Experimental and Computational Investigation of the Tip Clearance Flow in a Transonic Axial Compressor Rotor

Experimental and computational techniques are used to investigate tip clearance flows in a transonic axial compressor rotor at design and part speed conditions. Laser anemometer data acquired in the endwall region are presented for operating conditions near peak efficiency and near stall at 100% design speed and at near peak efficiency at 60% design speed. The role of the passage shock/leakage vortex interaction in generating endwall blockage is discussed. As a result of the shock/vortex interaction at design speed, the radial influence of the tip clearance flow extends to 20 times the physical tip clearance height. At part speed, in the absence of the shock, the radial extent is only 5 times the tip clearance height. Both measurements and analysis indicate that under part-speed operating conditions a second vortex, which does not originate from the tip leakage flow, forms in the endwall region within the blade passage and exits the passage near midpitch. Mixing of the leakage vortex with primary flow downstream of the rotor at both design and part speed conditions is also discussed.

Suder, Kenneth L.

Laser anemometer measurements in a transonic axial-flow fan rotor

Laser anemometer surveys were made of the 3-D flow field in NASA rotor 67, a low aspect ratio transonic axial-flow fan rotor. The test rotor has a tip relative Mach number of 1.38. The flowfield was surveyed at design speed at near peak efficiency and near stall operating conditions. Data is presented in the form of relative Mach number and relative flow angle distributions on surfaces of revolution at nine spanwise locations evenly spaced from hub to tip. At each spanwise location, data was acquired upstream, within, and downstream of the rotor. Aerodynamic performance measurements and detailed rotor blade and annulus geometry are also presented so that the experimental results can be used as a test case for 3-D turbomachinery flow analysis codes.

Strazisar, Anthony J.

Experimental Study of Bypass Transition in a Boundary Layer

A detailed investigation to compare the boundary layer transition process in a low intensity disturbance environment to that in an environment in which the disturbances are initially non-linear in amplitude was conducted using a flat plate model. The transition mechanism based on linear growth of Tollmien Schlichting (T-S) waves was associated with a freestream turbulence level of 0.3 percent; however, for a freestream turbulence intensity of 0.65 percent and higher, the bypass transition mechanism prevailed. The results of detailed measurements acquired to study and compare the two transition mechanisms indicate that there exists a critical value for the peak rms of the velocity fluctuations within the boundary layer of approximately 3 to 3.5 percent of the freestream velocity. Once the unsteadiness within the boundary layer reached this critical value, turbulent bursting initiated, regardless of the transition mechanism. The two point correlations and simultaneous time traces within the transition region illustrate the features of a turbulent burst and its effect on the surrounding flowfield.

Suder, Kenneth L.

Design and performance of controlled-diffusion stator compared with original double-circular-arc stator

The capabilities of two stators, one with controlled-diffusion (CD) blade sections and one with double-circular-arc (DCA) blade sections, were compared. A CD stator was designed and tested that had the same chord length but half the blades of the DCA stator. The same fan rotor (tip speed, 429 m/sec; pressure ratio, 1.65) was used with each stator row. The design and analysis system is briefly described. The overall stage and rotor performances with each stator are compared, as are selected blade element data. The minimum overall efficiency decrement across the stator was approximately 1 percentage point greater with the CD blade sections than with the DCA blade sections.

Gelder, Thomas F.

Design and performance of controlled-diffusion stator compared with original double-circular-arc stator

The capabilities of two stators, one with controlled-diffusion (CD) blade sections and one with double-circular-arc (DCA) blade sections, were compared. A CD stator was designed and tested that had the same chord length but half the blades of the DCA stator. The same fan rotor (tip speed, 429 m/sec; pressure ratio, 1.65) was used with each stator row. The design and analysis system is briefly described. The overall stage and rotor performances with each stator are compared, as are selected blade element data. The minimum overall efficiency decrement across the stator was approximately 1 percentage point greater with the CD balde sections than with the DCA blade sections.