Search NASA⌕ Search

Engineering topics

Sun, Wenqing

Publications and source records attributed to Sun, Wenqing.

Using [{sup 18}F]Fluorothymidine Imaged With Positron Emission Tomography to Quantify and Reduce Hematologic Toxicity Due to Chemoradiation Therapy for Pelvic Cancer Patients

Purpose: The purpose of the present prospective clinical trial was to determine the efficacy of [{sup 18}F]fluorothymidine (FLT)-identified active bone marrow sparing for pelvic cancer patients by correlating the FLT uptake change during and after chemoradiation therapy with hematologic toxicity. Methods and Materials: Simulation FLT positron emission tomography (PET) images were used to spare pelvic bone marrow using intensity modulated radiation therapy (IMRT BMS) for 32 patients with pelvic cancer. FLT PET scans taken during chemoradiation therapy after 1 and 2 weeks and 30 days and 1 year after completion of chemoradiation therapy were used to evaluate the acute and chronic dose response of pelvic bone marrow. Complete blood counts were recorded at each imaging point to correlate the FLT uptake change with systemic hematologic toxicity. Results: IMRT BMS plans significantly reduced the dose to the pelvic regions identified with FLT uptake compared with control IMRT plans (P<.001, paired t test). Radiation doses of 4 Gy caused an ∼50% decrease in FLT uptake in the pelvic bone marrow after either 1 or 2 weeks of chemoradiation therapy. Additionally, subjects with more FLT-identified bone marrow exposed to ≥4 Gy after 1 week developed grade 2 leukopenia sooner than subjects with less marrow exposed to ≥4 Gy (P<.05, Cox regression analysis). Apparent bone marrow recovery at 30 days after therapy was not maintained 1 year after chemotherapy. The FLT uptake in the pelvic bone marrow regions that received >35 Gy was 18.8% ± 1.8% greater at 30 days after therapy than at 1 year after therapy. The white blood cell, platelet, lymphocyte, and neutrophil counts at 1 year after therapy were all lower than the pretherapy levels (P<.05, paired t test). Conclusions: IMRT BMS plans reduced the dose to FLT-identified pelvic bone marrow for pelvic cancer patients. However, reducing hematologic toxicity is challenging owing to the acute radiation sensitivity (∼4 Gy) and chronic suppression of activity in bone marrow receiving radiation doses >35 Gy, as measured by the FLT uptake change correlated with the complete blood cell counts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Change of Maximum Standardized Uptake Value Slope in Dynamic Triphasic [{sup 18}F]-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Distinguishes Malignancy From Postradiation Inflammation in Head-and-Neck Squamous Cell Carcinoma: A Prospective Trial

Purpose: To evaluate dynamic [{sup 18}F]-fluorodeoxyglucose (FDG) uptake methodology as a post–radiation therapy (RT) response assessment tool, potentially enabling accurate tumor and therapy-related inflammation differentiation, improving the posttherapy value of FDG–positron emission tomography/computed tomography (FDG-PET/CT). Methods and Materials: We prospectively enrolled head-and-neck squamous cell carcinoma patients who completed RT, with scheduled 3-month post-RT FDG-PET/CT. Patients underwent our standard whole-body PET/CT scan at 90 minutes, with the addition of head-and-neck PET/CT scans at 60 and 120 minutes. Maximum standardized uptake values (SUV{sub max}) of regions of interest were measured at 60, 90, and 120 minutes. The SUV{sub max} slope between 60 and 120 minutes and change of SUV{sub max} slope before and after 90 minutes were calculated. Data were analyzed by primary site and nodal site disease status using the Cox regression model and Wilcoxon rank sum test. Outcomes were based on pathologic and clinical follow-up. Results: A total of 84 patients were enrolled, with 79 primary and 43 nodal evaluable sites. Twenty-eight sites were interpreted as positive or equivocal (18 primary, 8 nodal, 2 distant) on 3-month 90-minute FDG-PET/CT. Median follow-up was 13.3 months. All measured SUV endpoints predicted recurrence. Change of SUV{sub max} slope after 90 minutes more accurately identified nonrecurrence in positive or equivocal sites than our current standard of SUV{sub max} ≥2.5 (P=.02). Conclusions: The positive predictive value of post-RT FDG-PET/CT may significantly improve using novel second derivative analysis of dynamic triphasic FDG-PET/CT SUV{sub max} slope, accurately distinguishing tumor from inflammation on positive and equivocal scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Radiation-Induced Malignancy With Heterotopic Ossification Prophylaxis: A Case–Control Analysis

Purpose: To determine the risk of radiation-induced malignancy after prophylactic treatment for heterotopic ossification (HO). Methods and Materials: A matched case–control study was conducted within a population-based cohort of 3489 patients treated either for acetabular fractures with acetabular open reduction internal fixation or who underwent total hip arthroplasty from 1990 to 2009. Record-linkage techniques identified patients who were diagnosed with a malignancy from our state health registry. Patients with a prior history of malignancy were excluded from the cohort. For each documented case of cancer, 2 controls were selected by stratified random sampling from the cohort that did not develop a malignancy. Matching factors were sex, age at time of hip treatment, and duration of follow-up. Results: A total of 243 patients were diagnosed with a malignancy after hip treatment. Five patients were excluded owing to inadequate follow-up time in the corresponding control cohort. A cohort of 238 cases (control, 476 patients) was included. Mean follow-up was 10 years, 12 years in the control group. In the cancer cohort, 4% of patients had radiation therapy (RT), compared with 7% in the control group. Of the 9 patients diagnosed with cancer after RT, none occurred within the field. The mean latency period was 5.9 years in the patients who received RT and 6.6 years in the patients who did not. Median (range) age at time of cancer diagnosis in patients who received RT was 62 (43-75) years, compared with 70 (32-92) years in the non-RT patients. An ad hoc analysis was subsequently performed in all 2749 patients who were not matched and found neither an increased incidence of malignancy nor a difference in distribution of type of malignancy. Conclusion: We were unable to demonstrate an increased risk of malignancy in patients who were treated with RT for HO prophylaxis compared with those who were not.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid emission angle selection for rotating-shield brachytherapy

Purpose: The authors present a rapid emission angle selection (REAS) method that enables the efficient selection of the azimuthal shield angle for rotating shield brachytherapy (RSBT). The REAS method produces a Pareto curve from which a potential RSBT user can select a treatment plan that balances the tradeoff between delivery time and tumor dose conformity. Methods: Two cervical cancer patients were considered as test cases for the REAS method. The RSBT source considered was a Xoft Axxent{sup TM} electronic brachytherapy source, partially shielded with 0.5 mm of tungsten, which traveled inside a tandem intrauterine applicator. Three anchor RSBT plans were generated for each case using dose-volume optimization, with azimuthal shield emission angles of 90 Degree-Sign , 180 Degree-Sign , and 270 Degree-Sign . The REAS method converts the anchor plans to treatment plans for all possible emission angles by combining neighboring beamlets to form beamlets for larger emission angles. Treatment plans based on exhaustive dose-volume optimization (ERVO) and exhaustive surface optimization (ERSO) were also generated for both cases. Uniform dwell-time scaling was applied to all plans such that that high-risk clinical target volume D{sub 90} was maximized without violating the D{sub 2cc} tolerances of the rectum, bladder, and sigmoid colon. Results: By choosing three azimuthal emission angles out of 32 potential angles, the REAS method performs about 10 times faster than the ERVO method. By setting D{sub 90} to 85-100 Gy{sub 10}, the delivery times used by REAS generated plans are 21.0% and 19.5% less than exhaustive surface optimized plans used by the two clinical cases. By setting the delivery time budget to 5-25 and 10-30 min/fx, respectively, for two the cases, the D{sub 90} contributions for REAS are improved by 5.8% and 5.1% compared to the ERSO plans. The ranges used in this comparison were selected in order to keep both D{sub 90} and the delivery time within acceptable limits. Conclusions: The REAS method enables efficient RSBT treatment planning and delivery and provides treatment plans with comparable quality to those generated by exhaustive replanning with dose-volume optimization.

60 APPLIED LIFE SCIENCES↗