Cation-disordered rocksalt-type high-entropy cathodes for Li-ion batteries
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Sun, Y..
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e. comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range ${5 \times 10^{-3}}\,\mathrm{eV}^2 \lesssim \varDelta m^2_{41} \lesssim {3 \times 10^{-1}}\,\mathrm{eV}^2$ for mixing angles down to $\sin ^2 2\theta _{14} \gtrsim {0.02}$. No significant disappearance additionally to the conventional disappearance related to $\theta _{13}$ is observed and correspondingly exclusion bounds on the sterile mixing parameter $\theta _{14}$ as a function of $\varDelta m^2_{41}$ are obtained.
This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.
Collective rotational bands were observed for the first time in neutron-rich odd–odd 142 La by means of γ-γ-γ and γ-γ-γ-γ coincidence measurements of prompt fission γ rays from 252 Cf using multi-detector array Gammasphere. Similarity between the yrast band of 142 La and those of neighboring 144 La, 144 Ce was found and interpreted as quasiparticle excitations. Here, PES calculations suggested triaxial deformation for the ground state of 142La. Considerable triaxial and near zero octupole deformations were deduced for the yrast band of 142 La by the TRS model calculations. The band-crossing observed in the yrast band of 142 La was interpreted to be caused by alignment of the (h 11/2 ) 2 proton pair, and the crossing frequency was best reproduced by the TRS calculations taking into account triaxial deformations. In contrast to the interpretations for the band crossing of 142 La, alignments of the (i 13/2 ) 2 neutron pair were found to be responsible for the band-crossing of the yrast band in the neighboring even-N 143 La, and triaxial degree of freedom was found to play a more significant role than octupole deformations in the nucleus, although its β 3 values deduced are large.
A graded buffer Bragg reflector (GBBR) is a bifunctional device component that provides the reflection of a distributed Bragg reflector and the adjustable lattice constant of a compositionally graded buffer. Prior work showed that these properties can be combined with low threading dislocation density and high reflectivity. Here, we design and demonstrate complex GBBRs for specific metamorphic solar cell applications. We design buffers that provide (1) high reflectivity over a narrow bandwidth, for quantum well solar cells, (2) reflectivity over a wide bandwidth, for optically thin solar cells, and (3) low sidelobe reflection, for multijunction devices that demand low out-of-band reflection. Apodized and triple GBBRs are demonstrated, and transparency is always considered, requiring designs with carefully engineered material combinations. A GBBR with a reflection of 99% is demonstrated, as well as a triple GBBR that has over 80% reflection for 100?nm of the spectrum around 800?nm. We also analyze potential deviations in a baseline GBBR from that of a perfect DBR using transmission electron microscopy to analyze imperfections in the material and modeling to analyze the impact of imperfect refractive index data for lattice-mismatched AlGaInAs. Minimal crosshatch roughness and unintentional thickness variation occur throughout the buffer, which likely influences reflection slightly. Small deviations between the calculated AlGaInAs and utilized AlGaAs refractive index exist, giving methods for future GBBR improvement. While the GBBR designs are intended for metamorphic solar cells, the broad and high reflection may also be useful for other optoelectronic devices such as light-emitting diodes or lasers.
A θ 13 oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of θ 13 and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data collected in both detectors with at least one reactor in operation. The oscillation results are enhanced by the use of 24.06 days (12.74 days) of reactor-off data in the far (near) detector. The analysis considers the ${\overline{\nu}}_e$ interactions up to a visible energy of 8.5 MeV, using the events at higher energies to build a cosmogenic background model considering fast-neutrons interactions and 9 Li decays. The background-model-independent determination of the mixing angle yields sin 2 (2 θ 13 ) = 0.094 ± 0.017, being the best-fit total background rates fully consistent with the cosmogenic background model. A second oscillation analysis is also performed constraining the total background rates to the cosmogenic background estimates. While the central value is not significantly modified due to the consistency between the reactor-off data and the background estimates, the addition of the background model reduces the uncertainty on θ 13 to 0.015. Along with the oscillation results, the normalization of the anti-neutrino rate is measured with a precision of 0.86%, reducing the 1.43% uncertainty associated to the expectation.
Neutron-rich nuclei 162,164 Eu were produced by bombarding a proton beam on a 238 U target at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory and mass separating the 162,164 Eu products. New level schemes and new γ-ray transitions of the daughters 162,164 Gd were identified from β-decay spectroscopy studies. Additionally, half-lives of the 162,164 Eu were remeasured to clarify the previous ambiguous results. Two quasiparticle band structures were built and compared with neighboring nuclei. The β and γ bands were extended in 162 Gd and a γ band was extended in 164 Gd. Half-lives of the isomeric states at (6 - ) 1449 keV in 162 Gd and (4 - ) 1096 keV in 164 Gd were measured to be 99(3) μs and 0.56(3) μs, respectively. Projected shell model calculations were performed and found to be in good agreement with all of the experimental data.
Explore the source record for details and available documents.
Background: Neutron-rich nuclei in the mass region around A = 160 have been and will continue to be of interest for the study of nuclear structure because of the rapid onset of deformation between 88 and 90 neutrons. The observation of detailed changes in nuclear structures within this mass region has provided and will continue to provide insight into the nuclear force. Purpose: Investigations of γ rays emitted following Eu 163 β -decay to Gd 163 have been performed for evaluation of the nuclear structure of Gd 163 . Method: Data were collected at the LeRIBSS station of the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory with an array of four Clover HPGe detectors for γ -rays and two plastic scintillators for β detection. The γ rays were identified as belonging to Gd 163 via mass selection and γ – γ – β , x-ray- γ , or γ – γ coincidences. Results: In total 107 new γ -ray transitions were observed in Gd 163 from 53 newly identified levels. Conclusions: We report the structure of Gd 163 has been identified for the first time. This structure has been evaluated in comparison to projected shell model, and potential energy surface calculations with good agreement.
Neutrinos were assumed to be massless particles until the discovery of the neutrino oscillation process. This phenomenon indicates that the neutrinos have non-zero masses and the mass eigenstates (nu(1), nu(2), nu(3)) are mixtures of their flavour eigenstates (nu(e), nu(mu), nu(tau)). The oscillations between different flavour eigenstates are described by three mixing angles (theta(12), theta(23), theta(13)), two differences of the squared neutrino masses of the nu(2)/nu(1) and nu(3)/nu(1) pairs and a charge conjugation parity symmetry violating phase delta(CP). The Double Chooz experiment, located near the Chooz Electricite de France reactors, measures the oscillation parameter theta(13) using reactor neutrinos. Here, the Double Chooz collaboration reports the measurement of the mixing angle theta(13) with the new total neutron capture detection technique from the full data set, yielding sin(2)(2 theta(13)) = 0.105 +/- 0.014. This measurement exploits the multidetector configuration, the isoflux baseline and data recorded when the reactors were switched off. In addition to the neutrino mixing angle measurement, Double Chooz provides a precise measurement of the reactor neutrino flux, given by the mean cross-section per fission <sigma(f)& rang; = (5.71 +/- 0.06) x 10(-43) cm(2) per fission, and reports an empirical model of the distortion in the reactor neutrino spectrum. The Double Chooz collaboration reports the neutrino oscillation parameter theta(13) from a measurement of the disappearance of reactor anti-electron neutrinos with the total neutron capture technique.
Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.
Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.
In this work, we report observations of an intense, multi-band, sub-THz and THz radiation extracted from a similar to 2-3 MeV electron beam with a flat transverse profile propagating in an oversized rectangular waveguide placed into a 3.25 mm gap of a planar undulator having 1.3 cm period and similar to 20 cm length. Radiation outcoupling is accomplished using a horn antenna and a miniature permanent in-vacuum magnet separating the mm-sub-mm-waves and electron beam. A table-top experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet producing microbunches of a sub-mm length. Total radiated energy of a sub-millijoule per a microsecond radio frequency macropulse is demonstrated with flux more than ten micro-Joules per centimeter squared. With 1 THz filter the energy measured is about 1 microjoule and flux of a few micro-Joules per centimeter squared.
Abstract not provided.
Not provided.