Search NASA⌕ Search

Engineering topics

Sumnicht, Grant

Publications and source records attributed to Sumnicht, Grant.

Quantifying TOLNet Ozone Lidar Accuracy During the 2014 DISCOVER-AQ and FRAPPE Campaigns

The Tropospheric Ozone Lidar Network (TOLNet) is a unique network of lidar systems that measure high-resolution atmospheric profiles of ozone. The accurate characterization of these lidars is necessary to determine the uniformity of the network calibration. From July to August 2014, three lidars, the TROPospheric OZone (TROPOZ) lidar, the Tunable Optical Profiler for Aerosol and oZone (TOPAZ) lidar, and the Langley Mobile Ozone Lidar (LMOL), of TOLNet participated in the Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) mission and the Front Range Air Pollution and Photochemistry Experiment (FRAPPA) to measure ozone variations from the boundary layer to the top of the troposphere. This study presents the analysis of the intercomparison between the TROPOZ, TOPAZ, and LMOL lidars, along with comparisons between the lidars and other in situ ozone instruments including ozonesondes and a P-3B airborne chemiluminescence sensor. The TOLNet lidars measured vertical ozone structures with an accuracy generally better than +/-15 % within the troposphere. Larger differences occur at some individual altitudes in both the near-field and far-field range of the lidar systems, largely as expected. In terms of column average, the TOLNet lidars measured ozone with an accuracy better than +/-5 % for both the intercomparison between the lidars and between the lidars and other instruments. These results indicate that these three TOLNet lidars are suitable for use in air quality, satellite validation, and ozone modeling efforts.

TOLNet↗

Lidar Observations Revealing Transport of O3 in the Presence of a Nocturnal Low-Level Jet: Regional Implications for "Next-Day" Pollution

Remotely sensed profiles of ozone (O3) and wind are presented continuously for the first time during anocturnal low-level jet (NLLJ) event occurring after a severe O3 episode in the Baltimore-Washington D.C.(BW) urban corridor throughout 11-12 June 2015. High-resolution O3 lidar observations indicate a well mixedand polluted daytime O3 reservoir, which decayed into a contaminated nocturnal residual layer(RL) with concentrations between 70 and 100 ppbv near 1 km above the surface. Observations indicatethe onset of the NLLJ was responsible for transporting polluted O3 away from the region, while simultaneouslyaffecting the height and location of the nocturnal residual layer. High-resolution modelinganalyses and next-day (12 June) lidar, surface, and balloon-borne observations indicate the trajectory ofthe NLLJ and polluted residual layer corresponds with ''next-day'' high O3 at sites throughout thesouthern New England region (New York, Connecticut, Massachusetts). The novel O3 lidar observationsare evidence of both nocturnal advection (via high NLLJ wind fields) and entrainment of the pollutedresidual layer in the presence of the ''next-day'' convectively growing boundary layer. In the greatercontext, the novel observational suite described in this work has shown that the chemical budget in areasdownwind of major urban centers can be altered significantly overnight during transport events such asthe NLLJ.

ozone↗

Characterizing the Vertical Processes of Ozone in Colorado's Front Range Using the GSFC Ozone Dial

Although characterizing the interactions of ozone throughout the entire troposphere are important for health and climate processes, there is a lack of routine measurements of vertical profiles within the United States. In order to monitor this lower ozone more effectively, the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center TROPospheric OZone DIfferential Absorption Lidar (GSFC TROPOZDIAL) has been developed and validated within the Tropospheric Ozone Lidar Network (TOLNet). Two scientifically interesting ozone episodes are presented that were observed during the 2014 Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER AQ) campaign at Ft. Collins,Colorado.The first case study, occurring between 22-23 July 2014, indicates enhanced concentrations of ozone at Ft. Collins during nighttime hours, which was due to the complex recirculation of ozone within the foothills of the Rocky Mountain region. Although quantifying the ozone increase a loft during recirculation episodes has been historically difficult, results indicate that an increase of 20 -30 ppbv of ozone at the Ft. Collins site has been attributed to this recirculation. The second case, occurring between Aug 4-8th 2014, characterizes a dynamical exchange of ozone between the stratosphere and the troposphere. This case, along with seasonal model parameters from previous years, is used to estimate the stratospheric contribution to the Rocky Mountain region. Results suggest that a large amount of stratospheric air is residing in the troposphere in the summertime near Ft. Collins, CO. The results also indicate that warmer tropopauses are correlated with an increase in stratospheric air below the tropopause in the Rocky Mountain Region.

Sullivan, John T.↗

AROTAL Ozone and Temperature Vertical Profile Measurements from the NASA DC-8 during the SOLVE II Campaign

The AROTAL instrument (Airborne Raman Ozone Temperature and Aerosol Lidar) - a collaboration between scientists at NASA Goddard Space Flight Center, and Langley Research Center - was flown on the NASA DC-8 during the SOLVE II Campaign during January and February, 2003. The flights were flown from the Arena Arctica in Kiruna, Sweden. We report measurements of temperature and ozone profiles showing approximately a 600 ppbv loss in ozone near 17.5 km, over the time frame of the aircraft campaign. Comparisons of ozone profiles from AROTAL are made with the SAGE III instrument.

McGee, Thomas J.↗

Lidar Temperature Measurements During the SOLVE Campaign and the Absence of PSCs from Regions of Very Cold Air

NASA Goddard Space Flight Center's Airborne Raman Ozone, Temperature and Aerosol Lidar (AROTEL) measured extremely cold temperatures during all three deployments (December 1-16, 1999, January 14-29, 2000 and February 27-March 15, 2000) of the Sage III Ozone Loss and Validation Experiment (SOLVE). Temperatures were significantly below values observed in previous years with large regions regularly below 191 K and frequent temperature retrievals yielding values at or below 187 K. Temperatures well below the saturation point of type I polar stratospheric clouds (PSCs) were regularly encountered but their presence was not well correlated with PSCs observed by the NASA Langley Research Center's Aerosol Lidar co-located with AROTEL. Temperature measurements by meteorological sondes launched within areas traversed by the DC-8 showed minimum temperatures consistent in time and vertical extent with those derived from AROTEL data. Calculations to establish whether PSCs could exist at measured AROTEL temperatures and observed mixing ratios of nitric acid and water vapor showed large regions favorable to PSC formation. On several occasions measured AROTEL temperatures up to 10 K below the NAT saturation temperature were insufficient to produce PSCs even though measured values of nitric acid and water were sufficient for their formation.

Burris, John↗

Validation of Temperature Measurements from the Airborne Raman Ozone Temperature and Aerosol Lidar During SOLVE

The Airborne Raman Ozone, Temperature and Aerosol Lidar (AROTEL) participated in the recent Sage III Ozone Loss and Validation Experiment (SOLVE) by providing profiles of aerosols, polar stratospheric clouds (PSCs), ozone and temperature with high vertical and horizontal resolution. Temperatures were derived from just above the aircraft to approximately 60 kilometers geometric altitude with a reported vertical resolution of between 0.5 and 1.5 km. The horizontal footprint varied from 4 to 70 km. This paper explores the measurement uncertainties associated with the temperature retrievals and makes comparisons with independent, coincident, measurements of temperature. Measurement uncertainties range from 0.1 K to approximately 4 K depending on altitude and integration time. Comparisons between AROTEL and balloon sonde temperatures retrieved under clear sky conditions using both Rayleigh and Raman scattered data showed AROTEL approximately 1 K colder than sonde values. Comparisons between AROTEL and the Meteorological Measurement System (MMS) on NASA's ER-2 show AROTEL being from 2-3 K colder for altitudes ranging from 14 to 18 km. Temperature comparisons between AROTEL and the United Kingdom Meteorological Office's model showed differences of approximately 1 K below approximately 25 km and a very strong cold bias of approximately 12 K at altitudes between 30 and 35 km.

Burris, John↗

An Intercomparison of Lidar Ozone and Temperature Measurements From the SOLVE Mission With Predicted Model Values

Temperature profiles acquired by Goddard Space Flight Center's AROTEL lidar during the SOLVE mission onboard NASA's DC-8 are compared with predicted values from several atmospheric models (DAO, NCEP and UKMO). The variability in the differences between measured and calculated temperature fields was approximately 5 K. Retrieved temperatures within the polar vortex showed large regions that were significantly colder than predicted by the atmospheric models.

Burris, John↗

AROTEL - An Airborne Ozone, Aerosol and Temperature Lidar

The AROTEL instrument is a collaboration between scientists at NASA, Goddard Space Flight Center and NASA Langley Research Center. The instrument was designed and constructed to be flown on the NASA DC-8, and to measure vertical profiles of ozone, temperature and aerosol. The instrument transmits radiation at 308, 355, 532, and 1064 nm. Depolarization is measured at 532 nm. In addition to the transmitted wavelengths, Raman scattered signals at 332 nm and 387 nm are also collected. The instrument was installed aboard the DC-8 for the SAGE III Ozone Loss and Validation Experiment (SOLVE) which deployed from Kiruna, Sweden, during the winter of 1999-2000 to study the polar stratosphere. During this time, profile measurements of polar stratospheric clouds, ozone and temperature were made. This paper provides an instrumental overview as an introduction to several data papers to be presented in the poster sessions. In addition to samples of the measurements, examples will be given to establish the quality of the various data products.

McGee, Thomas J.↗

Arctic chemical Ozone Loss Observed by the AROTEL Instrument during the SOLVE Campaign, December 1999 - March 2000

During the winter of 1999-2000, the AROTEL instrument was deployed on the NASA DC-8 at Kiruna, Sweden for the SAGE III Ozone Loss Validation Experiment (SOLVE). Measurements of ozone, temperature and aerosols were made on 18 local science flights from December to March. Extremely low temperatures were observed throughout most of the Arctic vortex and polar stratospheric clouds were observed throughout the Arctic area during January. Significant ozone loss was measured after the sun began to rise on the vortex area in February. Ozone mixing ratios as low as 800 ppbv were observed during flights in March.

McGee, Thomas J.↗

Comparison of Temperature and Ozone Measured by the AROTEL Instrument on DC8 Overflights of Ny Aalesund during the SOLVE Mission

The AROTEL instrument, deployed on the NASA DC-8 at Kiruna, Sweden for the SAGE III Ozone Loss and Validation Experiment (SOLVE), flew over the NDSC station operated by the Alfred Wegner Institute at Ny Aalesund, Spitsbergen. AROTEL ozone and temperature measurements made during near overflights of Ny Aalesund are compared with sonde ozone and temperature, and lidar ozone measurements from the NDSC station. Nine of the seventeen science flights during the December through March measurement period overflew near Ny Aalesund. Agreement of AROTEL with the ground-based temperature and ozone values at altitudes from just above the aircraft to about 30 km gives strong confidence in using AROTEL temperature and ozone mixing ratio to study the mechanisms of ozone loss in the winter arctic polar region.

Hoegy, Walter R.↗

AROTEL Temperature Retrievals Within PSC's Using Raman Scattering

NASA Goddard Space Flight Center's Airborne Raman Ozone Temperature Lidar (AROTEL) made temperature retrievals within Polar Stratospheric Clouds (PSCs) on several flights during the SAGE III Ozone Loss and Validation Experiment (SOLVE) campaign. The location of the PSCs was confirmed using simultaneously acquired data from the NASA Langley Aerosol lidar. Retrievals were made on flight dates 991207, 991210 and 000127 from just above the aircraft to 25 kilometers geometric altitude. Raman temperature retrievals are, to first order, insensitive to Mie interference because the Raman signals are red shifted by 2331 cm(exp -1) from the initial laser wavelength. Backscattering from clouds and aerosols is consequently not observed by the detector; however, extinction does impact the measurement and limits retrievals to optically thin clouds. Comparisons between retrievals employing Rayleigh and Raman scattering show the Raman temperatures to be significantly warmer than those employing Rayleigh scattering. Uncertainties are a function of altitude: at 25 km they were approximately 3 K. Temperature profiles could not be retrieved for optically thick clouds.

Burris, John↗