Search NASA⌕ Search

Engineering topics

Swanson, Michael

Publications and source records attributed to Swanson, Michael.

Performance of hydrophobic physical solvents for pre-combustion CO 2 capture at a pilot scale coal gasification facility

Here, in this paper, we present the first pilot plant data for hydrophobic physical solvents for CO 2 and H 2 S removal from coal-derived H 2 -rich syngas. Four physical solvents were tested under pre-combustion CO 2 capture conditions at bench scale and pilot plant scale: one baseline hydrophilic solvent and three hydrophobic solvents. The solvents were: (1) polyethylene-glycol-dimethyl ether (PEGDME), a hydrophilic solvent analog for the commercial process Selexol, (2) tributyl- phosphate (TBP), a commercially available hydrophobic solvent, (3) polyethylene glycol-poly(dimethylsiloxane) (PEG-PDMS-3), and (4) diethyl sebacate (CASSH-1), a novel, computationally screened hydrophobic solvent developed by the National Energy Technology Laboratory (NETL). All solvents were studied under pure gas (CO 2 /N 2 /H 2 /CH 4 ) equilibrium conditions at NETL followed by pilot plant testing with syngas at the University of North Dakota Energy & Environmental Research Center (UND EERC). Long term performance of CASSH-1 and PEDGME was then assessed with results compared to process simulation predictions. Within experimental uncertainties, all solvents showed comparable CO 2 absorption performance at above room temperature operation while the hydrophobic solvents had limited water uptake and low vapor pressure, which alleviates concerns related to corrosion, water absorption, and solvent loss to evaporation. These results indicate low viscosity, low vapor pressure hydrophobic solvents are a promising option for lower cost CO 2 capture from high pressure syngas applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Subtask 2.5 – Syngas Testing of NETL's Advanced Precombustion CO2 Capture Solvent

U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) on-site researchers have been examining and developing a novel solvent for precombustion capture that has the potential for improved performance and lower costs compared to Selexol™ and Rectisol®. In Subtask 2.5, the Energy & Environmental Research Center (EERC) conducted actual comparison tests on actual coal-derived syngas of a PEGDME (polyethylene glycol dimethyl ether) Selexol-type solvent and three other solvents provided by NETL. One was a new hybrid PEG–PDMS (poly[dimethylsiloxane]) solvent engineered by NETL. In addition, two commercially available chemicals that are projected to have good CO2 capture abilities were also selected for testing on actual coal-derived syngas. These tests were conducted in the EERC high-pressure fluid-bed gasifier (HPFBG) system utilizing an existing gas-sweetening absorption system (GSAS) to test the solvents. The four solvents tested were Solvent 1 – AGR II from Coastal Chemical Co., LLC, NETL Solvent 2 – XG-3229 Bis(methoxytriethyleneoxypropyl)hexamethyltrisiloxane, as manufactured by Gelast, Inc.; Solvent 3 – CASSH-1 (diethyl sebacate), procured from Sigma Aldrich; and Solvent 4 – TBP (tributyl phosphate), purchased from ThermoFisher Scientific. The solvents were all tested at a consistent syngas flow and composition at approximately 50 bar to make direct comparisons easier; two solvent flow rates which would bracket 90% CO2 capture; and, temperatures of 10°, 25°, 40°, and 55°C to determine the effects of temperature on CO2 uptake and CO2 to H2 selectivity. Figure E-1 shows the results for CO2 uptake and selectivity for the various solvents. These data show that the CO2 uptake for the Selexol-type solvent for the PEG-PDMS-3 and CASHH-1 solvents at higher operating temperatures around 40°C was better than the Selexol-type solvent was able to achieve at the lower operating temperature of 10°C. Selectivity of CO2 over H2 was at least as good as Selexol for the PEG-PDMS-3 solvent and even better than Selexol for the CASSH-1 solvent. The TBP solvent also displayed good CO2 uptake; however, CO2/H2 selectivity was worse than for the Selexol-type solvent. Operation of precombustion CO2 solvents at temperatures above ambient can provide a 2% process efficiency improvement along with a significant capital cost reduction since refrigeration and solvent dehydration equipment is not required. The excellent results from these tests warrant further longer-duration testing with one or both superior NETL-provided solvents to determine if longer-term exposure to any coal-derived syngas trace species may have an adverse impact on solvent performance. This project was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233.

01 COAL, LIGNITE, AND PEAT↗

Long-Term Demonstration of Hydrogen Production from Coal at Elevated Temperatures: Year 6 - Activity 1.12 - Development of a National Center for Hydrogen Technology

The Energy & Environmental Research Center (EERC) has continued the work of the National Center for Hydrogen Technology® (NCHT®) Program Year 6 Task 1.12 project to expose hydrogen separation membranes to coal-derived syngas. In this follow-on project, the EERC has exposed two membranes to coal-derived syngas produced in the pilot-scale transport reactor development unit (TRDU). Western Research Institute (WRI), with funding from the State of Wyoming Clean Coal Technology Program and the North Dakota Industrial Commission, contracted with the EERC to conduct testing of WRI’s coal-upgrading/gasification technology for subbituminous and lignite coals in the EERC’s TRDU. This gasifier fires nominally 200–500 lb/hour of fuel and is the pilot-scale version of the full-scale gasifier currently being constructed in Kemper County, Mississippi. A slipstream of the syngas was used to demonstrate warm-gas cleanup and hydrogen separation using membrane technology. Two membranes were exposed to coal-derived syngas, and the impact of coal-derived impurities was evaluated. This report summarizes the performance of WRI’s patent-pending coal-upgrading/ gasification technology in the EERC’s TRDU and presents the results of the warm-gas cleanup and hydrogen separation tests. Overall, the WRI coal-upgrading/gasification technology was shown to produce a syngas significantly lower in CO 2 content and significantly higher in CO content than syngas produced from the raw fuels. Warm-gas cleanup technologies were shown to be capable of reducing sulfur in the syngas to 1 ppm. Each of the membranes tested was able to produce at least 2 lb/day of hydrogen from coal-derived syngas.

01 COAL, LIGNITE, AND PEAT↗

Material Testing of Coated Alloys in a Syngas Combustion Environment Year 6 - Activity 1.13 - Development of a National Center for Hydrogen Technology

Modifications were made to the inlet of the existing Energy & Environmental Research Center (EERC) thermal oxidizer to accommodate side-by-side coupon holders for exposure testing. Two 5-day tests with over 200 hours of total exposure time were completed. The first week of testing was conducted in enriched air-blown mode, with coupon temperatures ranging from 128° to 272°F. Carbonyl sampling was conducted, but it was discovered after the fact that the methodology used was producing very low recoveries of iron and nickel carbonyl. Therefore, the data generated during this week of testing were not considered accurate. The second week of testing was conducted in oxygen-blown mode, with coupon temperatures ranging from 220° to 265°F. Two improved methods were used to measure carbonyl concentration during this week of testing. These methods produced results closer to equilibrium calculations. Since both weeks of testing mostly produced a product gas with approximately 15%–18% carbon monoxide, it was felt that actual carbonyl concentrations for Week 1 should be very similar to those measured during Week 2. The revised carbonyl sampling methodology used during the second week of testing greatly improved the recovery of iron and nickel carbonyl in the sample. Even though the sampling results obtained from the first week were inaccurate, the results from the second week can be used as an estimate for the periods during which the gasifier was operating under similar conditions and producing similar product gas compositions. Specifically, Test Periods 2 and 3 from the first week were similar to the conditions run during the second week. For a product gas containing roughly 15%–18% CO and a coupon temperature of approximately 220°–270°F, the nickel carbonyl concentration should be about 0.05–0.1 ppm and the iron carbonyl concentration should be about 0.1–0.4 ppm. After each week of testing the coupons were recovered from the coupon holder, weighed, and shipped back to Siemens for analysis.

42 ENGINEERING↗

Subtask 2.8 - Control of Trace Elements in Gasification Systems

Detailed investigations were carried out to investigate the removal of mercury using a variety of substrates at elevated temperature under reducing conditions. Sorbents tested mainly comprised 6A, 7A, 1B, 2B, and metals from the periodic table. The new high-surface halogen-treated carbon sorbents performed exceptionally well on the bench scale at relatively high temperatures (400 C). The new sorbents could be incorporated into a gas cleanup technology for fuel gas, where the gas is cooled to medium temperatures. Other work in this task focused on halogen-containing sorbents prepared on a carbon support. Similar sorbents had been previously found to be superior for mercury in flue gas. All granular sorbents were conducted in fixed beds heated at 350 and 400 C with 10 vol% hydrogen in a nitrogen stream containing 34.8 {mu}g/m{sup 3} of Hg{sup 0}.

08 HYDROGEN↗

JV Task - 129 Advanced Conversion Test - Bulgarian Lignite

The objectives of this Energy & Environmental Research Center (EERC) project were to evaluate Bulgarian lignite performance under both fluid-bed combustion and gasification conditions and provide a recommendation as to which technology would be the most technically feasible for the particular feedstock and also identify any potential operating issues (such as bed agglomeration, etc.) that may limit the applicability of a potential coal conversion technology. Gasification tests were run at the EERC in the 100-400-kg/hr transport reactor development unit (TRDU) on a 50-tonne sample of lignite supplied by the Bulgarian Lignite Power Project. The quality of the test sample was inferior to any coal previously tested in this unit, containing 50% ash at 26.7% moisture and having a higher heating value of 5043 kJ/kg after partial drying in preparation for testing. The tentative conclusion reached on the basis of tests in the TRDU is that oxygen-blown gasification of this high-ash Bulgarian lignite sample using the Kellogg, Brown, and Root (KBR) transport gasifier technology would not provide a syngas suitable for directly firing a gas turbine. After correcting for test conditions specific to the pilot-scale TRDU, including an unavoidably high heat loss and nitrogen dilution by transport air, the best-case heating value for oxygen-blown operation was estimated to be 3316 kJ/m{sup 3} for a commercial KRB transport gasifier. This heating value is about 80% of the minimum required for firing a gas turbine. Removing 50% of the carbon dioxide from the syngas would increase the heating value to 4583 kJ/m{sup 3}, i.e., to about 110% of the minimum requirement, and 95% removal would provide a heating value of 7080 kJ/m{sup 3}. Supplemental firing of natural gas would also allow the integrated gasification combined cycle (IGCC) technology to be utilized without having to remove CO{sub 2}. If removal of all nitrogen from the input gas streams such as the coal transport air were achieved, a heating value very close to that needed to fire a gas turbine would be achieved; however, some operational issues associated with utilizing recycled syngas or carbon dioxide as the transport gas would also have to be resolved. Use of a coal with a quality similar to the core samples provided earlier in the test program would also improve the gasifier performance. Low cold-gas efficiencies on the order of 20% calculated for oxygen-blown tests resulted in part from specific difficulties experienced in trying to operate the pilot-scale TRDU on this very high-ash lignite. These low levels of efficiency are not believed to be representative of what could be achieved in a commercial KRB transport gasifier. Combustion tests were also performed in the EERC's circulating fluidized-bed combustor (CFBC) to evaluate this alternative technology for use of this fuel. It was demonstrated that this fuel does have sufficient heating value to sustain combustion, even without coal drying; however, it will be challenging to economically extract sufficient energy for the generation of steam for electrical generation. The boiler efficiency for the dried coal was 73.5% at 85% sulfur capture (21.4% moisture) compared to 55.3% at 85% sulfur capture (40% moisture). Improved boiler efficiencies for this coal will be possible operating a system more specifically designed to maximize heat extraction from the ash streams for this high-ash fuel. Drying of the coal to approximately 25% moisture probably would be recommended for either power system. Fuel moisture also has a large impact on fuel feedability. Pressurized gasifiers generally like drier fuels than systems operating at ambient pressures. The commercially recommended feedstock moisture for a pressurized transport reactor gasifier is 25% moisture. Maximum moisture content for a CFB system could be approximately 40% moisture as has been demonstrated on the Alstom CFB operating on Mississippi lignite. A preliminary economic evaluation for CO{sub 2} was performed on the alternatives of (1) precombustion separation of CO{sub 2} in an IGCC using the KBR transport gasifier and (2) postcombustion CO{sub 2} capture using a CFBC. It appears that the capture of CO{sub 2} from the high-pressure IGCC precombustion system would be less costly than from the low-pressure postcombustion CFBC system by a factor of 1.5, although the cost difference is not directly comparable because of the model input being limited to a higher coal quality than the Bulgarian lignite. While the decision to pursue precombustion removal of carbon dioxide has been technically proven with the Rectisol{reg_sign} and Selexol{trademark} processes, General Electric and Siemens have not sold any gas turbine systems running on the high-hydrogen syngas. They have successfully demonstrated a gas turbine on syngases containing up to 95% hydrogen. The technological hurdles should not be too difficult given this experience in the gas turbine industry.

01 COAL, LIGNITE, AND PEAT↗

Subtask 4.4 - North Dakota Lignite Fuel Upgrading

This project will add the capability for the Energy & Environmental Research Center (EERC) to conduct Fischer-Tropsch (FT) catalyst testing at a scale consistent with the benchscale continuous fluid-bed reactor. This capability will enable various vendors to test their FT catalysts on actual coal-derived syngas. The project goals were to also develop some EERC expertise with issues associated with FT liquid production. A study by Dr. Calvin Bartholmew at Brigham Young University (BYU) is further apparent that it is possible to build a single reactor (rather than multiple reactors of different sizes) consisting of three 1-inch-diameter, 10 foot-long tubes to accommodate the anticipated range of catalytic activities and process conditions. However, this single reactor should ideally be designed to operate over a significant range of recycle ratio (e.g., 1-10), temperature (25-400 C), pressure (10-25 bar), flow rate (1-6 scfm), and cooling duty (0.2-1.5 kW). It should have the flexibility of flowing gas to one, two, or three tubes. Based on the recommended design specifications provided by BYU while staying within the approved budget, the EERC decided to build a two fixed-bed reactor system with the capability to add a third reactor at a later time. This system was constructed to be modular and sized such that it can fit into the area around the EERC continuous fluid-bed reactor or also be located in explosion-rated areas such as the gasification tower next to the EERC pilot-scale transport reactor or in the National Center for Hydrogen Technology building high-bay area.

01 COAL, LIGNITE, AND PEAT↗

Subtask 7.4 - Power River Basin Subbituminous Coal-Biomass Cogasification Testing in a Transport Reactor

The U.S. Department of Energy (DOE) National Energy Technology Laboratory Office of Coal and Environmental Systems has as its mission to develop advanced gasification-based technologies for affordable, efficient, zero-emission power generation. These advanced power systems, which are expected to produce near-zero pollutants, are an integral part of DOE's Vision 21 Program. DOE has also been developing advanced gasification systems that lower the capital and operating costs of producing syngas for chemical production. A transport reactor has shown potential to be a low-cost syngas producer compared to other gasification systems since its high-throughput-per-unit cross-sectional area reduces capital costs. This work directly supports the Power Systems Development Facility utilizing the Kellogg Brown and Root transport reactor located at the Southern Company Services Wilsonville, Alabama, site. Over 3600 hours of operation on 17 different coals ranging from bituminous to lignite along with a petroleum coke has been completed to date in the pilot-scale transport reactor development unit (TRDU) at the Energy & Environmental Research Center (EERC). The EERC has established an extensive database on the operation of these various fuels in both air- and oxygen-blown modes utilizing a pilot-scale transport reactor gasifier. This database has been useful in determining the effectiveness of design changes on an advanced transport reactor gasifier and for determining the performance of various feedstocks in a transport reactor. The effects of different fuel types on both gasifier performance and the operation of the hot-gas filter system have been determined. It has been demonstrated that corrected fuel gas heating values ranging from 90 to 130 Btu/scf have been achieved in air-blown mode, while heating values up to 230 Btu/scf on a dry basis have been achieved in oxygen-blown mode. Carbon conversions up to 90% have also been obtained and are highly dependent on the oxygen-coal ratio. Higher-reactivity (low-rank) coals appear to perform better in a transport reactor than the less reactive bituminous coals. Factors that affect TRDU product gas quality appear to be coal type, temperature, and oxygen/fuel ratios. During this series of tests, a previously tested baseline Powder River Basin (PRB) subbituminous coal from the Peabody Energy North Antelope Rochelle Mine near Gillette, Wyoming was mixed with 20 wt% biomass. Two types of biomass were used - wood waste and switchgrass. Gas and particulate sampling at several locations in the riser provided information on coal devolatilization and cracking chemistry as a function of residence time, transport gas, and mode of operation. The goal of these tests was to compare the operating data and sample chemistry of the coal-biomass mixture to the PRB coal, with a focus on Fischer-Tropsch coal-to-liquid production in oxygen-blown mode. Data are to be provided to DOE to determine kinetic rates of devolatilization and tar cracking.

01 COAL, LIGNITE, AND PEAT↗