Search NASA⌕ Search

Engineering topics

Suzuki, M

Publications and source records attributed to Suzuki, M.

At least 19 records

SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.

60 APPLIED LIFE SCIENCES↗

Hard X-ray Fourier Transform Holography Using a Reference Scatterer Fabricated by Electron-Beam-Assisted Chemical-Vapor Deposition

We present a fabrication method for a reference source that is efficient when used for lensless Fourier transform holography. This method produces a reference source that yields high spatial resolution and enhanced signal-to-noise ratio in a Fourier-transformed real-space image, and is particularly useful for Fourier transform holography experiments in the hard x-ray region.

07 ISOTOPE AND RADIATION SOURCES↗

Improvement of sensitivity in high-resolution Rutherford backscattering spectroscopy

The sensitivity (limit of detection) of high-resolution Rutherford backscattering spectroscopy (HRBS) is mainly determined by the background noise of the spectrometer. There are two major origins of the background noise in HRBS, one is the stray ions scattered from the inner wall of the vacuum chamber of the spectrometer and the other is the dark noise of the microchannel plate (MCP) detector which is commonly used as a focal plane detector of the spectrometer in HRBS. In order to reject the stray ions, several barriers are installed inside the spectrometer and a thin Mylar foil is mounted in front of the detector. The dark noise of the MCP detector is rejected by the coincidence measurement with the secondary electrons emitted from the Mylar foil upon the ion passage. After these improvements, the background noise is reduced by a factor of 200 at a maximum. The detection limit can be improved down to 10 ppm for As in Si at a measurement time of 1 h under ideal conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MAXI Nova Alert System and the Latest Scientific Results

MAXI, Monitor of All-sky X-ray Image, is the first astronomical telescope onboard the ISS. One of the main goals of our mission is to discover new transient objects by scanning more than 95% of the sky every {approx}92 min with two types of X-ray cameras, Gas Slit Camera (GSC) and Solid-state Slit Camera (SSC). We have developed a completely new data analysis system, a nova alert system, to find transient objects and send alerts to the world as soon as possible. Here we describe the current status of the system, and transient objects discovered with the system.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray photoelectron spectroscopy study of polyimide thin films with Ar cluster ion depth profiling

X-ray photoelectron spectroscopy depth profiling of polyimide thin films on silicon substrates using an Ar cluster ion beam results in an extremely low degradation of the polyimide chemistry. In the range from 2.5 to 20 kV, a lower cluster ion energy produces a lower sputter induced damage to the polymer and results in an improved polyimide to silicon interface width. The sputtering rates of the polyimide are found to increase exponentially with an increase in the Ar cluster ion energy.

36 MATERIALS SCIENCE↗

Approaches to analyzing insulators with Auger Electron Spectroscopy: Update and Overview

This paper provides an updated overview, intended to be of practical value to analysts, of methods that can be applied to minimize or control the buildup of near surface electrical charge during electron induced Auger electron spectroscopy (AES). Although well developed methods can be highly effective, dealing with insulating or ungrounded samples for which high spatial resolution is needed remains a challenge. Examples of the application of methods involving low energy ion sources and sample thinning using a focused ion beam that can allow high resolution measurements on a variety of samples are highlighted. The physical bases of newer and traditional methods are simply described along with strengths and limitations of the methods. Summary tables indicate which methods apply to almost any spectrometer, which require special instrumental capabilities, and those that require special sample preparation or mounting.

36 MATERIALS SCIENCE↗

Radiobiological study by using laser-driven proton beams

Particle acceleration driven by high-intensity laser systems is widely attracting interest as a potential alternative to conventional ion acceleration, including ion accelerator applications to tumor therapy. Recent works have shown that a high intensity laser pulse can produce single proton bunches of a high current and a short pulse duration. This unique feature of laser-ion acceleration can lead to progress in the development of novel ion sources. However, there has been no experimental study of the biological effects of laser-driven ion beams. We describe in this report the first demonstrated irradiation effect of laser-accelerated protons on human lung cancer cells. In-vitro A549 cells are irradiated with a proton dose of 20 Gy, resulting in a distinct formation of gamma-H2AX foci as an indicator of DNA double-strand breaks. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. The laser-driven ion beam is apotential excitation source for time-resolved determination of hydroxyl (OH) radical yield, which will explore relationship between the fundamental chemical reactions of radiation effects and consequent biological processes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NAA TECHNIQUE FOR CLINICAL INVESTIGATION OF MICE IMMUNIZED WITH BOTHROP VENOM

In the present study Neutron Activation Analysis (NAA) technique was used to determine sodium concentration in whole blood of mice immunized with Bothrops venom. With this value it was possible to perform clinical investigation in this animal model using whole blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

New probes of GRB prompt emission properties using wide-band spectroscopy by Suzaku Wide-band All-sky Monitor

Although the afterglow observations in HETE-2 and Swift era have revealed a lot of afterglow properties of gamma-ray bursts (GRBs), we still have poor understanding of the prompt gamma-ray emission, such as the emission mechanism of the prompt emission and differences between short and long duration GRBs. We have observed many prompt emission of GRBs by Suzaku Wide-band All-sky Monitor in wide energy range of 50-5000 keV, with very large effective area of 400 cm{sup 2} even at 1 MeV. Furthermore, a combination of the Suzaku/WAM and Swift data provides us not only wider energy range of 15-5000 keV but also redshift information even for some short GRBs. Thanks to these information, we can firstly investigate an intrinsic correlation for short GRBs like E{sub peak}-L{sub iso} relation, and we can derive the same type of relation for time-resolved spectra of long GRBs in finer time-scale with higher statistics than ever before. These results could be used to discuss the differences between short and long GRBs, and our time-resolved E{sub peak}-L{sub iso} relation also could be used as both more appropriate redshift indicator and new probe of the fireball dynamics.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of laser-accelerated protons to the demonstration of DNA double-strand breaks in human cancer cells

We report the demonstrated irradiation effect of laser-accelerated protons on human cancer cells. In vitro (living) A549 cells are irradiated with quasimonoenergetic proton bunches of 0.8-2.4 MeV with a single bunch duration of 15 ns. Irradiation with the proton dose of 20 Gy results in a distinct formation of {gamma}-H2AX foci as an indicator of DNA double-strand breaks generated in the cancer cells. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. Unique high-current and short-bunch features make laser-driven proton bunches an excitation source for time-resolved determination of radical yields.

61 RADIATION PROTECTION AND DOSIMETRY↗

Extended high-order harmonics from laser-produced Cd and Cr plasmas

We observed the extended harmonic spectra generated in the Cd and Cr plasmas. The mechanism of harmonic extension was attributed to the harmonic generation in doubly charged particles and the influence of broadband ionic resonances in the range of 20-25 nm. The extension of harmonic cutoff up to the 73rd (Cd) and 83rd (Cr) orders was achieved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absence of Complete Finite-Larmor-Radius Stabilization in Extended MHD

The dominant finite-Larmour-radius (FLR) stabilization effects on interchange instability can be retained by taking into account the ion gyroviscosity or the generalized Ohm's law in an extended MHD model. However, recent simulations and theoretical calculations indicate that complete FLR stabilization of the interchange mode may not be attainable by ion gyroviscosity or the two-fluid effect alone in the framework of extended MHD. For a class of plasma equilibria in certain finite-{beta} or nonisentropic regimes, the critical wave number for complete FLR stabilization tends toward infinity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three dimensional image construction and spectrum extraction from two dimensional elemental mapping in Auger electron spectroscopy

Three dimensional Auger elemental distributions have been constructed from the combination of high spatial resolution, two dimensional Auger maps obtained at multiple sputter depths. These three dimensional elemental distributions have been used to compare the interfacial regions for two kinds of silicon on insulator wafers. It is clearly seen that silicon oxide is formed as an island structure for the SIMOX specimen, whereas the UNIBOND specimen has a featureless structure at the Si/SiO{sub 2} interface. Linear least squares fitting from several two dimensional maps obtained at different energies have been used to produce energy dispersive spectra from specific regions of high spatial resolution Auger maps. This technique was used to examine the interface region exposed from sputter craters through a silicon dioxide layer on a silicon substrate and through a Ni silicide film on a silicon substrate. The Si LVV spectra for the elemental silicon, oxide, and silicide components extracted from the multiple energy two dimensional maps can be used to map the chemical components in the interfacial regions.

36 MATERIALS SCIENCE↗

Status of GRB Observations with the Suzaku Wideband All-sky Monitor

The Wide-band All-sky Monitor (WAM) is a made up of the large lateral BGO shield of the Hard X-ray Detector (HXD) onboard Suzaku. Its large geometrical area of 800 cm{sup 2} per side, the large stopping power for the hard X-rays and the wide-field of view make the WAM an ideal detector for gamma-ray bursts (GRBs) observations in the energy range of 50-5000 keV. In fact, the WAM has observed 288 GRBs confirmed by other satellites, till the end of May 2007.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of A New Background Reduction Method for WXM/HETE-2 and Its Application for Bright GRB Spectra

HETE-2 detected gamma-ray bursts (GRBs) since its launch on 9 October 2000. For spectral analyses using data of WXM on-board HETE-2, background spectra are conventionally obtained with time regions before and/or after prompt emission. In some cases, the background spectra change during the prompt emission and/or the downlink trouble causes a loss of data around the prompt emission. If this is the case, the problem seems to lie in the fact that the conventional method cannot obtain correct background spectra. To make more appropriate background spectra, we develop a new analysis method using mask patterns of the WXM. The background spectra are estimated with shaded regions by the WXM mask pattern using the prompt emission data. Our new method might obtain a reliable result for a spectrum of GRB 030329. In this paper, we introduce our new analysis method and show a preliminary spectral result.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low- and high-order nonlinear optical properties of Au, Pt, Pd, and Ru nanoparticles

We investigate third- and higher-order nonlinear optical processes in Au, Pt, Pd, and Ru nanoparticles. We measured the nonlinear refractive indices and nonlinear absorption coefficients of the suspensions of these nanoparticles using the 792 nm femtosecond and picosecond pulses. The highest values of these parameters were observed in the case of Au nanoparticles (-8x10{sup -14} m{sup 2} W{sup -1} and 1.7x10{sup -10} m W{sup -1}), when the 210 ps pulses were used as a probe radiation. The high-order harmonic generation was studied during the propagation of the 120 fs pulses through the plasmas produced on the surfaces containing the nanoparticles. The highest harmonic cutoff (33rd order) was observed in the case of gold nanoparticle-contained plasma. These results were compared with the harmonics generating from the plasma produced on the surfaces of the bulk materials of the same origin. A two- to sixfold enhancement of harmonic yield was observed in the case of nanoparticle-contained plumes with regard to the bulk materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low- and high-order nonlinear optical properties of BaTiO{sub 3} and SrTiO{sub 3} nanoparticles

We present the studies of the third- and higher-order nonlinear optical processes in barium titanate (BaTiO{sub 3}) and strontium titanate (SrTiO{sub 3}) nanoparticles. We measured the nonlinear refractive indices and nonlinear absorption coefficients of the BaTiO{sub 3} and SrTiO{sub 3} nanoparticles dissolved in ethylene glycol using the 790 nm fs and ps pulses. The high-order harmonic generation up to the 39th order was achieved in the BaTiO{sub 3} and SrTiO{sub 3} nanoparticles-contained plumes when the femtosecond radiation propagated through the preformed plasma. The 1x10{sup -6} and 4x10{sup -6} high-order harmonic efficiencies at the plateau region were achieved in the cases of the BaTiO{sub 3} and SrTiO{sub 3} nanoparticles-contained plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗