Search NASA⌕ Search

Engineering topics

Suleiman, R.

Publications and source records attributed to Suleiman, R..

25 records · Page 2

Determination of the Al 27 Neutron Distribution Radius from a Parity-Violating Electron Scattering Measurement

In this paper, we report the first measurement of the parity-violating elastic electron scattering asymmetry on 27 Al. The 27 Al elastic asymmetry is $A_{\text{PV}}$ = 2.16 ± 0.11(stat) ± 0.16(syst) ppm, and was measured at $\langle Q^2\rangle$ = 0.02357 ± 0.00010 GeV$^2$, $\angleθ_{\text{lab}}$ = 7.61° ± 0.02°, and $\langle E_{\text{lab}}$ = 1.157 GeV with the Q weak apparatus at Jefferson Lab. Predictions using a simple Born approximation as well as more sophisticated distorted-wave calculations are in good agreement with this result. From this asymmetry the 27 Al neutron radius $R_n$ = 2.89 ± 0.12 fm was determined using a many-models correlation technique. The corresponding neutron skin thickness $R_n – R_p$ = –0.04 ± 0.12 fm is small, as expected for a light nucleus with a neutron excess of only 1. This result thus serves as a successful benchmark for electroweak determinations of neutron radii on heavier nuclei. A tree-level approach was used to extract the 27 Al weak radius $R_w$ = 3.00 ± 0.15 fm, and the weak skin thickness $R_{\text{wk}} – R_{\text{ch}}$ = –0.04 ± 0.15 fm. The weak form factor at this $Q^2$ is $F_{\text{wk}}$ = 0.39 ± 0.04.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inverted Geometry Ceramic Insulators in High Voltage DC Electron Guns for Accelerators

A direct current (dc) high voltage photo-emission electron gun operating at 130 kV is utilized at the Jefferson Lab (JLab) Continuous Electron Beam Accelerator Facility to generate spin-polarized electrons for nuclear physics experiments. Over the past decade, JLab has tested and implemented inverted-geometry ceramic insulators in photoguns, connecting the cathode electrode in vacuum to the high voltage power supply using commercial high voltage cables. This contribution reports on tests performed up to 375 kV dc, implementation of inverted insulators in a 300 kV dc photogun generating magnetized electron beams, and describes plans to develop a reliable insulator-cable connector for applying 500 kV dc to a future polarized beam photogun operating reliably and without field emission at 350 kV.

Hernandez-Garcia, C.↗

Superconducting RF Gun with High Current and the Capability to Generate Polarized Electron Beams

High-current low-emittance CW electron beams are indispensable for nuclear and high-energy physics fixed target and collider experiments, cooling high energy hadron beams, generating CW beams of monoenergetic X-rays (in FELs) and gamma-rays (in Compton sources). Polarization of electrons in these beams provides extra value by opening a new set of observables and frequently improving the data quality. We report on the upgrade of the unique and fully functional CW SRF 1.25 MeV SRF gun, built as part of the Coherent electron Cooling (CeC) project, which has demonstrated sustained CW operation with CsK2Sb photocathodes generating electron bunches with record-low transverse emittances and record-high bunch charge exceeding 10 nC. We propose to extend the capabilities of this system to high average current of 100 milliampere in two steps: increasing the current 30-fold at each step with the goal to demonstrate reliable long-term operation of the high-current low-emittance CW SRF guns. We also propose to test polarized GaAs photocathodes in the ultra-high vacuum (UHV) environment of the SRF gun, which has never been successfully demonstrated in RF accelerators.

43 PARTICLE ACCELERATORS↗

HIGH VOLTAGE DESIGN AND EVALUATION OF WIEN FILTERS FOR THE CEBAF 200 keV INJECTOR UPGRADE

High-energy nuclear physics experiments at the Jefferson Lab Continuous Electron Beam Accelerator Facility (CEBAF) require highly spin-polarization electron beams, produced from strained super-lattice GaAs photocathodes, activated to negative electron affinity in a photogun operating at 130 kV dc. A pair of Wien filter spin rotators in the injector defines the orientation of the electron beam polarization at the end station target. An upgrade of the CEBAF injector to better support the upcoming MOLLER experiment requires increasing the electron beam energy to 200 keV, to reduce unwanted helicity correlated intensity and position systematics and provide precise control of the polarization orientation. Our contribution describes design, fabrication and testing of the high voltage system to upgrade the Wien spin rotator to be compatible with the 200 keV beam. This required Solidworks modeling, CST and Opera electro- and magnetostatic simulations, upgrading HV vacuum feedthroughs, and assembly techniques for improving electrode alignment. The electric and magnetic fields required by the Wien condition and the successful HV characterization under vacuum conditions are also presented.

Palacios-Serrano, G.↗

Redesign of the Jefferson Lab -300 kV DC Photo-Gun for High Bunch Charge Operations

Production of high bunch charge beams for the Electron-Ion Collider (EIC) is a challenging task. High bunch charge (a few nC) electron beam studies at Jefferson Lab using an inverted insulator DC high voltage photo-gun showed evidence of space charge limitations starting at 0.3 nC, limiting the maximum delivered bunch charge to 0.7 nC for beam at -225 kV, 75 ps (FWHM) pulse width, and 1.64 mm (rms) laser spot size. The low extracted charge is due to the modest longitudinal electric field (Ez) at the photocathode leading to beam loss at the anode and downstream beam pipe. To reach the few nC high bunch charge goal, and to correct the beam deflection exerted by the non-symmetric nature of the inverted insulator photo-gun the existing photo-gun was modified. This contribution discusses the electrostatic design of the modified photo-gun obtained using CST Studio Suite’s electromagnetic field solver. Beam dynamics simulations performed using General Particle Tracer (GPT) with the resulting electrostatic field map obtained from the modified electrodes confirmed the validity of the new design.

Wijethunga, S.A.K.↗

Improving the Operational Lifetime of the CEBAF Photo-Gun by Anode Biasing

The operating lifetime of GaAs-based photocathodes in DC high voltage electron photo-guns is dominated by the ionization rate of residual beamline gas molecules. In this work, experiments were performed to quantify the improvement in photocathode charge lifetime by biasing the photo-gun anode with a positive voltage, which repels ions generated downstream of the anode. The photo-cathode charge lifetime improved by almost a factor of two when the anode was biased compared to the usual grounded configuration. Simulations were performed using the particle tracking code General Particle Tracer (GPT) with a new custom element. The simulation results showed that both the number and energy of ions play a role in the pattern of QE degradation. The experiment results and conclusions supported by GPT simulations will be presented.

Yoskowitz, J. T.↗

Measurement of the beam-normal single-spin asymmetry for elastic electron scattering from 12 C and 27 Al

We report measurements of the parity-conserving beam-normal single-spin elastic scattering asymmetries B n on 12 C and 27 Al, obtained with an electron beam polarized transverse to its momentum direction. These measurements add an additional kinematic point to a series of previous measurements of B n on 12 C and provide a first measurement on 27 Al. The experiment utilized the Q weak apparatus at Jefferson Lab with a beam energy of 1.158 GeV. The average lab scattering angle for both targets was 7.7°, and the average Q 2 for both targets was 0.02437 GeV 2 (Q = 0.1561 GeV). The asymmetries are B n = -10.68 ± 0.90 (stat) ± 0.57 (syst) ppm 12 C and B n = -12.16 ± 0.58 (stat) ± 0.62 (syst) ppm for 27 Al. The results are consistent with theoretical predictions, and are compared to existing data. When scaled by Z/A, the Q dependence of all the far-forward angle (θ < 10°) data from 1 H to 27 Al can be described by the same slope out to Q ≈ 0.35 GeV. Larger-angle data from other experiments in the same Q range are consistent with a slope about twice as steep.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗