Search NASA⌕ Search

Engineering topics

Straub, Tim M.

Publications and source records attributed to Straub, Tim M..

Computational Fluid Dynamics Modeling of Bacillus anthracis Spore Deposition in Rabbit and Human Respiratory Airways

Three-dimensional computational fluid dynamics and Lagrangian particle deposition models were developed to compare the deposition of aerosolized Bacillus anthracis spores in the respiratory airways of a human with that of the rabbit, a species commonly used in the study of anthrax disease. The respiratory airway geometries for each species were derived from computed tomography (CT) or µCT images. Both models encompassed airways that extended from the external nose to the lung with a total of 272 outlets in the human model and 2878 outlets in the rabbit model. All simulations of spore deposition were conducted under transient, inhalation-exhalation breathing conditions using average species-specific minute volumes. The highest exposure concentration was modeled in the rabbit based upon prior acute inhalation studies. For comparison, human simulation was also conducted at the same concentration. Results demonstrated that regional spore deposition patterns were sensitive to airway geometry and ventilation profiles. Due to the complex airway geometries in the rabbit nose, higher spore deposition efficiency was predicted in the upper conducting airways compared to the human at the same air concentration of anthrax spores. As a result, higher particle deposition was predicted in the conducting airways and deep lung of the human compared to the rabbit lung due to differences in airway branching pattern. This information can be used to refine published and ongoing biokinetic models of inhalation anthrax spore exposures, which currently estimate deposited spore concentrations based solely upon exposure concentrations and inhaled doses that do not factor in species-specific anatomy and physiology.

bacillus anthracis↗

Field application of pathogen detection technologies

Over the last 10 years there has been a significant increase in commercial products designed for field-based detection of microbial pathogens. This is due, in part, to the anthrax attacks in the United States in 2001, and the need for first responders to quickly identify the composition of suspected white powders and other potential biothreats. Demand for rapid detection is also driven by the need to ensure safe food, water, and environmental systems. From a technology perspective, rapid identification methods have largely capitalized on PCR and other molecular recognition techniques that can be deployed as robust field instrumentation. Examples of the relevant needs include the ability to: 1) declare a water distribution system free of microbial pathogens after a pipe/main break repair; 2) assess risks of contamination such as when produce production and processing plants are located near concentrated animal feeing operations; 3) evaluate the safety of ready-to-eat products; 4) determine the extent of potential serious disease outbreaks in remote and/or disaster stricken areas where access to clinical laboratories is not an immediate option; and 5) quickly assess credible biological terrorism events. Many of the principles underlying rapid detection methods are derived from methods for environmental microbiology, but there is a dearth of literature describing and evaluating field-based detection systems. Thus, the aims of this chapter are to: 1) summarize the different kinds of commercially available sampling kits and field-based biological detectors; 2) highlight some of the continued challenges of sample preparation to stimulate new research towards minimizing the impact of inhibitors on PCR-based detection systems; 3) describe our general rationale and statistically-based approach for instrument evaluation; 4) provide statistical and spatial guidelines for developing valid sampling plans; and 5) summarize some current needs and emerging technologies. This information is presented both to highlight the state of the field, and to also highlight major questions that students may wish to consider investigating further. Where possible we will cite studies that have been conducted and published either in traditional peer-reviewed or other literature (e.g., AOAC International Methods).

Straub, Tim M.↗

Bacillus anthracis spores germinate extracellularly at air-liquid interface in an in vitro lung model under serum-free conditions

Aims: To better understand the parameters that govern spore dissemination after lung exposure using in vitro cell systems. Methods and Results: We evaluated the kinetics of uptake, germination and proliferation of B. anthracis Sterne spores in association with human primary lung epithelial cells, Calu-3, and A549 cell lines. We also analyzed the influence of various cell culture media formulations related to spore germination. Conclusions: We found negligible spore uptake by epithelial cells, but germination and proliferation of spores in the extracellular environment was evident, and was appreciably higher in A549 and Calu-3 cultures than in primary epithelial cells. Additionally, our results revealed spores in association with primary cells submerged in cell culture media germinated 1 h

Powell, Joshua D.↗

Construction of an in vitro primary lung co-culture platform derived from New Zealand white rabbits

We report the construction of an in vitro three dimensional (3D) co-culture platform consisting of differentiated lung epithelial cells and monocytes from New Zealand white rabbits. Rabbit lung epithelial cells were successfully grown at air-liquid interface, produced mucus, and expressed both sialic acid alpha-2,3 and alpha-2,6. Blood-derived CD14+ monocytes were deposited above the epithelial layer resulting in the differentiation of a subset of monocytes into CD11c+ cells within the co-culture. These proof-of-concept findings provide a convenient means to comparatively study in vitro versus in vivo rabbit lung responses as they relate to inhalation or lung-challenge studies.

lung↗

Biodetection Technologies for First Responders: 2014 Edition

This report summarizes commercially-available, hand-portable technologies that can be used by first responders in the field. This is not meant to be an exhaustive list, nor an endorsement of any technology described herein. Rather, this report is meant to provide useful information about available technologies to help end-users make informed decisions about biodetection technology procurement and use. Information listed in this report is primarily vendor-provided; however, where possible it has been supplemented with additional information obtained from publications, reports, and websites. Manufacturers were given the chance to review summaries of their technologies from August through November 2013 to verify the accuracy of technical specifications, available references, and pricing.

biodefense↗

Evaluation of the FilmArray® system for detection of Bacillus anthracis, Francisella tularensis, and Yersinia pestis

To evaluate the sensitivity and specificity of the Idaho Technologies FilmArray® Biothreat Panel for the detection of Bacillus anthracis (Ba), Francisella tularensis (Ft), and Yersinia pestis (Yp) DNA, and demonstrate the detection of Ba spores. Methods and Results: DNA samples from Ba, Ft and Yp strains and near-neighbors, and live Ba spores were analyzed using the Biothreat Panel, a multiplexed PCR-based assay for 17 pathogens and toxins. Sensitivity studies with DNA suggest a limit of detection of 250 genome equivalents (GEs) per sample. Furthermore, the correct call of Ft, Yp or Bacillus species was made in 63 of 72 samples tested at 25 GE or less. With samples containing 25 Ba Sterne spores, at least one of the two possible Ba markers were identified in all samples tested. We observed no cross-reactivity with near-neighbor DNAs.

Biodetection, PCR, hand portable, pathogens, biote↗

Defining cell culture conditions to improve human norovirus infectivity assays

Significant difficulties remain for determining whether human noroviruses (hNoV) recovered from water, food, and environmental samples are infectious. Three-dimensional tissue culture of human intestinal cells has shown promise in developing an infectivity assay, but reproducibility, even within a single laboratory, remains problematic. From the literature and our observations, we hypothesized that the common factors that leads to more reproducible hNoV infectivity in vitro requires that the cell line be 1) of human gastrointestinal origin, 2) expresses apical microvilli, and 3) be a positive secretor cell line. The C 2 BBe1 cell line, which is a brush-border producing clone of Caco-2, meets these three criteria. When challenged with Genogroup II viruses, we observed a 2 Log10 increase in viral RNA titer. A passage experiment with GII viruses showed evidence of the ability to propagate hNoV by both reverse transcription quantitative PCR (qRT-PCR) and microscopy. Using 3-D C 2 BBe1 cells improves reproducibility of the infectivity assay for hNoV, but the assay can still be variable. Two sources of variability include the cells themselves (mixed phenotypes of small and large intestine) and initial titer measurements using quantitative reverse transcription PCR (qRT-PCR) that measures all RNA vs. plaque assays that measure infectious virus.

C2BBe1 cells↗

Biodetection Technologies for First Responders

In a white powder scenario, there are a large number of field-deployable assays that can be used to determine if the suspicious substance contains biological material and warrants further investigation. This report summarizes commercially available technologies that are considered hand portable and can be used by first responders in the field. This is not meant to be an exhaustive list, nor do the authors endorse any of the technologies described herein. Rather, it is meant to provide useful information about available technologies to help end-users make informed decisions about biodetection technology procurement and use.

Baird, Cheryl L.↗