Soft X-ray measurements of transport and MHD activity in the core and edge NSTX plasma (Final Technical Report)

A comprehensive suite of innovative diagnostic instrumentation and techniques has been developed by the Johns Hopkins collaboration for measurements of transport and MHD activity in the core and edge of the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Laboratory (PPPL). These include ultrafast multi-energy poloidal soft X-ray arrays, high spatial resolution multi-energy tangential soft X-ray arrays, high spectral resolution transmission grating imaging VUV spectrometers and ultrafast bolometric arrays, which measure over a broad range of spatial, spectral, and temporal scales the emission from ohmic, RF, and beam driven NSTX plasmas. The instrumentation was designed to fulfill the specific measurement needs of the Spherical Torus (ST) magnetic fusion concept and is accompanied by a comprehensive set of numerical tools for data analysis and modeling, aimed at determining as many as possible plasma parameters and at extracting as much as possible physics information from NSTX experiments. The Johns Hopkins diagnostics have been and continue to be instrumental for essentially all the NSTX experiments. In addition, our own research and experiments using these diagnostics has led over the years to fundamental conclusions for the ST fusion physics, such as the establishment of near neoclassical impurity transport in the NSTX core and edge plasma, and the critical role of the Global Alfven Eigenmode (GAE) MHD activity for the ST core electron thermal transport. The Johns Hopkins Diagnostics continue to be operational on the upgraded NSTX-U and will provide key plasma information in its upcoming high field, current and power experimental campaigns. The present report summarizes the main technical characteristics and measurement capabilities of the diagnostic instrumentation and methods developed within our research and describes a key physics result achieved during this research. Success in our research was made possible also by the excellent support and cooperation of the NSTX research team and of PPPL researchers, who are warmly acknowledged here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Ray Phase Contrast Imaging for Dynamic Material Mix Experiments, LAO-003-17, Year 3 of 3

X-ray phase contrast imaging with transmission gratings for density profile measurements has been developed and tested for dynamic experimental applications. Talbot-Lau x-ray deflectometry is a new method of measuring x-ray refraction in addition to attenuation and ultrasmall-angle scattering that has recently been developed for static imaging, primarily for medical and industrial applications. To obtain density profiles from fast-evolving systems, we must use a flash x-ray source with a spot size much larger than the continuous microfocus sources of static imaging systems, and we can obtain only a single exposure. The challenges to measuring electron density profiles of two mixed elements from a single-image, low spatial resolution system are addressed, and initial results from the first dynamic experiments with one such system, conducted on a gas launcher at the end of FY 2018 and beginning of FY 2019, are presented. In FY 2019, we designed and built a new deflectometer designed for detonator experiments to test new techniques to improve the sensitivity and reliability of the diagnostic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of Talbot–Lau x-ray deflectometry in the pulsed power environment using a copper X-pinch backlighter

A Talbot–Lau x-ray deflectometer can map electron density gradients in high energy density plasmas, as well as provide information about plasma elemental composition through single-image x-ray refraction and attenuation measurements. A new adaptation to a pulsed power environment used backlighting from copper X-pinches, allowing for electron density mapping of a low-Z object. Even though the X-pinch backlighter is not properly optimized for emitting x-rays in terms of source size and photon fluence, Moire fringe patterns with contrast up to 14% and fringe shift due to refraction on a beryllium object are obtained. Due to the proximity of the deflectometer with the X-pinch (~6 cm), it is shown that a protective filter is required to avoid damage in the closest (i.e., source) grating due to both plasma debris and mechanical shock. Regarding grating survival, these did not show any damage due to the intense magnetic field or heating induced by plasma radiation. Electron density on beryllium was measured with a difference lower than 16%. The areal electron density mapping of the sample was limited by source size characteristics, in similarity to transmission radiography. These results show the potential of plasma electron density as well as material mapping through Talbot–Lau x-ray deflectometry in a pulsed power environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray backlighter requirements for refraction-based electron density diagnostics through Talbot-Lau deflectometry

We report that Talbot-Lau x-ray interferometers can map electron density gradients in High Energy Density (HED) samples. In the deflectometer configuration, it can provide refraction, attenuation, elemental composition, and scatter information from a single image. X-ray backlighters in Talbot-Lau deflectometry must meet specific requirements regarding source size and x-ray spectra, amongst others, to accurately diagnose a wide range of HED experiments. 8 keV sources produced in the high-power laser and pulsed power environment were evaluated as x-ray backlighters for Talbot-Lau x-ray deflectometry. In high-power laser experiments, K-shell emission was produced by irradiating copper targets (500 × 500 × 12.5 μm 3 foils, 20 μm diameter wire, and >10 μm diameter spheres) with 30 J, 8-30 ps laser pulses and a 25 μm copper wire with a 60 J, 10 ps laser pulse. In the pulsed power environment, single (2 × 40 μm) and double (4 × 25 μm) copper x-pinches were driven at ~1 kA/ns. Lastly, moiré fringe formation was demonstrated for all x-ray sources explored, and detector performance was evaluated for x-ray films, x-ray CCDs, and imaging plates in context of spatial resolution, x-ray emission, and fringe contrast.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nevada National Security Site Site-Directed Research and Development Report (FY 2018 Annual Report)

This report compiles multiple articles describing activities developed and performed under the Site-Directed Research and Development Program for the benefit the Nation during Fiscal Year 2018. Sustained investment and ongoing core innovation are the keys to successful research and development programs. These elements drive the Site-Directed Research and Development (SDRD) Program and provide solutions to some of the most challenging problems our nation and our allies face. Our Nevada enterprise, consisting of both our management and operating entity and our NNSA field office, is aggressively investing in SDRD and injecting innovation through strategic partnerships. Our partnerships with universities, industry, and our sister institutions within the National Nuclear Security Administration (NNSA) build upon our core capabilities and allow us to create innovative solutions to support our mission requirements. In 2018, we raised the investment level of SDRD for only the second time in the history of the program. Nearly at our congressionally authorized limit, SDRD has substantial resources to successfully address numerous issues. Investment is only one part of the equation; innovation is generated through collaborations that bring discovery and provide the “technical differentiation” and the return on investment we seek. This report demonstrates an enduring theme of how partnerships help us drive the best outcomes and provide the maximum impact possible, while using our resources efficiently.

36 MATERIALS SCIENCE↗

Talbot–Lau x-ray deflectometry phase-retrieval methods for electron density diagnostics in high-energy density experiments

Talbot–Lau x-ray interferometry uses incoherent x-ray sources to measure refraction index changes in matter. These measurements can provide accurate electron density mapping through phase retrieval. An adaptation of the interferometer has been developed in order to meet the specific requirements of high-energy density experiments. This adaptation is known as a moiré deflectometer, which allows for single-shot capabilities in the form of interferometric fringe patterns. The moiré x-ray deflectometry technique requires a set of object and reference images in order to provide electron density maps, which can be costly in the high-energy density environment. In particular, synthetic reference phase images obtained ex situ through a phase-scan procedure, can provide a feasible solution. To test this procedure, an object phasemap was retrieved from a single-shot moiré image obtained from a plasma-produced x-ray source. A reference phase map was then obtained from phase-stepping measurements using a continuous x-ray tube source in a small laboratory setting. Ultimately, the two phase maps were used to retrieve an electron density map. A comparison of the moiré and phase-stepping phase-retrieval methods was performed to evaluate single-exposure plasma electron density mapping for high-energy density and other transient plasma experiments. It was found that a combination of phase-retrieval methods can deliver accurate refraction angle mapping. Once x-ray backlighter quality is optimized, the ex situ method is expected to deliver electron density mapping with improved resolution. The steps necessary for improved diagnostic performance are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Phase Contrast Imaging for Dynamic Material Mix Experiments, LAO-003-17, Year 1 of 2

This presentation describes the challenges to measuring electron density profiles of two mixed elements from a single-image, low spatial-resolution system, and initial results from the first of these systems, built and successfully tested on the bench in Fiscal Year (FY) 2017. This system will be installed on a gas gun and tested during dynamic shock physics experiments in FY 2018.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge state distribution and emission characteristics in a table top reflex discharge—Effect of ion confinement and electrons accelerated across the sheath

Tabletop reflex discharges in a Penning geometry have many applications including ion sources and eXtreme Ultra-Violet (XUV) sources. The presence of primary electrons accelerated across the cathode sheaths is responsible for the distribution of ion charge states and of the unusually high XUV brightness of these plasmas. Absolutely calibrated space resolved XUV spectra from a table top reflex discharge operating with Al cathodes and Ne gas are presented. The spectra are analyzed with a new and complete model for ion charge distribution in similar reflex discharges. The plasma in the discharge was found to have a density of ∼10{sup 18 }m{sup −3} with a significant fraction >0.01 of fast primary electrons. The implications of the new model on the ion states achievable in a tabletop reflex plasma discharge are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an x-ray Talbot-Lau moiré deflectometer for fast density profile measurements of dense plasmas generated by beam-target interactions

We report that for the first time an x-ray Talbot-Lau moiré deflectometer is being developed that will use a flash tube source and fast detector for dynamic density gradient measurements. In Talbot-Lau moiré deflectometry, an x-ray grating makes an image of itself on a second grating (the Talbot effect) to produce a moiré pattern on a detector. The test object is placed between these gratings, with variations in index of refraction changing the pattern. A third grating in front of an incoherent x-ray source produces an array of coherent sources. With a 150 kV x-ray flash tube as the source, the gratings are placed in a glancing angle setup for performance at ~60 keV. The detector is a gated CCD with a fast scintillator for x-ray conversion. This diagnostic, designed for the Dual-Axis Radiographic Hydrodynamic Test facility (DARHT) at Los Alamos National Laboratory, measures the density profile of dense plasma plumes ejected from beam-target interactions. DARHT has two high-current, pulsed, inductive linear electron accelerators with bremsstrahlung targets at the end of each beam line to create 2-D radiographic images of hydrodynamic tests. One multi-pulse accelerator has up to four beam pulses striking the same target within 2 μs. Computer simulations that model target evolution and ejected material between pulses are used to design these targets for optimal radiographic performance; the x-ray deflectometer will directly measure density gradients in the ejected plumes and provide the first experimental constraints to these models. During the first year, currently underway, the diagnostic systems are being designed. In year two, the flash tube and fast detector will be deployed at DARHT for radiographic imaging while the deflectometer is built and tested on the bench with a continuous source. In year three, the fast deflectometer will be installed on DARHT and density measurements will be performed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray Moiré deflectometry using synthetic reference images

Moiré fringe deflectometry with grating interferometers is a technique that enables refraction-based x-ray imaging using a single exposure of an object. To obtain the refraction image, the method requires a reference fringe pattern (without the object). Our study shows that, in order to avoid artifacts, the reference pattern must be exactly matched in phase with the object fringe pattern. In experiments, however, it is difficult to produce a perfectly matched reference pattern due to unavoidable interferometer drifts. We present a simple method to obtain matched reference patterns using a phase-scan procedure to generate synthetic Moiré images. As a result, the method will enable deflectometric diagnostics of transient phenomena such as laser-produced plasmas and could improve the sensitivity and accuracy of medical phase-contrast imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of thermal helium beam and line-ratio fast diagnostic on the National Spherical Torus Experiment-Upgrade

A 1-D kinetic collisional radiative model (CRM) with state-of-the-art atomic data is developed and employed to simulate line emission to evaluate the Thermal Helium Beam (THB) diagnostic on NSTX-U. This diagnostic is currently in operation on RFX-mod, and it is proposed to be installed on NSTX-U. The THB system uses the intensity ratios of neutral helium lines 667.8, 706.5, and 728.1 nm to derive electron temperature (eV ) and density (cm –3 ) profiles. The purpose of the present analysis is to evaluate the applications of this diagnostic for determining fast (~4 μs) electron temperature and density radial profiles on the scrape-off layer (SOL) and edge regions of NSTX-U that are needed in turbulence studies. The diagnostic is limited by the level of detection of the 728.1 nm line, which is the weakest of the three. In conclusion, this study will also aid in future design of a similar 2-D diagnostic systems on the divertor.

97 MATHEMATICS AND COMPUTING↗

VUV/XUV measurements of impurity emission in plasmas with liquid lithium surfaces on LTX [VUV/XUV measurements of low recycling plasmas with liquid lithium surfaces on LTX]

The VUV/XUV spectrum has been measured on the Lithium Tokamak eXperiment (LTX) using a transmission grating imaging spectrometer (TGIS) coupled to a direct-detection x-ray charge-coupled device camera. TGIS data show significant changes in the ratios between the lithium and oxygen impurity line emission during discharges with varying lithium wall conditions. Lithium coatings that have been passivated by lengthy exposure to significant levels of impurities contribute to a large O/Li ratio measured during LTX plasma discharges. Furthermore, previous results have indicated that a passivated lithium film on the plasma facing components will function as a stronger impurity source when in the form of a hot liquid layer compared to a solid lithium layer. However, recent TGIS measurements of plasma discharges in LTX with hot stainless steel boundary shells and a fresh liquid lithium coating show lower O/Li impurity line ratios when compared to discharges with a solid lithium film on cool shells. In conclusion, these new measurements help elucidate the somewhat contradictory results of the effects of solid and liquid lithium on plasma confinement observed in previous experiments.

36 MATERIALS SCIENCE↗

SXR-XUV Diagnostics for Edge and Core of Magnetically Confined Plasmas

The present report summarizes the results obtained during a one-year extension of DoE grant “SXR-XUV Diagnostics for Edge and Core of Magnetically Confined Plasmas”, at Johns Hopkins University, aimed at completing the development of a new type of magnetic fusion plasma diagnostic, the XUV Transmission Grating Imaging Radiometer (TGIR). The TGIR enables simultaneous spatially and spectrally resolved measurements of the XUV/VUV radiated power from impurities in fusion plasmas, with high speed. The instrument was successfully developed and qualified in the laboratory and in experiments on a tokamak. Its future applications will be diagnostic of the impurity content and transport in the divertor and edge of advanced magnetic fusion experiments, such as NSTX Upgrade.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Talbot-Lau X-ray Phase-Contrast Research at Johns Hopkins

The Talbot-Lau (T-L) grating interferometer enables X-ray differential phase-contrast (DPC) imaging with low coherence conventional X-ray tubes, being thus attractive for medical and other applications. We studied several variations of the conventional T-L interferometer design. First, to extend the T-L method to high X-ray energy we developed a symmetric interferometer having gratings inclined at a glancing angle (GAI). This simple setup enables achieving high fringe contrast up to 80 kVp or more. The high GAI contrast in turn enabled demonstrating for the first time DPC-CT of soft tissues with clinically compatible X-ray dose and energy. Industrial and security applications of the GAI appear also possible. Further on, we studied high magnification T-L interferometry for electron density diagnostic in high energy density plasmas. High magnification refraction radiography with laser driven backlighters can help understand inertial confinement fusion experiments for instance. For plasma diagnostic using a single radiographic image we develop Moiré fringe deflectometry. We also extended the T-L method below 10 keV using membrane and free standing gratings. Lastly, we explored using grazing incidence micro-periodic mirrors instead of gratings in the T-L interferometers. These enable in principle achieving very small interferometer periods over a broad energy range, at the price of a narrow field of view in one dimension. The possibility of using these designs for DPC imaging of materials under extreme conditions will also be examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual transmission grating based imaging radiometer for tokamak edge and divertor plasmas

The designs of single transmission grating based extreme ultraviolet (XUV) and vacuum ultraviolet (VUV) imaging spectrometers can be adapted to build an imaging radiometer for simultaneous measurement of both spectral ranges. This paper describes the design of such an imaging radiometer with dual transmission gratings. The radiometer will have an XUV coverage of 20-200 A with a {approx}10 A resolution and a VUV coverage of 200-2000 A with a {approx}50 A resolution. The radiometer is designed to have a spatial view of 16 Degree-Sign , with a 0.33 Degree-Sign resolution and a time resolution of {approx}10 ms. The applications for such a radiometer include spatially resolved impurity monitoring and electron temperature measurements in the tokamak edge and the divertor. As a proof of principle, the single grating instruments were used to diagnose a low temperature reflex discharge and the relevant data is also included in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗