Large scale energy analysis and renovation strategies for social housing in the historic city of Venice

Social houses built after the Second World War to accommodate workers and low-income families represent one of the major energy consumers and greenhouse gas emitters in the residential sector. Plans for their renovation are underway in all European countries, and the process is more complicated for Italian cities due to the lack of space and the large number of historical buildings. This study addresses this challenge by proposing a methodology to renovate a low-income district in the city of Venice using CityBES to model and evaluate energy conservation measures. CityBES is a web-based tool that allows users to employ urban building energy modeling for large-scale energy and retrofit analyses of building stocks. In the case study conducted for Venice's Santa Marta district, due to the particular context, four common energy conservation measures covering both the building envelope and heat generation boilers have been applied. The evaluation of energy-saving performances at the district level showed that the four measures together achieved 67% energy savings, an abatement in energy cost equal to 67%, and annual carbon dioxide emissions reduction of 1.1 MtCO 2 . Furthermore, the case study demonstrates a method and workflow replicable for energy retrofit analysis of building stocks in other historical districts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigation of pre-cooling as a recommended measure to improve residential buildings’ thermal resilience during heat waves

More intense heat waves are expected to occur more frequently in the twenty-first century. During severe heat waves, cooling capacity shortfall and overheating are likely to occur in residential buildings, and this will adversely affect occupant's thermal comfort and productivity. We propose a strategy of pre-cooling the house during off-peak hours to mitigate overheating during heat waves. Additionally, simulation results of a prototype single-family house show that adopting the rule-based control (RBC) of pre-cooling thermostat setpoint schedule is effective in reducing thermal discomfort, and that the efficacy of pre-cooling depends upon several building characteristics. An optimized control (OC) of the thermostat setpoint schedule was developed based on the simulation of a prototype building. A simplified yet improved RBC (IRBC) pre-cooling schedule was then extracted from the OC schedule for practical implementation at a larger scale. The effects of the RBC schedule and IRBC schedule were evaluated in the King District of Fresno, which contains 814 residential buildings. Results show that both thermostat setpoint schedules can reduce overheating effectively and that IRBC is slightly better than RBC for most buildings. The findings support the California government's recommendation on pre-cooling to mitigate overheating, which can be further improved with an optimized thermostat setpoint schedule broadcast to residents through early alert messages before a heat wave.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive cooling designs to improve heat resilience of homes in underserved and vulnerable communities

Disadvantaged communities face a growing threat to staying safe during heat waves, especially during coincident power outages. This study develops a methodology to evaluate the effectiveness of passive cooling measures (those that operate without power) to improve residential building heat resilience. Building performance is simulated for representative homes and on district scales in two disadvantaged communities in Fresno, California. Eleven passive measures are evaluated using four heat resilience metrics with and without grid power. Results show performance of the mitigation measures varies by building characteristics, surrounding environment, and power scenario. The two most effective measures were installing solar-control window films and adding roof insulation. For pre-1978 single-family homes, these two measures can reduce unmet degree-hours (UDH) indoors by 12% and 11% respectively without grid power, or 28% and 37% with grid power. Their respective UDH reductions at district scale typically range 8% — 20% and 4% — 12% without grid power, or 14% — 44% and 8% — 51% with grid power. Top floors have higher overheating risk than lower floors during extreme heat events with coincident power outages. Natural ventilation can help, reducing UDH by 21% — 26%. The methodology and findings from this study can help cities, communities, and utilities develop effective and targeted strategies to promote greater residential heat resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Italian prototype building models for urban scale building performance simulation

Urban building energy modeling (UBEM) seeks to evaluate strategies to optimize building energy use at urban scale to support a city's building energy goals. Prototype building models are usually developed to represent typical urban building characteristics of a specific use type, construction year, and climate zone, as detailed characteristics of individual buildings at urban scale are difficult to obtain. This study investigated the Italian building stock, developing 46 building prototypes, based on construction year, for residential and office buildings. The study included 16 single-family buildings, 16 multi-family buildings, and 14 office buildings. Building envelope properties and heating, ventilation, and air conditioning system characteristics were defined according to existing building energy codes and standards for climatic zone E, which covers about half the Italian municipalities. Novel contributions of this study include (1) detailed specifications of prototype building energy models for Italian residential and office buildings that can be adopted by UBEM tools, and (2) a dataset in GeoJSON format of Italian urban buildings compiled from diverse data sources and national standards. Finally, the developed prototype building specifications, the building dataset, and the workflow can be applied to create other building prototypes and to support Italian national building energy efficiency and environmental goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prototype energy models for data centers

Data centers in the United States consume about two percent of the nation’s electricity. Because heat gains from IT equipment drive cooling demand, data centers offer unique opportunities for energy savings. However, no prototype energy model for data centers is available in the suite of existing U.S. Department of Energy’s Commercial Prototype Building Models. Here we present the development of two new data center prototype models and their implementation in OpenStudio and EnergyPlus. The small-size data center model represents a computer room in a building served by computer room air conditioners (CRACs); while the large-sized model represents stand-alone data centers served by computer room air handlers (CRAHs) with a central chiller plant. For each data center model, two levels of IT equipment (ITE) load density were considered, to cover the wide range of IT power density of data centers: 40 and 100 W/ft 2 (430 and 1076 W/m 2 ) for the computer room, and 100 and 500 W/ft 2 (1076 and 5382 W/m 2 ) for the stand-alone data center. All other assumptions, such as building envelope, lighting, HVAC efficiencies and schedules, were based on the minimal requirements of ASHRAE Standard 90.1 at various vintages. We introduced a novel concept of supply and return air approach temperatures to capture the essential effects of non-uniform airflow and temperature distribution in data centers. The approach temperatures were pre-computed by computational fluid dynamics (CFD) simulations for various configurations of ITE loads and airflow containment management in data centers. A new feature was developed in EnergyPlus to implement the approach temperature method. A case study was conducted to demonstrate the use of the data center models. The two data center models cover all U.S. climate zones and can be used to evaluate energy saving measures for data centers, as well as to support development of data center energy efficiency codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Robustness of energy performance of Zero-Net-Energy (ZNE) homes

Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nexus of thermal resilience and energy efficiency in buildings: A case study of a nursing home

Extreme weather events become more frequent and severe due to climate change. Although energy efficiency technologies can influence thermal resilience of buildings, they are traditionally studied separately, and their interconnections are rarely quantified. This study developed a methodology of modeling and analysis to provide insights into the nexus of thermal resilience and energy efficiency of buildings. In this work, we conducted a case study of a real nursing home in Florida, where 12 patients died during Hurricane Irma in 2017 due to HVAC system power loss, to understand and quantify how passive and active energy efficiency measures (EEMs) can improve thermal resilience to reduce heat-exposure risk of patients. Results show that passive measures of opening windows and doors for natural ventilation, as well as miscellaneous load reduction, are very effective in eliminating the extreme dangerous occasions. However, to maintain safe conditions, active measures such as on-site power generators and thermal storage are also needed. The nursing home was further studied by changing its location to two other cities: San Francisco (mild climate) and Chicago (cold winter and hot summer). Results revealed that the EEMs' impacts on thermal resilience vary significantly by climate and building characteristics. The study also estimated the costs of EEMs to help stakeholders prioritize the measures. Passive measures that may not save energy may greatly improve thermal resilience, and thus should be considered in building design or retrofit. Findings from this study indicate energy efficiency technologies should be evaluated not only by their energy savings performance but also by their influence on a building's resilience to extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Realizing High-Accuracy Low-Cost Measurement and Verification for Deep Cost Savings (BPA Cost Share CRADA)

Developed practitioner workflows that integrate advanced M&V tools with supplementary automated routines for non-routine adjustments and for quantification of savings uncertainty to indicate rigor. Demonstrated these workflows with Seattle City Light, in collaboration with their implementers and evaluators – determine labor and time/cost savings, and uncertainty of the results obtained. Engaged the Pacific Northwest regulatory community to determine acceptance criteria for the required accuracy and reporting of advanced whole-building M&V. Documented the findings to facilitate broad industry uptake of the solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Realizing high-accuracy low-cost measurement and verification for deep cost savings (Final Project Report)

The project “Realizing high-accuracy low-cost measurement and verification for deep cost savings”, that began in Fiscal Year (FY) 2017, was funded to conduct the technical analyses, demonstration, market evaluation, and regulatory engagement necessary to realize a cost-effective high-accuracy advanced measurement and verification (M&V) method that could be applied to certain efficiency programs in the Pacific Northwest. Advanced M&V (also known as M&V 2.0), is a method that uses advanced metering infrastructure (AMI) data in combination with analytics to quantify energy efficiency savings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Assessment of occupant-behavior-based indoor air quality and its impacts on human exposure risk: A case study based on the wildfires in Northern California

he recent wildfires in California, U.S., have caused not only significant losses to human life and property, but also serious environmental and health issues. Ambient air pollution from combustion during the fires could increase indoor exposure risks to toxic gases and particles, further exacerbating respiratory conditions. This work aims at addressing existing knowledge gaps in understanding how indoor air quality is affected by outdoor air pollutants during wildfires -- by taking into account occupant behaviors (e.g., movement, operation of windows and air-conditioning) which strongly influence building performance and occupant comfort. A novel modeling framework was developed to simulate the indoor exposure risks considering the impact of occupant behaviors by integrating building energy and occupant behaviour modeling with computational fluid dynamics simulation. Occupant behaviors were found to exert significant impacts on indoor air flow patterns and pollutant concentrations, based on which, certain behaviors are recommended during wildfires. Further, the actual respiratory injury level under such outdoor conditions was predicted. The modeling framework and the findings enable a deeper understanding of the actual health impacts of wildfires, as well as informing strategies for mitigating occupant health risk during wildfires.

54 ENVIRONMENTAL SCIENCES↗

Commercial Building Energy Saver, API (CBES API) v2.0

The CBES API provides Application Programming Interface to a suite of functions to improve energy efficiency of buildings, including building energy benchmarking, preliminary retrofit analysis using a pre-simulation database DEEP, and detailed retrofit analysis using energy modeling with the EnergyPlus simulation engine. New capabilities in version 2.0 include renewable technologies (PV, storage), advanced HVAC systems, demand response measures, TDV (Time Dependent Valuation energy) metrics, as well as shading from adjacent buildings, trees or roof obstructions. The CBES API is used to power the LBNL CBES Web App. It can be used by third party developers and vendors.

Hong, Tianzhen↗

Commercial Building Energy Saver, Web App v2.0

The CBES App is a web-based toolkit for use by small businesses and building owners and operators of small and medium size commercial buildings to perform energy benchmarking and retrofit analysis for buildings. The CBES App analyzes the energy performance of user's building for pre- and post-retrofit, in conjunction with user's input data, to identify recommended retrofit measures, energy savings and economic analysis for the selected measures.

Hong, Tianzhen↗

Do energy costs really affect commercial mortgage default risk? New results and implications for energy efficiency investments [PowerPoint]

This paper presents new results on the link between energy factors and commercial mortgage default. First, we summarize results from an empirical analysis of the impact of source energy use intensity (EUI) and electricity prices on mortgage default. We used a unique data set that merges building-level energy use data from city benchmarking ordinances and financial data for commercial mortgages on the same buildings. We found that building source EUI and electricity price are statistically and economically associated with commercial mortgage defaults. Next, we present five case studies on the impact of energy use and price variations on default risk: three office buildings, a hotel, and a multi-family residential building. We use the empirical model coefficients to compute the default risk impacts due to variations in source EUI and electricity price over the course of the mortgage term. We found that variations in source EUI could raise or lower the default rates in these properties by between 5% and 40%, depending on the property type and geography. Electricity pricing has an even greater effect – roughly 60% change in default rate in the Denver area and nearly 90% in northern California. Finally, we propose an energy risk score that lenders can use to assess energy risk and inform mortgage terms. The score is being developed and piloted in collaboration with three mortgage lenders. We conclude with implications of this score as a market signal and mechanism for incentivizing energy efficiency investments through the commercial mortgage channel.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Translating climate change and heating system electrification impacts on building energy use to future greenhouse gas emissions and electric grid capacity requirements in California

Climate change and increased electrification of space and water heating in buildings can significantly affect future electricity demand and hourly demand profiles, which has implications for electric grid greenhouse gas emissions and capacity requirements. We use EnergyPlus to quantify building energy demand under historical and under several climate change projections of 32 kinds of building prototypes in 16 different climate zones of California and imposed these impacts on a year 2050 electric grid configuration by simulation in the Holistic Grid Resource Integration and Deployment (HIGRID) model. We find that climate change only prompted modest increases in grid resource capacity and negligible difference in greenhouse gas emissions since the additional electric load generally occurred during times with available renewable generation. Heating electrification, however, prompted a 30-40% reduction in greenhouse gas emissions but required significant grid resource capacity increases, due to the higher magnitude of load increases and lack of readily available renewable generation during the times when electrified heating loads occurred. Overall, this study translates climate change and electrification impacts to system-wide endpoint impacts on future electric grid configurations and highlights the complexities associated with translating building-level impacts to electric system-wide impacts.

54 ENVIRONMENTAL SCIENCES↗

NREL/OpenStudio

OpenStudio is a cross-platform collection of software tools to support whole building energy modeling using EnergyPlus and advanced daylight analysis using Radiance. This disclosure includes two OpenStudio measures: (1) data center prototype models, and (2) occupant schedule generator. The data center models cover two sizes (small computer server rooms, stand-alone large data centers) and two IT load densities (average and high).

Li, Han↗

Building simulation: Ten challenges

Buildings consume more than one-third of the world’s primary energy. Reducing energy use and greenhouse-gas emissions in the buildings sector through energy conservation and efficiency improvements constitutes a key strategy for achieving global energy and environmental goals. Building performance simulation has been increasingly used as a tool for designing, operating and retrofitting buildings to save energy and utility costs. However, opportunities remain for researchers, software developers, practitioners and policymakers to maximize the value of building performance simulation in the design and operation of low energy buildings and communities that leverage interdisciplinary approaches to integrate humans, buildings, and the power grid at a large scale. This paper presents ten challenges that highlight some of the most important issues in building performance simulation, covering the full building life cycle and a wide range of modeling scales. In conclusion, the formulation and discussion of each challenge aims to provide insights into the state-of-the-art and future research opportunities for each topic, and to inspire new questions from young researchers in this field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel Variable Refrigerant Flow (VRF) heat recovery system model: Development and validation

As one of the latest emerging HVAC technologies, the Variable Refrigerant Flow (VRF) system with heat recovery (HR) configurations has obtained extensive attention from both the academia and industry. Compared with the conventional VRF systems with heat pump (HP) configurations, VRF-HR is capable of recovering heat from cooling zones to heating zones and providing simultaneous cooling and heating operations. Moreover, this could lead to substantial energy saving potential and more flexible zonal control. In this paper, a novel model is developed to simulate the energy performance of VRF-HR systems. It adheres to a more physics-based development with the ability to simulate the refrigerant loop performance and consider the dynamics of more operational parameters, which is crucial for representing more advanced control logics. Another key feature of the model is the introduction of component-level curves for indoor units and outdoor units instead of overall performance curves for the entire system, and thus it requires much fewer user-specified performance curves as model inputs. The validation study reflects good agreements between the simulated energy use from the new VRF-HR model and the laboratory measurement data across all operational modes at sub-hourly time steps. The model has been adopted in the official release of the EnergyPlus simulation program since Version 8.6, which enables more accurate and robust assessments of VRF-HR systems to support their applications in energy retrofit of existing buildings or design of zero-net-energy buildings.