature dependence, shifting from commensurate to incommensurate position upon cooling and becoming locked at aproximately (0.42 0 0) near 180 K. Furthermore, bulk measurements indicate a crossover toward a correlated coherent state around the same temperature, suggesting an interplay between the CDW and Kondo-lattice-like coherence before coexisting antiferromagnetic order sets in at T N =35 Κ.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond

Enhancement of X-ray excited optical luminescence in a 100 µm-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing is demonstrated. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range 7.6 × 10 8 to 1.26 × 10 12 photons s -1 mm -2 for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.

Instruments & Instrumentation↗