Fourier waveform analyzer
Real-time Fourier analysis is provided by "bucket brigade' charge-transfer shift register. Device is small, inexpensive integrated circuit which does analog-to-digital-to-analog conversion, data processing, and time delay.
Engineering topics
Publications and source records attributed to Sutton, J. F..
Real-time Fourier analysis is provided by "bucket brigade' charge-transfer shift register. Device is small, inexpensive integrated circuit which does analog-to-digital-to-analog conversion, data processing, and time delay.
The design techniques, circuit components, fabrication techniques, and past experience used in successful high-voltage power supplies for spacecraft flight systems are described. A discussion of the basic physics of electrical discharges in gases is included and a design rationale for the prevention of electrical discharges is provided. Also included are typical examples of proven spacecraft high-voltage power supplies with typical specifications for design, fabrication, and testing.
Transposer operates entirely in analog domain. Input analog signal is serially loaded into analog register at rate determined by voltage-controlled oscillator. At same time, signal is serially unloaded from other register at expanded time rate determined by divider output feeding through switch.
Explore the source record for details and available documents.
The relative cross sections for simultaneous ionization and excitation of helium by 200 eV electrons into the 4S, 4P, 4D and 4F levels have been measured via a fast delayed coincidence technique. Results are in poor agreement with Born approximation calculations for simultaneous ionization and excitation of helium, the 4P component being larger than expected.
The relative cross sections for simultaneous ionization and excitation of helium by 200-eV electrons into the 4 2s and 4 2p states were measured via a fast delayed coincidence technique. Results show good agreement with the relative cross sections for single electron excitation of helium and hydrogen. An application of the results of the measurement to the development of ultraviolet intensity standard is suggested. This technique involves the use of known branching ratios, a visible light flux reference, and the measured relative cross sections.
A fast electron gun with subnanosecond rise and decay times and 100 mA peak beam current has been developed for delayed coincidence studies of atomic decays. The gun is fabricated from an inexpensive tetrode nuvistor, only slightly modified. The electron gun system has been successfully used in a delayed concidence study of fast decays of ionized helium.
The fast decay time of a 3900-A spectral component of an electron-beam excited P-15 phosphor has been measured using a delayed coincidence technique. The result, 1.04 nsec plus or minus nearly 2%, is in good agreement with previous estimates.
The fast luminescent decay of the MV-50 GaAs doped Si light-emitting diode has been studied. This diode is found to provide a fast, inexpensive, bright, and convenient light source for the calibration of fast optical timing systems. A simple passive electronic module is described that allows driving the light source directly by a laboratory pulse generator.
Fast luminescent decay of silicon light-emitting diode
During the development of a delayed coincidence apparatus for the study of atomic decays, the need arose for a bright, fast, and inexpensive light source with known decay characteristics. A sample of P-15 phosphor was obtained for use as a calibration light source. A short pulse duration was employed to preferentially excite the short lifetime components relative to the longer-lived ones. The computer analysis revealed that the raw MCA decay curve data could be described well by a sum of three exponentials with decay times of about 88 nsec, about 6.5 nsec, and 1.04 + or - 2%.
A fast electron gun with subanosecond rise- and decay-times and 100 ma. peak beam current has been developed for delayed coincidence studies of atomic decays. The gun is fabricated from an inexpensive tetrode Nuvistor, involving only slight modification.
System suppresses spurious sinusoidal responses of any sinusoidally driven amplifier showing time-dependent phase shift versus frequency function. System is applicable to any sinusoidally driven amplifier. Technique eliminates, or reduces, unwanted spurious vibrations during tests to determine dynamic frequency responses of mechanical systems.
Control techniques for simultaneous three degree of freedom hydraulic vibration system