Search NASASearch

Engineering topics

Subramanian, R. S.

Publications and source records attributed to Subramanian, R. S..

At least 19 records

Thermocapillary Convection Due to a Stationary Bubble - A Paradox

We analyze the velocity and temperature fields at steady state due to thermocapillary convection around a gas bubble that is stationary in a liquid. A linear temperature field is imposed in the undisturbed liquid. Our interest is in investigating the effect of convective transport of momentum and energy on the velocity and temperature fields. We assume the pertinent physical properties to be constant, and that buoyant convection is negligible. Suitably defined Reynolds and Marangoni numbers are assumed to be small compared with unity. When both the Reynolds and Marangoni numbers are set equal to zero, a solution can be found. In this solution, far from the bubble, the velocity field decays as the inverse of the distance from the bubble, and the disturbance temperature field decays as the inverse of the square of this distance. We now attempt to obtain a solution when the Reynolds number is zero, but the Marangoni number is small, but non-zero, by a perturbation expansion in the Marangoni number. When the temperature field is expanded in a regular perturbation series in the Marangoni number, we show that the problem for the first correction field is ill-posed. The governing equation for this perturbation field contains an inhomogeneity, and the corresponding particular solution neither decays far from the bubble, nor can be canceled by a homogeneous solution. Additional information is included in the original extended abstract.

Balasubramaniam, R.

Thermocapillary Bubble Migration: Thermal Boundary Layers for Large Marangoni Numbers

The migration of an isolated gas bubble in an immiscible liquid possessing a temperature gradient is analyzed in the absence of gravity. The driving force for the bubble motion is the shear stress at the interface which is a consequence of the temperature dependence of the surface tension. The analysis is performed under conditions for which the Marangoni number is large, i.e. energy is transferred predominantly by convection. Velocity fields in the limit of both small and large Reynolds numbers are used. The thermal problem is treated by standard boundary layer theory. The outer temperature field is obtained in the vicinity of the bubble. A similarity solution is obtained for the inner temperature field. For both small and large Reynolds numbers, the asymptotic values of the scaled migration velocity of the bubble in the limit of large Marangoni numbers are calculated. The results show that the migration velocity has the same scaling for both low and large Reynolds numbers, but with a different coefficient. Higher order thermal boundary layers are analyzed for the large Reynolds number flow field and the higher order corrections to the migration velocity are obtained. Results are also presented for the momentum boundary layer and the thermal wake behind the bubble, for large Reynolds number conditions.

Balasubramaniam, R.

Thermocapillary migration of a small chain of bubbles

The quasistatic thermocapillary migration of a chain of two or three spherical bubbles in an unbounded fluid possessing a uniform temperature gradient is investigated in the limit of vanishing Reynolds and Peclet numbers. The line of bubble centers is permitted to be either parallel or perpendicular to the direction of the undisturbed temperature gradient. The governing equations are solved by a truncated-series, boundary-collocation technique. Results are presented which demonstrate the impact of the presence of other bubbles on a test bubble. In the three-bubble case, a simple pairwise-additive approximation is constructed from the reflections solution, and found to perform well except when the bubbles are close to each other. Also, features of the flow topology in the fluid are explored. Separated reverse flow wakes are found in the axisymmetric problem, and other interesting structures are noted for the case in which the line of centers is perpendicular to the applied temperature gradient. The observed flow structure is shown to be the result of superposition of simpler basic flows.

Wei, Huailiang

Bubble migration under the combined action of buoyancy and thermocapillarity

The migration of a gas bubble under the combined action of buoyancy and a downward temperature gradient is analyzed. Inertial effects are considered negligible, but allowance is made for convective transport of energy in the model. Results from a numerical solution of the governing equations are presented and discussed.

Merritt, Randy M.

Thermocapillary motion of bubbles and drops

An account is given of interface-driven motions of drops and bubbles. It is shown that even in the simplest cases, theory predicts exotic flow topologies. Attention is given to several unsolved problems that must be addressed both theoretically and experimentally.

Subramanian, R. S.

Physical Phenomena in Containerless Glass Processing

An investigation into the various physical phenomena of importance in the space experiments is under way. Theoretical models of thermocapillary flow in drops, thermal migration of bubbles and droplets, the motion of bubbles inside drops, and the migration of bubbles in rotating liquid bodies are being developed. Experiments were conducted on the migration of bubbles and droplets to the axis of a rotating liquid body, and the rise of bubbles in molten glass. Also, experiments on thermocapillary motion in silicone oils as well as glass melts were performed. Experiments are currently being conducted on the migration of bubbles in a thermal gradient, and on their motion inside unconstrained liquid drops in a rotating liquid.

Subramanian, R. S.

Experimental studies of glass refining

The basic components of the experimental apparatus were selected and acquired. Techniques were developed for the fabrication of the special crucibles necessary for the experiments. Arrangements were made for the analysis of glass and gas bubble samples for composition information. Donations of major equipment were received for this project from Owens, Illinois where a similar study had been conducted a few year ago. Decisions were made regarding the actual glass composition to be used, the gas to be used in the first experiments, and the temperatures at which the experiments should be conducted. A microcomputer was acquired, and work was begun on interfacing the video analyzer to it.

Subramanian, R. S.

Thermocapillary migration of bubbles and droplets

A discussion is presented concerning the motion of droplets in a surrounding fluid induced by a temperature gradient. Such 'thermocapillary migration' may be characterized as the tangential stress at the interface that is induced by the temperature gradient's variation of interfacial tension, causing motion in the neighboring fluid both inside and outside the droplet. As a result, the droplet moves in the direction of the pole with the lower interfacial tension. An analysis is conducted in the creeping flow limit, for the case of small Marangoni number values. The method of matched asymptotic expansions is used for the solution of the field equations.

Subramanian, R. S.

Motion driven by the interface

Due to the reduction in buoyant forces aboard orbiting spacecraft such as the Space Shuttle, fluid motion driven by gradients in interfacial tension will be important in the processing of materials in space. In this paper, preliminary results from a study of surface tension driven flow in a pendant drop are reported. The drop is heated from above, and the resulting temperature gradients on the drop surface give rise to interfacial tension gradients. These, in turn, drive a circulation in the drop which is made visible by suitable tracers. The velocities are measured using a video technique, and the data on core velocities are found to agree well with results from a predictive theoretical model.

Jayaraj, K.

Bubble migration in a rotating, liquid-filled sphere

Results and analysis of ground-based experiments performed to aid in designing experiments on the behavior of bubbles in a rotating liquid body on board the Shuttle in free fall are presented. Spherical shells filled with silicone oil containing a small gas bubble were spun and filmed by high speed motion picture photography. The rotation of the shell and the trajectory of the bubble motion were recorded and the film was exposed to a motion analyzer connected to a keypunch. The analyzer measured Cartesian coordinates as well as angle, frame number, and rotation rate. Optical correction equations were employed to determine the apparent bubble trajectory relative to an inertial frame of reference. An analytical model for the bubble motion was defined, yielding predictions of velocity and position at different times. Rotation of the fluid container is concluded to aid in centering the bubbles.

Annamalai, P.

Interaction effects in thermocapillary bubble migration

Two bubbles migrating along their line of centers under the influence of an imposed thermal gradient are considered in the quasi-static limit. Results are reported for representative values of the governing parameters.

Meyyappan, M.

The motion of bubbles inside drops in containerless processing

A theoretical model of thermocapillary bubble motion inside a drop, located in a space laboratory, due to an arbitrary axisymmetric temperature distribution on the drop surface was constructed. Typical results for the stream function and temperature fields as well as the migration velocity of the bubble were obtained in the quasistatic limit. The motion of bubbles in a rotating body of liquid was studied experimentally, and an approximate theoretical model was developed. Comparison of the experimental observations of the bubble trajectories and centering times with theoretical predictions lends qualified support to the theory.

Shankar, N.

Physical phenomena in containerless glass processing

Experiments were conducted on bubble migration in rotating liquid bodies contained in a sphere. Experiments were initiated on the migration of a drop in a slightly less dense continuous phase contained in a rotating sphere. A refined apparatus for the study of thermocapillar flow in a glass melt was built, and data were acquired on surface velocities in the melt. Similar data also were obtained from an ambient temperature fluid model. The data were analyzed and correlated with the aid of theory. Data were obtained on flow velocities in a pendant drop heated from above. The motion in this system was driven principally by thermocapillarity. An apparatus was designed for the study of volatilization from a glass melt.

Subramanian, R. S.

Bubble migration inside a liquid drop in a space laboratory

The design of experiments in materials processing for trials on board the Shuttle are described. Thermocapillary flows will be examined as an aid to mixing in the formation of glasses. Acoustically levitated molten glass spheres will be spot heated to induce surface flow away from the hot spot to induce mixing. The surface flows are also expected to cause internal convective motion which will drive entrained gas bubbles toward the hot spot, a process also enhanced by the presence of thermal gradients. The method is called fining, and will be augmented by rotation of the sphere to cause bubble migration toward the axes of rotation to form one large bubble which is more easily removed. Centering techniques to fix the maximum centering accuracy will also be tried. Ground-based studies of bubble migration in a rotating liquid and in a temperature gradient in a liquid drop are reviewed.

Annamalai, P.

Bubble motion in a rotating liquid body

The behavior of a single gas bubble inside a rotating liquid-filled sphere has been investigated analytically and experimentally as part of ground-based investigations aimed at aiding in the design and interpretation of Shuttle experiments. In the analysis, a quasi-static description of the motion of a bubble was developed in the limit of small values of the Taylor number. A series of rotation experiments using air bubbles and silicone oils were designed to match the conditions specified in the analysis, i.e., the bubble size, sphere rotation rate, and liquid kinematic viscosity were chosen such that the Taylor number was much less than unity. The analytical description predicts the bubble velocity and its asymptotic location. It is shown that the asymptotic position is removed from the axis of rotation.

Annamalai, P.

Thermocapillary motion of bubbles inside drops

A quasi-static analysis is performed for the thermocapillary motion of a bubble located inside a drop in free fall, with arbitrary axisymmetric temperature fields prescribed on the drop surface. It is shown that in the case of an axially symmetric temperature field, the bubble moves along the axis of symmetry toward the nearest warm pole. The bubble velocity as well as the velocity and temperature fields in the drop can be predicted on the basis of the quasi-static assumptions. An approximation is presented which adequately describes bubble migration velocities in the case where the ratio of the bubble radius to the drop radius is relatively small.

Shankar, N.

Experimental observation of the thermocapillary driven motion of bubbles in a molten glass under low gravity conditions

An experiment was carried out on board a Space Processing Applications Rocket with the aim of demonstrating bubble migration in molten glass due to a temperature gradient under low gravity conditions. During the flight, a sample of a sodium borate melt with a specific bubble array, contained in a platinum/fused silica cell, was subjected to a well defined temperature gradient for more than 4 minutes. Photographs taken at one second intervals during the experiment clearly show that the bubbles move toward the hot spot on the platinum heater strip. This result is consistent with the predictions of the theory of thermocapillary driven bubble motion.

Smith, H. D.

Surface tension driven flow in glass melts and model fluids

Surface tension driven flow has been investigated analytically and experimentally using an apparatus where a free column of molten glass or model fluids was supported at its top and bottom faces by solid surfaces. The glass used in the experiments was sodium diborate, and the model fluids were silicone oils. In both the model fluid and glass melt experiments, conclusive evidence was obtained to prove that the observed flow was driven primarily by surface tension forces. The experimental observations are in qualitative agreement with predictions from the theoretical model.

Mcneil, T. J.