Resuspension of Particles by Aerodynamic Deagglomeration

A deagglomerator system was developed, characterized by laboratory tests and flown under low gravity (low-g) microgravity conditions. Requirements for a dry powder deagglomeration system were generated by university and National Aeronautics and Space Administration (NASA) scientists from diverse fields of interest including exobiology, planetary sciences, and atmospheric sciences. Existing deagglomeration methods and devices are reviewed. An aerosol generation method suitable for dry powders over a large range of particles sizes and types at high concentrations with consistent deagglomeration efficiency was evaluated. Development of a pulsed-flow laboratory device and experimental approaches to meet the requirements without being g- dependent are described. Results of laboratory one-g quantitative characterization on one type of dry powder particle generator is discussed. Data from NASA low-g tests are summarized.

Fonda, Mark↗

A New Optical Aerosol Spectrometer

An optical particle spectrometer capable of measuring aerosol particle size distributions from 0.02 to 100 micrometers has been developed. This instrument combines several optical methods in one, in-situ configuration; it can provide continuous data collection to encompass the wide dynamic size ranges and concentrations found in studies of modeled planetary atmospheres as well as terrestrial air quality research. Currently, the system is incorporated into an eight liter capacity spherical pressure vessel that is appropriate both for flowthrough and for in-situ particle generation. The optical sizing methods include polarization ratio, The scattering, and forward scattering detectors, with illumination from a fiber-coupled, Argon-ion laser. As particle sizes increase above 0.1 micrometer, a customized electronics and software system automatically shifts from polarization to diffraction-based measurements as the angular scattering detectors attain acceptable signal-to-noise ratios. The number concentration detection limits are estimated to be in the part-per-trillion (ppT by volume) range, or roughly 1000 submicron particles per cubic centimeter. Results from static experiments using HFC134A (approved light scattering gas standard), flow-through experiments using sodium chloride (NaCl) and carbon particles, and dynamic 'Tholin' (photochemical produced particles from ultraviolet (UV)-irradiated acetylene and nitrogen) experiments have been obtained. The optical spectrometer data obtained with particles have compared well with particle sizes determined by electron microscopy. The 'Tholin' tests provided real-time size and concentration data as the particles grew from about 30 nanometers to about 0.8 micrometers, with concentrations ranging from ppT to ppB, by volume. Tests are still underway, to better define sizing accuracy and concentration limits, these results will be reported.

Fonda, Mark↗