Method for real-time inspection of structural components

A multi-mode approach for real-time inspection of structural components may be applied to rapid, wide area measurement of thickness of thick plate-like structures using full-field multi-mode response measurement and analysis. The approach may allow estimation of thickness from full-field multi-mode response to single-tone ultrasonic excitation in thick plates. The approach may utilize wavenumber information across all available wave modes in order to make wavenumber spectroscopy sensitive to changes in thickness for a broader range of nominal initial thicknesses.

Stull, Nicholas D.↗

On the theoretical limitations in estimating thickness of a plate-like structure from a full-field single-tone response Lamb wave measurement

A persistent question in wavenumber analysis in the estimation of thickness from a steady-state wave field is identifying the theoretical sensitivity of the system. Here, a well-known trade-off between spatial frequency/wavenumber resolution and thickness resolution exists. The current work presents a calculation of the Cramer-Rao Lower bound (CRLB), specifically as applied to thickness estimates, for a 2-dimensional multi-mode waveform in Gaussian noise. Cases of near-field and far-field excitation are considered, and transducer position with respect to the scan area is also varied. Additionally, we consider the CRLB in a plate with multiple sources, simulated as sources placed on the boundary of the plate. We conclude by presenting the CRLB values in terms of frequency for various thicknesses, and by presenting optimal excitation frequencies for a nominal thickness, based on the CRLB.

47 OTHER INSTRUMENTATION↗

On a Method For Reconstructing Computed Tomography Datasets from an Unstable Source

As work continues in neutron computed tomography, at Los Alamos Neutron Science Center (LANSCE) and other locations, source reliability over the long imaging times is an issue of increasing importance. Moreover, given the time commitment involved in a single neutron image, it is impractical to simply discard a scan and restart in the event of beam instability. In order to mitigate the cost and time associated with these options, strategies are presented in the current work to produce a successful reconstruction of computed tomography data from an unstable source. The present work uses a high energy neutron tomography dataset from a simulated munition collected at LANSCE to demonstrate the method, which is general enough to be of use in conjunction with unstable X-ray computed tomography sources as well.