Search NASA⌕ Search

Engineering topics

Svoboda, R.

Publications and source records attributed to Svoboda, R..

At least 19 records

The BUTTON-30 detector at Boulby

The BUTTON-30 detector is a 30-tonne technology demonstrator designed to evaluate the potential of hybrid event detection, simultaneously exploiting both Cherenkov and scintillation light to detect particles produced in neutrino interactions. The detector is installed at a depth of 1.1 km in the Boulby Underground Laboratory allowing to test the performance of this new technology underground in a low background environment. This paper describes the design and construction of the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First light from beam neutrinos on an LAPPD in ANNIE

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is both a physics experiment and a technology testbed for next-generation light-based neutrino detection. In this paper, we report the first demonstration of a fully integrated Large Area Picosecond Photodetector (LAPPD) operating in a running neutrino beam experiment. Particular focus is given to the design, commissioning, and successful deployment of the Packaged ANNIE LAPPD (PAL), a waterproof, self-triggering module incorporating fast waveform digitization and precision timing synchronized to the ANNIE detector subsystems. We identify beam-correlated LAPPD data frames consistent with charged-current neutrino interactions observed in multiple detector subsystems, establishing the first detection of neutrino-induced Cherenkov light with an LAPPD. These results validate the system-level performance of LAPPDs under realistic experimental conditions — including long-term stability, timing synchronization, and event matching with conventional PMT and muon detector systems — marking a critical step toward their deployment in future large-scale neutrino and particle detectors.

Cherenkov detectors↗

Design and development of optical modules for the BUTTON-30 detector

BUTTON-30 is a neutrino detector demonstrator located in the STFC Boulby underground facility in the north-east of England. The main goal of the project is to deploy and test the performance of the gadolinium-loaded water-based liquid scintillator for neutrino detection in an underground environment. This will pave the way for a future large-volume neutrino observatory that can also perform remote monitoring of nuclear reactors for nonproliferation. This paper describes the design and construction of the watertight optical modules of the experiment.

COMSOL simulations↗

First Light from Beam Neutrinos on an LAPPD in ANNIE,

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) probes the physics of neutrino-nucleus interactions in a gadolinium-loaded water (Gd-water) target while serving as a flexible testbed for advanced next-generation optical neutrino detection technologies. These advanced technologies include novel detection media (particularly Gd-water and hybrid Cherenkov-scintillation through water-based liquid scintillator) and novel photosensors. In this paper we demonstrate the first implementation of a fully-integrated setup for Large Area Picosecond PhotoDetectors (LAPPDs) in a neutrino experiment. Details are presented regarding the design, commissioning, and deployment of an LAPPD and the supporting systems. We also present the first neutrino interactions ever observed with an LAPPD.

FOS: Physical sciences↗

Deployment of Water-based Liquid Scintillator in the Accelerator Neutrino Neutron Interaction Experiment

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton water Cherenkov neutrino detector installed on the Booster Neutrino Beam (BNB) at Fermilab. Its main physics goals are to perform a measurement of the neutron yield from neutrino-nucleus interactions, as well as a measurement of the charged-current cross section of muon neutrinos. An equally important focus is the research and development of new detector technologies and target media. Specifically, water-based liquid scintillator (WbLS) is of interest as a novel detector medium, as it allows for the simultaneous detection of Cherenkov light and scintillation. This paper presents the deployment of a 366 L WbLS vessel in ANNIE in March 2023 and the subsequent detection of both Cherenkov light and scintillation from the WbLS. Finally, this proof-of-concept allows for the future development of reconstruction and particle identification algorithms in ANNIE, as well as dedicated analyses within the WbLS volume, such as the search for neutral-current events and the hadronic scintillation component.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the neutron cross section on argon between 95 and 720 MeV

We report an extended measurement of the neutron cross section on argon in the energy range of 95-720 MeV. The measurement was obtained with a 4.3-hour exposure of the Mini-CAPTAIN detector to the WNR/LANSCE beam at LANL. Compared to an earlier analysis of the same data, this extended analysis includes a reassessment of systematic uncertainties, in particular related to unused wires in the upstream part of the detector. Using this information we doubled the fiducial volume in the experiment and increased the statistics by a factor of 2.4. Here we also shifted the analysis from energy bins to time-of-flight bins. This change reduced the overall considered energy range, but improved the understanding of the energy spectrum of incoming neutrons in each bin. Overall, the new measurements are extracted from a fit to the attenuation of the neutron flux in five time-of-flight regions: 140ns-180ns, 120ns-140ns, 112ns-120ns, 104ns-112ns, 96ns-104ns. The final cross sections are given for the flux-averaged energy in each time-of-flight bin with statistical and systematic (syst) uncertainties: σ(146 MeV) = 0.60 $^{+0.14}_{-0.14}$ ±0.08(syst) b, σ(236 MeV) = 0.72 $^{+0.10}_{-0.10}$ ± 0.04(syst) b, σ(319 MeV) = 0.80 $^{+0.13}_{-0.12}$ ±0.040(syst) b, σ(404 MeV) = 0.74 $^{+0.14}_{-0.09}$ ±0.04(syst) b, σ(543 MeV) = 0.74 $^{±0.09}_{-0.09}$ ± 0.04(syst) b.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence of Antineutrinos from Distant Reactors Using Pure Water at SNO+

The SNO+ Collaboration reports the first evidence of reactor antineutrinos in a Cherenkov detector. The nearest nuclear reactors are located 240 km away in Ontario, Canada. Here, this analysis uses events with energies lower than in any previous analysis with a large water Cherenkov detector. Two analytical methods are used to distinguish reactor antineutrinos from background events in 190 days of data and yield consistent evidence for antineutrinos with a combined significance of 3.5 σ.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Eos: conceptual design for a demonstrator of hybrid optical detector technology

Eos is a technology demonstrator, designed to explore the capabilities of hybrid event detection technology, leveraging both Cherenkov and scintillation light simultaneously. With a fiducial mass of four tons, Eos is designed to operate in a high-precision regime, with sufficient size to utilize time-of-flight information for full event reconstruction, flexibility to demonstrate a range of cutting edge technologies, and simplicity of design to facilitate potential future deployment at alternative sites. Results from Eos can inform the design of future neutrino detectors for both fundamental physics and nonproliferation applications. This paper describes the conceptual design and potential applications of the Eos

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Mini-CAPTAIN liquid argon time projection chamber

This manuscript describes the commissioning of the Mini-CAPTAIN liquid argon detector in a neutron beam at the Los Alamos Neutron Science Center (LANSCE), which led to a first measurement of high-energy neutron interactions in argon. The Mini-CAPTAIN detector consists of a Time Projection Chamber (TPC) with an accompanying photomultiplier tube (PMT) array sealed inside a liquid-argon-filled cryostat. The liquid argon is constantly purified and recirculated in a closed-loop cycle during operation. The specifications and assembly of the detector subsystems and an overview of their performance in a neutron beam are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of Beam-Correlated Background Neutrons from the Fermilab Booster Neutrino Beam in ANNIE Phase-I

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) aims to make a unique measurement of neutron yield from neutrino-nucleus interactions and to perform R&D for the next generation of water-based neutrino detectors. In this paper, we characterize beam-induced neutron backgrounds in the experimental hall at Fermi National Accelerator Laboratory. It is shown that the background levels are sufficiently low to allow the next stage of the experiment to proceed. These measurements are relevant to other Booster Neutrino Beam (BNB) [1] experiments located adjacent to ANNIE Hall, where dirt neutrons and sky-shine could present similar backgrounds.

Particle identification methods↗

Measurement of the neutron capture cross section on argon

The use of argon as a detection and shielding medium for neutrino and dark matter experiments has made a precise knowledge of the cross section for neutron capture on argon an important design and operational parameter. While previous measurements were averaged over thermal spectra and have significant disagreements, a differential measurement has been performed using a Time-Of-Flight neutron beam and a ~4π gamma spectrometer. Here, a fit to the differential cross section from 0.015-0.15 eV, assuming a 1/v energy dependence, yields σ 2200 = 673 ± 26 (stat.) ± 59 (sys.) mb.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute calibration of the DANCE thermal neutron beam using sodium activation

The calculation of the neutron capture cross section as a function of energy in the thermal range requires a precise knowledge of the absolute neutron flux. In this paper a method of calibrating a thermal neutron beam using the controlled activation of sodium is described. Here, the method is applied to the FP-14 Time Of Flight neutron beam line at the Los Alamos Neutron Science Center to calibrate the beam to an uncertainty level of ±5 %.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗