Search NASA⌕ Search

Engineering topics

Sun, Wei

Publications and source records attributed to Sun, Wei.

At least 19 records

Robust Restoration From Cyber-Physical Attacks in Active Distribution Grids With Grid-Edge IBRs

The inverter-based resources (IBRs) have enabled the integration of renewable energy at the grid edge with enhanced control capabilities to support the reliable operation of power grids. Different control frameworks, such as hierarchical or distributed architecture, have been proposed with the expansion of cyber networks for real-time monitoring and control. This evolution of critical infrastructure into cyber-physical systems also brings more vulnerabilities for the broadened attack surfaces, and significantly increases the possibility of physical system failures or outages caused by cyberattacks. Among tremendous efforts in the defense-in-depth approach, it remains challenging to provide prompt detection and accurate location of attack entry points or paths. Therefore, the prevailing restoration framework may struggle to fully consider the cyber-physical interdependence, successfully isolate the compromised cyber and physical components, and safely recover the systems without the potential risks leading to secondary outages. This paper is motivated to develop a cyber-physical restoration framework for distribution grids to recover from cyber attacks by harnessing grid-edge IBRs. The framework is first built on the operational guidelines of IBRs considering the compromised cyber layer. Then, an ambiguity set is established to represent the uncertainty of attack scenarios and their possibility levels. Next, a distributionally robust optimization model is developed to provide the optimal load restoration strategy across all scenarios. The effectiveness of the proposed model is demonstrated through various use cases on the modified IEEE 13-node and 123-node test systems. Finally, simulation results demonstrate the effectiveness and advancement of developed post-attack restoration strategies.

Cybersecurity↗

A Risk Assessment Framework for Cyber-Physical Security in Distribution Grids with Grid-Edge DERs

Integration of inverter-based distributed energy resources (DERs) is reshaping the landscape of distribution grids to fulfill the socioeconomic, environmental, and sustainability goals. Addressing the technological challenges of DER grid integration requires an adaptive communication layer for efficient DER management and control. This transition has given rise to a cyberphysical system (CPS) architecture within the distribution system, causing new vulnerabilities for cyberphysical attacks. To better address potential threats, this paper presents a comprehensive risk assessment framework for cyberphysical security in distribution grids with grid-edge DERs. The framework incorporates a detailed CPS model accounting for dynamic DER characteristics within the distribution grid. It identifies vulnerabilities in DER communication systems, models attack scenarios, and addresses communication latency crucial for inverter control timescales. Subsequently, the quantification of attack impacts employs an attack probability model including both the vulnerability and criticality of cyber components. The proposed risk assessment framework was validated through testing on the modified IEEE 13-node and 123-node test feeders.

cyberattack↗

Bayesian GAN-Based False Data Injection Attack Detection in Active Distribution Grids With DERs

Advancements in information and communication technologies have revolutionized monitoring and control capabilities within smart grids. However, it also brings new vulnerabilities to data acquisition systems and state estimation functions, which attackers can subtly tamper with the measurement data through compromising the communication network. Moreover, the high penetration of renewable energy sources with the inherited characteristics of uncertainty and variability further complicates the design of effective intrusion detection systems. In this paper, a Bayesian deep learning-based approach is developed to detect cyber attacks and maintain the security of smart grids. Our method specifically addresses the prevalent issue of imbalanced data in real power systems, which arises from the predominance of normal system operations over compromised or attacked states. Employing a novel Bayesian GAN-based technique, our approach successfully discriminates between secure and compromised measurement data, even in scenarios with significant data imbalance. Furthermore, the proposed method accommodates various practical application factors, ensuring accurate intrusion detection despite the presence of measurement noise. The feasibility and effectiveness of the proposed detection mechanism are validated by testing on IEEE 13-node and 123-node test systems. Simulation results and comparisons with literature methods demonstrate the superiority of proposed cybersecurity solutions.

Bayesian GAN↗

A Distributionally Robust Resilience Enhancement Strategy for Distribution Networks Considering Decision-Dependent Contingencies

When performing the resilience enhancement for distribution networks, there are two obstacles to reliably model the uncertain contingencies: 1) decision-dependent uncertainty (DDU) due to various line hardening decisions, and 2) distributional ambiguity due to limited outage information during extreme weather events (EWEs). Here, to address these two challenges, this paper develops scenario-wise decision-dependent ambiguity sets (SWDD-ASs), where the DDU and distributional ambiguity inherent in EWE-induced contingencies are simultaneously captured for each possible EWE scenario. Then, a two-stage tri-level decision-dependent distributionally robust resilient enhancement (DD-DRRE) model is formulated, whose outputs include the optimal line hardening, distributed generation (DG) allocation, and proactive network reconfiguration strategy under the worst-case distributions in SWDD-ASs. Subsequently, the DD-DRRE model is equivalently recast to a mixed-integer linear programming (MILP)-based master problem and multiple scenario-wise subproblems, facilitating the adoption of a customized column-and-constraint generation (C&CG) algorithm. Finally, case studies demonstrate a remarkable improvement in the out-of-sample performance of our model, compared to its prevailing stochastic and robust counterparts. Moreover, the potential values of incorporating the ambiguity and distributional information are quantitatively estimated, providing a useful reference for planners with different budgets and risk-aversion levels.

decision-dependent uncertainty↗

Small-Signal Angle Stability-Oriented False Data Injection Cyber-Attacks on Power Systems

The small-signal angle stability (SSAS) of a power system is determined by the property of operation points. The widely applied false data injection (FDI) cyber-attack, however, is able to stealthily mislead the optimal power flow (OPF) and thus compromise operation points, leading to damages to the SSAS margin. Here, to provide insights for cyber defenders, this paper proposes and investigates a stealthy SSAS-oriented FDI cyber-attack focusing on two attacking purposes, i.e., the SSAS margin and operation cost, with higher priority on the former one. First, this paper establishes a novel bi-level model with an implicit SSAS constraint based on a structure preserving model to compromise operation points. Then, for the SSAS interarea mode in a typical two-area system, this paper formulates closed-form expressions of how the SSAS margin and operation cost behave with respect to stealthy injections. By comparison, for the SSAS local mode in general power systems, this paper proposes a moving target cyber-attack-based hierarchical solution algorithm. Simulation results on a two-area system, a Kundur 11 bus system, and a modified IEEE 14 bus system demonstrate the significant damaging effects of the proposed SSAS-oriented FDI cyber-attack and the conflict between the two attacking purposes.

Benders decomposition↗

A Voltage Inference Framework for Real-Time Observability in Active Distribution Grids

Active distribution grids are gaining traction to meet the growing environmental, socio-economic, and sustainability targets. Various advanced smart grid technologies facilitate the integration of Distributed Energy Resources (DERs) by supporting the bi-directional power flow. The limited observability of distribution grids, primarily related to their location at the very edge of power system infrastructure, brings challenges to optimal grid management. Moreover, only a limited number of measurements at regular intervals are usually available. This paper presents a novel inference framework, referred to as “Voltage Inference”, to overcome the observability issues. The proposed framework employs a prediction step based on the Multivariate Taylor series approximation, followed by a corrector step that minimizes the estimation error to infer the otherwise unknown voltages from the available measurements. Furthermore, numerical results on the IEEE 13-bus test feeder validate the accuracy and computational performance of the proposed framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrokinetic comparison of CaF 2 and AgCl from a MDS perspective

CaF 2 has limited electrokinetic sensitivity to fluoride ions in solution and the positive CaF 2 surface charge is not reversed at high fluoride ion concentration. Similar insensitivity of surface charge to high fluoride ion concentration has been observed for other alkali and alkaline earth fluoride salts. On the contrary, chloride ions act as potential determining ions for AgCl and reverse the surface charge, as expected. FTIR-IRS results indicate that the AgCl/water interface has a water structure-breaking tendency, whereas the CaF 2 /water interface has a structure-making tendency. Here, it is speculated that the strong hydrogen bonding between fluoride ions and water prevents the accommodation of excess fluoride ions at surface lattice sites of fluorite, and therefore explains the low sensitivity of the fluorite surface charge sign and magnitude to fluoride ion concentration. However, this speculation has not been examined at the molecular level and is evaluated by molecular dynamics simulations (MDS) in the research presented in this paper. Higher hydrogen bond density at the CaF 2 mineral/water interface confirms that the water structure has stronger hydrogen bonding at both the CaF 2 mineral surface and with the F - ion in solution. In this way, the interaction of the F - ion with the CaF 2 surface is inhibited.

36 MATERIALS SCIENCE↗

Glueballs at physical pion mass

Glueballs are investigated through gluonic operators on two $ N_f=2+1 $ RBC/UKQCD gauge ensembles at the physical pion mass. The statistical errors of glueball correlation functions are considerably reduced through the cluster decomposition error reduction (CDER) method. The Bethe-Salpeter wave functions are obtained for the scalar, tensor, and pseudoscalar glueballs by using spatially extended glueball operators defined through the gauge potential $ A_\mu(x) $ in the Coulomb gauge. These wave functions exhibit similar features of non-relativistic two-gluon systems and are used to optimize the signals of the related correlation functions at the early time regions, where the ground state masses are extracted. These masses are close to those from the quenched approximation and indicate the possible existence of glueballs at the physical point. The resonance feature of glueballs and the mixing with conventional mesons and multi-hadron systems should be considered in a more systematic lattice study.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Cost and Benefit of Enhancing Cybersecurity for Hybrid AC/DC Grids

As critical interfaces of AC grids and DC grids inside a hybrid AC/DC grid, the voltage-sourced-converter (VSC) has been demonstrated to be vulnerable to false data injection (FDI) cyber-attacks. As a result, the cyber-attack-induced AC grid frequency deviations and DC grid voltage deviations threaten the secure operation. Here, to enhance cybersecurity in a not only feasible but also cost-effective manner, this paper proposes a cost-benefit-based cyber-defense strategy for a hybrid AC/DC grid. First, this paper establishes a spatial-temporal dual cyber-attack evaluation model, in which the cyber-attack-induced frequency and voltage deviations are modelled in both a spatially and temporally dual manner. Then, the proposed cost-benefit-based cyber-defense strategy is modelled as a VSC commitment problem to achieve the trade-off between maximizing the cyber-defense benefits and minimizing the cyber-defense costs. The VSC commitment problem is then mathematically convexified into a mixed-integer second-order cone programming (MISOCP) problem, which could be efficiently solved in an event-triggered manner against unfolding cyber-attack events. Simulation results on a test hybrid AC/DC grid verified the feasibility and the cost-effectiveness of the proposed cyber-defense strategy.

cost-benefit analysis↗

Dissecting Tensor Cores via Microbenchmarks: Latency, Throughput and Numeric Behaviors

Tensor Cores have been an important unit to accelerate Fused Matrix Multiplication Accumulation (MMA) in all NVIDIA GPUs since Volta Architecture. To program Tensor Cores, users have to use either legacy wmma APIs or current mma APIs. Legacy wmma APIs are more easy-to-use but can only exploit limited features and power of Tensor Cores. Specifically, wmma APIs support fewer operand shapes and can not leverage the new sparse matrix multiplication feature of the newest Ampere Tensor Cores. However, the performance of current programming interface has not been well explored. Furthermore, the computation numeric behaviors of low-precision floating points (TF32, BF16, and FP16) supported by the newest Ampere Tensor Cores are also mysterious. In this paper, we explore the throughput and latency of current programming APIs. Further, we intuitively study the numeric behaviors of Tensor Cores MMA and profile the intermediate operations including multiplication, addition of inner product, and accumulation. All codes used in this work can be found in https://github.com/sunlex0717/DissectingTensorCores.

97 MATHEMATICS AND COMPUTING↗

Analysis of the Selective Flotation of Elemental Gold from Pyrite Using Diisobutyl Monothiophosphate

The gold contained in copper ores is an important resource for the gold industry. In some cases, elemental gold is present and can be recovered by selective flotation. It has been reported that the gold grade and recovery can be increased, without sacrificing the copper recovery, by replacing AERO 3477 (diisobutyl dithiophosphate (DTP)) with AERO 7249 (mixture of diisobutyl monothiophosphate (MTP) and diisobutyl dithiophosphate (DTP)) as the main collector. The fundamental understanding of the improvement in selectivity with the addition of MTP in the flotation of elemental gold from pyrite is limited and is the subject of this paper. In this regard, the hydrophobicity and selectivity of DTP and MTP in the flotation of pyrite and gold are compared and discussed. Density functional theory (DFT) was used to examine the electron density, reactivity, highest occupied molecular orbital (HOMO), and lowest unoccupied molecular orbital (LUMO) of the MTP and DTP collectors. The interaction energies for the adsorption of MTP and DTP from fresh pyrite, oxidized pyrite and gold surfaces were calculated and discussed with respect to the experimental results reported in the literature. Molecular dynamics simulation (MDS) was used to examine the adsorption state of MTP and DTP on the pyrite (100) and Au (111) surfaces.

58 GEOSCIENCES↗

Molecular dynamics simulation of seeded crystal growth in glass

The mechanism of non-congruent growth of a crystal from glass has been sought using molecular dynamics simulations. Specifically, as a model of this process, the growth of a lithium niobate (LiNbO 3 ) crystal seed sandwiched between two lithium niobosilicate (LNS) glass slabs has been simulated as a function of time and temperature. The growth of pre-existing crystal is strongly affected by the orientation of crystal seed, temperature, and the SiO 2 concentration in the surrounding LNS glass matrix. The orientation of LiNbO 3 seed surface that has inherently larger interplanar distance results in a relatively slower crystal growth. The addition of SiO 2 to LNS system significantly decreases the crystal growth, which primarily occurs in the region devoid of Si. The suppressive effect of SiO 2 on growth rate can be traced to the existence of defect complex comprising of Si substituted at the Nb site and a nearby Nb vacancy.

36 MATERIALS SCIENCE↗

Effect of iron redox ratio on the structures of boroaluminosilicate glasses

Iron oxide is commonly found in natural or industrial glass compositions and can exist as ferrous (Fe 2+ ) or ferric (Fe 3+ ) species, with their ratios depending on glass composition, temperature, pressure and the redox reactions during the glass forming process. The iron redox ratio plays an important role on silicate glass structures and consequently various properties. This work aims to study the effect of iron oxide, and particularly the iron redox ratio, on the structures of borosilicate and boroaluminosilicate glasses using molecular dynamics simulations with newly developed iron potential parameters that are compatible with the borosilicate potentials. The results provide detailed cation coordination states of both iron species and the effect of redox ratio on boron coordination and other structural features. Particularly, competition for charge compensating modifier cations (such as Na + ) among the fourfold-coordinated cations such as B 3+ , Al 3+ , and Fe 3+ is investigated by calculating the cation–cation pair distribution functions and coordination preferential ratios. The results show that the trivalent ferric ions, with a shorter Fe–O bond distance and better defined first coordiation shell with mainly four-fold coordination, act as a glass former whereas the divalent ferrous ions mainly play the role of glass modifier. The ferrous/ferric ratio (Fe 2+ /Fe 3+ ) was found to affect the glass chemistry and hence glass properties by regulating the amount of four-coordinated boron, the fraction of non-briding oxygen and other features. Finally, the results are compared with available experimental data to gain insights of the complex structures and charge compensation schemes of the glass system.

36 MATERIALS SCIENCE↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen and Battery Storage Technologies for Low-Cost Energy Decarbonization in Distribution Networks

Deep energy decarbonization cannot be achieved without high penetration of renewables. At higher renewable energy penetrations, the variability and intermittent nature of solar photovoltaic (PV) electricity can cause ramping issues with existing fossil fuel generation, requiring longer term energy storage to increase the reliability of grid operation. Here, a proton exchange membrane electrolyzer can produce H 2 and serves as a utility controllable load. The produced H 2 can then be stored and converted back into electricity, or mixed with natural gas, or used as transportation fuel, or chemical feedstock. This paper considers the perspective of the distribution system operator that operates the distributed energy resources on a standard IEEE 33-node distribution network considering the technical and physical constraints with the goal of minimizing total investment and operation cost. Different case studies, at very high PV penetrations are considered to show the challenges and path to net-zero emission energy production using H 2 energy. Sensitivity of utility PV costs and electrolyzer capital costs on producing H 2 at $\$1$ /kg are presented showing that the distribution network could produce 100% renewable electricity and H 2 could be produced at a cost of $\$1$ /kg by 2050 with conservative cost estimates and by 2030 with accelerated cost declines.

25 ENERGY STORAGE↗