Search NASA⌕ Search

Engineering topics

Strickland, Chris

Publications and source records attributed to Strickland, Chris.

The EGS Collab project: Outcomes and lessons learned from hydraulic fracture stimulations in crystalline rock at 1.25 and 1.5 km depth

With the goal of better understanding stimulation in crystalline rock for improving enhanced geothermal systems (EGS), the EGS Collab Project performed a series of stimulations and flow tests at 1.25 and 1.5 km depths. The tests were performed in two well-instrumented testbeds in the Sanford Underground Research Facility in Lead, South Dakota, United States. The testbed for Experiment 1 at 1.5 km depth contained two open wells for injection and production and six instrumented monitoring wells surrounding the targeted stimulation zone. Four multi-step stimulation tests targeting hydraulic fracturing and nearly year-long ambient temperature and chilled water flow tests were performed in Experiment 1. The testbed for Experiments 2 and 3 was at 1.25 km depth and contained five open wells in an outwardly fanning five-spot pattern and two fans of well-instrumented monitoring wells surrounding the targeted stimulation zone. Experiment 2 targeted shear stimulation, and Experiment 3 targeted low-flow, high-flow, and oscillating pressure stimulation strategies. Hydraulic fracturing was successful in Experiments 1 and 3 in generating a connected system wherein injected water could be collected. However, the resulting flow was distributed dynamically, and not entirely collected at the anticipated production well. Thermal breakthrough was not observed in the production well, but that could have been masked by the Joule-Thomson effect. Shear stimulation in Experiment 2 did not occur - despite attempting to pressurize the fractures most likely to shear - because of the inability to inject water into a mostly-healed fracture, and the low shear-to-normal stress ratio. The EGS Collab experiments are described to provide a background for lessons learned on topics including induced seismicity, the correlation between seismicity and permeability, distributed and dynamic flow systems, thermoelastic and pressure effects, shear stimulation, local geology, thermal breakthrough, monitoring stimulation, grouting boreholes, modeling, and system management.

15 - GEOTHERMAL ENERGY↗

EGS Collab Experiment 3: 4100 Tensile Stimulation and Thermal Circulation Testing

These data and test descriptions are from a set of primarily tensile hydraulic-fracture stimulations in wells E2-TC and E2-TU and a subsequent chilled water circulation test conducted by injecting in well E2-TU on the 4100 level of the Sandford Underground Research Facility (SURF). Stimulations were carried out between April and May of 2022. The thermal circulation test ran semi-continuously from May 19 through August 26, 2022, though chilled water injection began on June 3. More information about the test, rationale, and processing of data is available on the EGS Collab project page, which is linked below.

15 GEOTHERMAL ENERGY↗

Dissolved oxygen sensor in an automated hyporheic sampling system reveals biogeochemical dynamics

Many river corridor systems frequently experience rapid variations in river stage height, hydraulic head gradients, and residence times. The integrated hydrology and biogeochemistry of such systems is challenging to study, particularly in their associated hyporheic zones. Here we present an automated system to facilitate 4-dimensional study of dynamic hyporheic zones. It is based on combining real-time in-situ and ex-situ measurements from sensor/sampling locations distributed in 3-dimensions. A novel dissolved oxygen (DO) sensor was integrated into the system during a small scale study. We measured several biogeochemical and hydrologic parameters at three subsurface depths in the riverbed of the Columbia River in Washington State, USA, a dynamic hydropeaked river corridor system. During the study, episodes of significant DO variations (~+/- 4 mg/l) were observed, with minor variation in other parameters (e.g., <~+/-0.15 mg/l NO 3 ). DO concentrations were related to hydraulic head gradients, showing both hysteretic and non-hysteretic relationships with abrupt (hours) transitions between the two types of relationships. The observed relationships provide a number of hypotheses related to the integrated hydrology and biogeochemistry of dynamic hyporheic zones. We suggest that preliminary high-frequency monitoring is advantageous in guiding the design of long term monitoring campaigns. The study also demonstrated the importance of measuring multiple parameters in parallel, where the DO sensor provided the key signal for identifying/detecting transient phenomena.

54 ENVIRONMENTAL SCIENCES↗

Field Test Bed for Vadose-Zone Monitoring Approaches - 20404

In the Central Plateau at the U.S. Department of Energy Hanford Site, a large inventory of contaminants resides in unsaturated sediments within the approximately 100-meter-thick vadose zone, posing a potential continuing risk to groundwater. Vadose zone remedies used to address these contaminants will require performance monitoring to provide feedback during implementation and for long-term verification that remedial action objectives have been met. Passive approaches may also need long-term monitoring to demonstrate that the flux of contaminants from the vadose zone to the groundwater are below thresholds established to meet groundwater protection goals. Collection of physical (e.g., groundwater or sediment) samples is a common method for identifying contaminant concentration distributions, but this approach is limited by the number of locations and the frequency with which data can be collected. In situ vadose zone measurements have evolved over the past few years to include key measurements of water content, soil water pressure, temperature, and chemical concentration. However, the current generation of sensors is designed for relatively short-term use in near-surface soils or sediments. Geophysical methods have been evolving but are also limited in that they have not been designed for the specific long-term vadose zone monitoring needs at the Hanford Site. Overall, monitoring under unsaturated conditions can be difficult due to the need to install and maintain instrumentation over a large area and depth and the need to identify preferential flow pathways due to geologic and chemical heterogeneities over long periods. Thus, a vadose zone monitoring test bed was initiated to address these challenges and identify cost-effective approaches for implementation and postclosure monitoring of the deep vadose zone. The monitoring test bed is expected to provide valuable field-scale information for the design of vadose zone monitoring systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗