Search NASA⌕ Search

Engineering topics

Stutzman, M. L.

Publications and source records attributed to Stutzman, M. L..

An overview of how parity-violating electron scattering experiments are performed at CEBAF

Parity-violating electron-scattering experiments represent an important focus of the nuclear physics experimental program at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. These experiments pose significant challenges because the scattering asymmetries can be very small, of the order parts-per-million and smaller. To succeed, the properties of the electron beam such as current, position, size and energy, must be very nearly identical in the two electron-polarization spin states (parallel and anti-parallel relative to the direction of beam motion at the scattering target). This paper describes the origins of unwanted helicity-correlated beam asymmetries present on the electron beam and methods to minimize them to acceptable levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HIGH VOLTAGE DESIGN AND EVALUATION OF WIEN FILTERS FOR THE CEBAF 200 keV INJECTOR UPGRADE

High-energy nuclear physics experiments at the Jefferson Lab Continuous Electron Beam Accelerator Facility (CEBAF) require highly spin-polarization electron beams, produced from strained super-lattice GaAs photocathodes, activated to negative electron affinity in a photogun operating at 130 kV dc. A pair of Wien filter spin rotators in the injector defines the orientation of the electron beam polarization at the end station target. An upgrade of the CEBAF injector to better support the upcoming MOLLER experiment requires increasing the electron beam energy to 200 keV, to reduce unwanted helicity correlated intensity and position systematics and provide precise control of the polarization orientation. Our contribution describes design, fabrication and testing of the high voltage system to upgrade the Wien spin rotator to be compatible with the 200 keV beam. This required Solidworks modeling, CST and Opera electro- and magnetostatic simulations, upgrading HV vacuum feedthroughs, and assembly techniques for improving electrode alignment. The electric and magnetic fields required by the Wien condition and the successful HV characterization under vacuum conditions are also presented.

Palacios-Serrano, G.↗

Half-Metal Spin Filter for Highly Polarized Emission from GaAs Photocathodes

GaAs-based photocathodes are one of the major sources of spin-polarized electrons and are crucial for the upcoming Electron-Ion collider experiments which includes study of proton spin and spin parity violation in the standard model. The theoretical polarization limit in unstrained GaAs photocathodes is 50 % but only 35 % is routinely achieved in experiments. Spin selective filtering allows to boost the spin polarization beyond the 50 % theoretical limit. In this work, first-principle electronic calculations using standard Density Functional Theory are performed to predict possible Heusler alloy half-metal candidates to be used as spin-filter. Simulations are also performed to investigate the half-metallicity as function of the magnetic spin direction. Several devices are experimentally fabricated using dedicated Molecular Beam Epitaxy growth system. We implemented Quantum Efficiency and Polarization testing of these half-metal/GaAs heterostructures using a dedicated Mott polarimeter system. Photoemission can also be seen on magnetically switching the spin-filter direction accompanied by a change in sign of the asymmetry which is a qualitative proof of the spin-filtering effect.

Poddar, S.↗

Improving the Operational Lifetime of the CEBAF Photo-Gun by Anode Biasing

The operating lifetime of GaAs-based photocathodes in DC high voltage electron photo-guns is dominated by the ionization rate of residual beamline gas molecules. In this work, experiments were performed to quantify the improvement in photocathode charge lifetime by biasing the photo-gun anode with a positive voltage, which repels ions generated downstream of the anode. The photo-cathode charge lifetime improved by almost a factor of two when the anode was biased compared to the usual grounded configuration. Simulations were performed using the particle tracking code General Particle Tracer (GPT) with a new custom element. The simulation results showed that both the number and energy of ions play a role in the pattern of QE degradation. The experiment results and conclusions supported by GPT simulations will be presented.

Yoskowitz, J. T.↗

Pressure Simulations for the EIC Interaction Region

Background detector rates in the Electron Ion Collider depend in part on the pressure in the interaction region. Materials choice, synchrotron radiation induced desorption, conditioning time and pumping configuration all affect the pressure in the system. Simulations of the region using Synrad and Molflow+ coupled simulation codes will be presented for various configruations and conditioning times.

Stutzman, M. L.↗