The Effect of Neutron Irradiation on the Fracture Toughness of Graphite

As part of our irradiated graphite recycle program a small quantity of PCEA grade graphite was irradiated in the High Flux Isotope Reactor (HFIR) at ORNL. The graphite will provide the raw material for future recycle experiments. The geometry of the irradiated graphite allowed us to study the effects of neutron irradiation on the Critical Stress Intensity Factor, KIc, of graphite. The specimens where irradiated in two groups of 6 at an irradiation temperature of 900 C in rabbit capsules to doses of 6.6 and 10.2 DPA, respectively. Following a full suite of pre-and post-irradiation examination, which included dimensions, mass, electrical resistivity, elastic constants, and thermal expansion (to 800 C) the samples were notched and tested to determine their KIc using the newly approved ATSM test method for SENB fracture toughness of graphite. Here we report the irradiation induced changes in the dimensions, elastic constants, resistivity, and coefficient of thermal expansion of PCEA graphite. Moreover, irradiation induced changes in the Critical Stress Intensity Factor, KIc, or fracture toughness, are reported and discussed. Very little work on the effect of neutron irradiation on the fracture toughness of graphite has previously be performed or reported.

fracture toughness↗

Status of Initial Assessment of Physical and Mechanical Properties of Graphite Grades for NGNP Appkications

Current candidate graphite grades for the core structures of NGNP include grades NBG-17, NBG-18, PCEA and IG-430. Both NBG-17 and NBG-18 are manufactured using pitch coke, and are vibrationally molded. These medium grain products are produced by SGL Carbon SAS (France). Tayo Tanso (Japan) produces IG-430 which is a petroleum coke, isostatically molded, nuclear grade graphite. And PCEA is a medium grain, extruded graphite produced by UCAR Carbon Co. (USA) from petroleum coke. An experimental program has been initiated to develop physical and mechanical properties data for these current candidate graphites. The results will be judged against the requirements for nuclear grade graphites set forth in ASTM standard D 7219-05 "Standard Specification for Isotropic and Near-isotropic Nuclear Graphites". Physical properties data including thermal conductivity and coefficient of thermal expansion, and mechanical properties data including tensile, compressive and flexural strengths will be obtained using the established test methods covered in D-7219 and ASTM C 781-02 "Standard Practice for Testing Graphite and Boronated Graphite Components for High-Temperature Gas-Cooled Nuclear Reactors". Various factors known to effect the properties of graphites will be investigated. These include specimen size, spatial location within a graphite billet, specimen orientation (ag and wg) within a billet, and billet-to-billet variations. The current status of the materials characterization program is reported herein. To date billets of the four graphite grades have been procured, and detailed cut up plans for obtaining the various specimens have been prepared. Particular attention has been given to the traceability of each specimen to its spatial location and orientation within a billet.

01 COAL, LIGNITE, AND PEAT↗

A Study of the Annealing Behavior of Neutron Irradiated Graphite

Recycle is being considered as a disposal option for irradiated graphite from gas cooled reactors. Thermal annealing was performed on irradiated graphite samples to establish what fraction of in-crystal (displacement damage) and ex-crystal (pore generation) damage could be recovered. The sample dimensions and electrical resistivity were measured after isochronal annealing at 500, 1000, 1500, and 2000 C. Sample dimensions were unaffected by annealing. Some fraction of the resistivity was unannealable at 2000 C, this behavior which was attributed to (a) structural changes resulting from pore generation (also causing dimensions to be unaffected by annealing), or, (b) defect structures in irradiated graphite that persist even at an annealing temperature of 2000 C. The resistivity annealing behavior was different in low irradiation temperature samples, Tirr<~400 C and high irradiation temperature samples Tirr > ~400 C, which indicated defect structures established during irradiation were different in these two temperature regimes. Moreover, the extent of recovery was much greater in the specimens with higher irradiation temperatures, and was small for lower dose low temperature specimens. Evidently, some in-crystal defects that scatter or trap electrons are still present in the crystal lattice after annealing and their tenacity depends upon the irradiation temperature and accumulated neutron dose.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nuclear Graphite - Fracture Behavior and Modeling

Evidence for the graphite fracture mechanism is reviewed and discussed. The roles of certain microstructural features in the graphite fracture process are reported. The Burchell fracture model is described and its derivation reported. The successful application of the fracture model to uniaxial tensile data from several graphites with widely ranging structure and texture is reported. The extension of the model to multiaxial loading scenarios using two criteria is discussed. Initially, multiaxial strength data for H-451 graphite were modeled using the fracture model and the Principle of Independent Action. The predicted 4th stress quadrant failure envelope was satisfactory but the 1st quadrant predictions were not conservative and thus were unsatisfactory. Multiaxial strength data from the 1st and 4th stress quadrant for NBG-18 graphite are reported. To improve the conservatism of the predicted 1st quadrant failure envelope for NBG-18 the Shetty criterion has been applied to obtain the equivalent critical stress intensity factor, KIc (Equi), for each applied biaxial stress ratio. The equivalent KIc value is used in the Burchell fracture model to predict the failure envelope. The predicted 1st stress quadrant failure envelope is conservative and thus more satisfactory than achieved previously using the fracture model combined with the Principle of Independent Action.

36 MATERIALS SCIENCE↗

Characterization of Mechanical Properties of Nuclear Graphite Using Subsize Specimens and Reusing Tested Specimens

The mechanical properties of NBG-18 nuclear grade graphite have been characterized using small specimen test techniques and statistical treatment on the test results. New fracture strength and toughness test techniques were developed to use subsize cylindrical specimens with glued heads and to reuse their broken halves. Three sets of subsize cylindrical specimens with the different diameters of 4 mm, 8 mm, and 12 mm were tested to obtain tensile fracture strength. The longer piece of the broken halves was cracked from side surfaces and tested under three-point bend loading to obtain fracture toughness. Both the strength and fracture toughness data were analyzed using Weibull distribution models focusing on size effect. The mean fracture strength decreased from 22.9 MPa to 21.5 MPa as the diameter increased from 4 mm to 12 mm, and the mean strength of 15.9 mm diameter standard specimen, 20.9 MPa, was on the extended trend line. These fracture strength data indicate that in the given diameter range the size effect is not significant and much smaller than that predicted by the Weibull statistics-based model. Further, no noticeable size effect existed in the fracture toughness data, whose mean values were in a narrow range of 1.21 1.26 MPa. The Weibull moduli measured for fracture strength and fracture toughness datasets were around 10. It is therefore believed that the small or negligible size effect enables to use the subsize specimens and that the new fracture toughness test method to reuse the broken specimens to help minimize irradiation space and radioactive waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗