Search NASA⌕ Search

Engineering topics

Stracener, Daniel W

Publications and source records attributed to Stracener, Daniel W.

At least 19 records

Large scale accelerator production of 225Ac: Effective cross sections for 78–192 MeV protons incident on 232Th targets

Actinium-225 and 213 Bi have been used successfully in targeted alpha therapy (TAT) in preclinical and clinical research. This paper is a continuation of research activities aiming to expand the availability of 225 Ac. The high energy proton spallation reaction on natural thorium metal target has been utilized to produce millicurie quantities of 225 Ac. The results of sixteen irradiation experiments of Th metal at beam energies between 78 and 200 MeV are summarized in this work. Irradiations have been conducted at Brookhaven National Laboratory (BNL) and Los Alamos National Laboratory (LANL), while target dissolution and processing was carried out at Oak Ridge National Laboratory (ORNL). Excitation functions for actinium and thorium isotopes as well as for some of the fission products are presented. The cross sections for production of 225 Ac range from 3.6 to 16.7 mb in the incident proton energy range of 78 to 192 MeV. Based on these data, production of Curie quantities of 225Ac is possible by irradiating a 5.0 g cm -2232 Th target for 10 days in either BNL or LANL proton irradiation facilities.

139Ce↗

Ion Source Development for Ultratrace Detection of Uranium and Thorium

A hot-cavity surface ionization source and a hot-cavity laser ion source are evaluated in terms of ionization efficiencies for generating ion beams of U and Th. The work is motivated by the need for more efficient ion sources for detecting ultratrace U and Th impurities in a copper matrix by mass spectrometry techniques such as accelerator mass spectrometry (AMS). The performances of the ion sources are characterized using uranyl nitrate and thorium nitrate sample materials and sample sizes of 20 - 40 g of U or Th. For the surface source, the dominant ion beams observed are UO+ or ThO+ and ionization efficiencies of 2-4% have been obtained with W and Re cavities. Three-step resonant photoionization of U atoms is studied and an ionization efficiency of 8.7% has been obtained with the laser ion source. The positive ion sources promise more than an order of magnitude more efficient than conventional Cs-sputter negative ion sources used for AMS. In addition, the laser ion source is highly selective and effective in suppressing interfering and ions. Work is in progress to improve the efficiencies of both positive ion sources.

Liu, Yuan↗

On the 57-us isomer in 93Rb

The 253.3 keV isomeric state located in 93Rb was studied at the HRIBF in Oak Ridge. The state in question was populated in the decay of 93Kr produced by proton induced fission of 238U and separated using the isotope separation on line technique. We report that the 253.3 keV level does not reveal isomerism and the upper limit of the half life from our measurement is 4 ns. Our findings are supported by previously reported results that were not taken into account in the latest nuclear databases.

Miernik, Krzysztof A↗

On-Line Commissioning of the HRIBF Resonant Ionization Laser Ion Source

A highly-selective resonant ionization laser ion source has been successfully commissioned at the Holifield Radioactive Ion Beam Facility, Oak Ridge National Laboratory, for the production of pure beams of short-lived nuclei for spectroscopic studies. The laser ion source provided beams of neutron-rich Ga isotopes to the Low-energy Radioactive Ion Beam Spectroscopy Station for beta decay measurements. The radioactive Ga isotopes were produced by 50-MeV proton induced fission of 238U and ionized by laser radiation using a two-step resonant ionization scheme. Isobarically pure 83Ga, 85Ga, and 86Ga beams were delivered to the experiment at approximate rates of 12000 ions/s, 100 ions/s, and 3 ions/s, respectively.

Liu, Yuan↗

Electromagnetic properties of the 2+ state in 134Te: Influence of core excitation on single-particle orbits beyond 132Sn

The g factor and B (E2) of the first excited 2+ state have been measured following Coulomb excitation ofthe neutron-rich semimagic nuclide 134Te (two protons outside 132Sn) produced as a radioactive beam. The precision achieved matches related g-factor measurements on stable beams and distinguishes between alternative models. The B(E2) measurement exposes quadrupole strength in the 2+ state beyond that predicted by current large-basis shell-model calculations. This additional quadrupole strength can be attributed to coupling between the two valence protons and excitations of the 132Sn core. However, the wave functions of the low-excitation positive-parity states in 134Te up to 6+ remain dominated by the (g7/2)2 configuration.

Stuchbery, Andrew E↗

Wear Measurement of Highly Cross-linked UHMWPE using a 7 Be Tracer Implantation Technique

The very low wear rates achieved with the current highly cross-linked ultrahigh molecular weight polyethylenes (UHMWPE) used in joint prostheses have proven to be difficult to measure accurately by gravimetry. Tracer methods are there- fore being explored. The purpose of this study was to perform a proof-of-concept experiment on the use of the radioactive tracer beryllium-7 (7Be) for the determination of in vitro wear in a highly cross-linked orthopedic UHMWPE. Three cross-linked and four conventional UHMWPE pins made from compression- molded GUR 1050, were activated with 109 to 1010 7Be nuclei using a new implantation setup that produced a homogenous distribution of implanted nuclei up to 8.5 lm below the surface. The pins were tested for wear in a six-station pin-on-flat appara- tus for up to 7.1 million cycles (178 km). A Germanium gamma detector was employed to determine activity loss of the UHMWPE pins at preset intervals during the wear test. The wear of the cross-linked UHMWPE pins was readily detected and esti- mated to be 17 6 3 lg per million cycles. The conventional-to- cross-linked ratio of the wear rates was 13.1 6 0.8, in the expected range for these materials. Oxidative degradation dam- age from implantation was negligible; however, a weak depend- ence of wear on implantation dose was observed limiting the number of radioactive tracer atoms that can be introduced. Future applications of this tracer technology may include the analysis of location-specific wear, such as loss of material in the post or backside of a tibial insert.

cross-linked↗

Time Profiles of Ions Produced in a Hot-Cavity Resonant Ionization Laser Ion Source

The time profiles of Cu, Sn and Ni ions extracted from a hot-cavity resonant ionization laser ion source are investigated. The ions are produced in the ion source by three-photon resonant ionization with pulsed Ti:Sapphire lasers. Measurements show that the time spread of these ions generated within laser pulses of about 30 ns could be larger than 100 s when the ions are extracted from the ion source. A one-dimensional ion-transport model using the Monte Carlo method is developed to simulate the time dependence of the ion pulses. The observed ion temporal profiles agree reasonably well with the predictions of the model, which indicates that a substantial fraction of the extracted ions are generated in the vapor-transfer tube rather than the hot cavity and that ion-wall collisions are suppressed inside the ion source by an undetermined ion confinement mechanism. Three-dimensional modeling will be necessary to understand the strong reduction in losses expected from ion-wall collisions which we interpret as evidence for confinement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ISOL science at the Holifield Radioactive Ion Beam Facility

The Holi eld Radioactive Ion Beam Facility, located in Oak Ridge, Tennessee, is operated as a National User Facility for the U.S. Department of Energy, producing high quality ISOL beams of short-lived, radioactive nuclei for studies of exotic nuclei, astrophysics research, and various societal applications. The primary driver, the Oak Ridge Isochronous Cyclotron, produces rare isotopes by bombarding highly refractory targets with light ions. The radioactive isotopes are ionized, formed into a beam, mass selected, injected into the 25-MV Tandem, accelerated, and used in experiments. This article reviews HRIBF and its science.

43 PARTICLE ACCELERATORS↗

Radioactive Ion Beam Production Capabilities at the Holifield Radioactive Ion Beam Facility

The Holifield Radioactive Ion Beam Facility (HRIBF) is a national user facility for research with radioactive ion beams (RIBs) that has been in routine operation since 1996. It is located at Oak Ridge National Laboratory (ORNL) and operated by the ORNL Physics Division. The principal mission of HRIBF is the production of high-quality beams of short-lived radioactive isotopes to support research in nuclear structure physics and nuclear astrophysics. HRIBF is currently unique worldwide in its ability to provide neutron-rich fission fragment beams post-accelerated to energies above the Coulomb barrier for nuclear reactions.

43 PARTICLE ACCELERATORS↗

EBIS/T charge breeding for intense rare isotope beams at MSU

Experiments with reaccelerated beams are an essential component of the science program of existing and future rare isotope beam facilities. NSCL is currently constructing ReA3, a reaccelerator for rare isotopes that have been produced by projectile fragmentation and in-flight fission and that have been thermalized in a gas stopper. The resulting low-energy beam will be brought to an Electron Beam Ion Source/Trap (EBIS/T) in order to obtain highly charged ions at an energy of 12 keV/u. This charge breeder is followed by a compact linear accelerator with a maximum beam energy of 3MeV/u for U-238 and higher energies for lighter isotopes. Next-generation rare isotope beam facilities like the Facility for Rare Isotope Beams FRIB, but also existing Isotope Separator On-line (ISOL) facilities are expected to provide rare-isotope beam rates in the order of 10(11) particles per second for reacceleration. At present the most promising scheme to efficiently start the reacceleration of these intense beams is the use of a next-generation high-current charge-breeder based on an EBIS/T. MSU has formed a collaboration to develop an EBIT for this purpose. A new high-current EBIS/T breeder will be developed and constructed at MSU, where also first tests on achievable beam rate capability will be performed. The EBIT is planned to be installed at the Isotope Separator and Accelerator facility ISAC at TRIUMF laboratory for on-line tests with rare isotope beams and to provide intense energetic reaccelerated radioactive beams. The status of the ReA3-EBIS/T in the NSCL reaccelerator project is given with a brief summary of results, followed by a discussion of plans for the future high-intensity EBIS/T charge breeder.

43 PARTICLE ACCELERATORS↗

Dynamical polarization in the Coulomb breakup on loosely bound {sup 17}F.

Angular distributions of the Coulomb breakup of radioactive {sup 17}F were measured by impinging a 10 MeV/nucleon beam on {sup 208}Pb and on {sup 58}Ni to study the dynamic polarization effects. The breakup products, oxygen and a proton, were detected in coincidence. First-order perturbation theory significantly overpredicts the breakup cross section for the {sup 208}Pb target. Dynamical calculations with a dynamic polarization as the leading order correction were performed. The calculations reproduce the data for {sup 17}F on {sup 58}Ni but overpredict the breakup of {sup 17}F on {sup 208}Pb by a factor of two at forward angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emittance characterization of a hot-cavity laser ion source at Holifield Radioactive Ion Beam Facility

The first investigation of the transverse emittance of a hot-cavity laser ion source based on all-solid-state Ti:sapphire lasers is presented. The emittances of {sup 63}Cu ion beams generated by three-photon resonant ionization are measured and compared with that of the {sup 69}Ga and {sup 39}K ion beams resulting from surface ionization in the same ion source. A self-consistent unbiased elliptical exclusion method is adapted for noise reduction and emittance analysis. Typical values of the rms and 90% fractional emittances of the Cu ion beams at 20 keV energy are found to be about 2 and 8 {pi} mm mrad, respectively, for the ion currents of 2-40 nA investigated. The emittances of the laser-produced Cu ion beams are smaller than those of the surface-ionized Ga and K ion beams.

43 PARTICLE ACCELERATORS↗