Pulse shape measurements for neutron/gamma discrimination using the TOFPET2 ASIC

Many highly pixelated organic scintillator detection systems would benefit from independent readout of each scintillator pixel. Recent advances in Silicon Photomultiplier (SiPM) technology makes this goal feasible, however the data acquisition from potentially hundreds or thousands of channels requires a low-cost and compact solution. For pixelated neutron detection with organic scintillators, the capability to distinguish between neutron and gamma interactions using Pulse Shape Discrimination (PSD) is required along with pulse charge and time of arrival. The TOFPET2 ASIC from PETsys Electronics is a 64-channel readout chip providing pulse time and charge integration measurements from SiPMs, and is specifically designed for time-of-flight positron-emission tomography. Using an 8 × 8 array of 6 mm × 6 mm J-series SiPMs from SensL/OnSemi (ArrayJ-60035-64P-PCB), we have studied the energy and PSD performance of the TOFPET2 ASIC using a 4 × 4 array of 6 mm × 6 mm × 30 mm trans -Stilbene crystals from Inrad Optics and a custom SiPM routing board from PETsys Electronics. In conclusion, using a time-over-threshold method, we measure a maximum PSD figure-of-merit of approximately 1.2 at 478 keV (the Compton edge of 662 keV) for a J-series SiPM operating at an over-voltage of 3V.

47 OTHER INSTRUMENTATION↗

Characterization of a silicon photo-multiplier array with summing board as a photo-multiplier tube replacement in organic scintillator assemblies

In this work, we report on the energy, timing, and pulse-shape discrimination performance of cylindrical 5.08 cm diameter x 5.08 cm thick and 7.62 cm diameter x 7.62 cm thick trans-stilbene crystals read out with the passively summed output of three different commercial silicon photo-multiplier arrays. Our results indicate that using the summed output of an 8 x 8 array of SiPMs provides performance competitive with photo-multiplier tubes for many neutron imaging and correlated particle measurements. For a 5.08 cm diameter x 5.08 cm thick crystal read out with SensL’s ArrayJ-60035_64P-PCB, which had the best overall properties, we measure the energy resolution as 17.8 ± 0.8% at 341 keVee (σ/E), the timing resolution in the 180–400 keVee range as 236 ± 61 ps (σ), and the pulse-shape discrimination figure-of-merit as 2.21 ± 0.03 in the 230–260 keVee energy range. For a 7.62 cm diameter x 7.62 cm thick crystal read out with SensL’s ArrayJ-60035_64P-PCB, we measure the energy resolution as 21.9 ± 2.3% at 341 keVee, the timing resolution in the 180–400 keVee range as 518 ± 42 ps, and the pulse-shape discrimination figure-of-merit as 1.49 ± 0.01 in the 230–260 keVee energy range. Our findings enable many scintillator-based instruments to enjoy the size, robustness, and power benefits of silicon photo-multiplier arrays as replacement for the photo-multiplier tubes that are predominantly used today.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interaction position, time, and energy resolution in organic scintillator bars with dual-ended readout

We report on the position, timing, and energy resolution of a range of plastic scintillator bars and reflector treatments using dual-ended silicon photomultiplier readout. These measurements are motivated by the upcoming construction of an optically segmented single-volume neutron scatter camera, in which neutron elastic scattering off of hydrogen is used to kinematically reconstruct the location and energy of a neutron-emitting source. For this application, interaction position resolutions of about 10 mm and timing resolutions of about 1 ns are necessary to achieve the desired efficiency for fission-energy neutrons. The results presented here indicate that this is achievable with an array of 5 x 5 x 190 mm 3 bars of EJ-204 scintillator wrapped in Teflon tape, read out with SensL’s J-series 6 x 6 mm 2 silicon photomultipliers. With two independent setups, we also explore the systematic variability of the position resolution, and show that, in general, using the difference in the pulse arrival time at the two ends is less susceptible to systematic variation than using the log ratio of the charge amplitude of the two ends. Finally, we measure a bias in the absolute time of interactions as a function of position along the bar: the measured interaction time for events at the center of the bar is 100 ps later than interactions near the SiPM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Source detection at 100 meter standoff with a time-encoded imaging system

Here, we present the design, characterization, and testing of a laboratory prototype radiological search and localization system. The system, based on time-encoded imaging, uses the attenuation signature of neutrons in time, induced by the geometrical layout and motion of the system. We have demonstrated the ability to detect a ~1 mCi 252 Cf radiological source at 100 m standoff with 90% detection efficiency and 10% false positives against background in 12 min. As a result, this same detection efficiency is met at 15 s for a 40 m standoff, and 1.2 s for a 20 m standoff.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and expected performance of a fast neutron attenuation probe for light element density measurements

In this paper, we present the design and expected performance of a proof-of-concept 32 channel material identification system. Our system is based on the energy-dependent attenuation of fast neutrons for four elements: hydrogen, carbon, nitrogen and oxygen. We describe a new approach to obtaining a broad range of neutron energies to probe a sample, as well as our technique for reconstructing the molar densities within a sample. The system's performance as a function of time-of-flight energy resolution is explored using a Geant4-based Monte Carlo. Our results indicate that, with the expected detector response of our system, we will be able to determine the molar density of all four elements to within a 20–30% accuracy in a two hour scan time. In many cases this error is systematically low, thus the ratio between elements is more accurate. This degree of accuracy is enough to distinguish, for example, a sample of water from a sample of pure hydrogen peroxide: the ratio of oxygen to hydrogen is reconstructed to within 8±0.5% of the true value. Lastly, with future algorithm development that accounts for backgrounds caused by scattering within the sample itself, the accuracy of molar densities, not ratios, may improve to the 5–10% level for a two hour scan time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A search for cosmogenic production of β-neutron emitting radionuclides in water

Here we present the first results of WATCHBOY, a water Cherenkov detector designed to measure the yield of β-neutron emitting radionuclides produced by cosmic ray muons in water. In addition to the β-neutron measurement, we also provide a first look at isolating single-β producing radionuclides following muon-induced hadronic showers as a check of the detection capabilities of WATCHBOY. The data taken over 207 live days indicates a 9 Li production yield upper limit of $1.9\times10^{-7}\mu^{-1}g^{-1}\mathrm{cm}^2$ at $\sim400$ meters water equivalent (m.w.e.) overburden at the 90% confidence level. In this work the 9 Li signal in WATCHBOY was used as a proxy for the combined search for 9 Li and 8 He production. This result will provide a constraint on estimates of antineutrino-like backgrounds in future water-based antineutrino detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of two-dimensional time-encoded imaging of fast neutrons

Here, we present a neutron detector system based on time-encoded imaging, and demonstrate its applicability toward the spatial mapping of special nuclear material. We also demonstrate that two-dimensional fast-neutron imaging with 2° resolution at 2 m stand-off is feasible with only two instrumented detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results from the LUX Dark Matter Experiment at the Sanford Underground Research Facility

The Large Underground Xenon (LUX) experiment is a dual-phase xenon time-projection chamber operating at the Sanford Underground Research Facility (Lead, South Dakota). The LUX cryostat was filled for the first time in the underground laboratory in February 2013. We report here results of the first WIMP search data set, taken during the period from April to August 2013, presenting the analysis of 85.3 live days of data with a fiducial volume of 118 kg. A profile-likelihood analysis technique shows our data to be consistent with the background-only hypothesis, allowing 90% confidence limits to be set on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit on the cross section of 7.6 × 1 0 - 46 cm 2 at a WIMP mass of 33 GeV / c 2 . We find that the LUX data are in disagreement with low-mass WIMP signal interpretations of the results from several recent direct detection experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technical results from the surface run of the LUX dark matter experiment

We present the results of the three-month above-ground commissioning run of the Large Underground Xenon (LUX) experiment at the Sanford Underground Research Facility located in Lead, South Dakota, USA. LUX is a 370 kg liquid xenon detector that will search for cold dark matter in the form of Weakly Interacting Massive Particles (WIMPs). The commissioning run, conducted with the detector immersed in a water tank, validated the integration of the various sub-systems in preparation of the underground deployment. Using the data collected, we report excellent light collection properties, achieving 8.4 photoelectrons per keV for 662 keV electron recoils without an applied electric field, measured in the center of the WIMP target. Here, we also find good energy and position resolution in relatively high-energy interactions from a variety of internal and external sources. Finally, we have used the commissioning data to tune the optical properties of our simulation and report updated sensitivity projections for spin-independent WIMP-nucleon scattering.

79 ASTRONOMY AND ASTROPHYSICS↗

The LUX prototype detector: Heat exchanger development

The LUX (large underground xenon) detector is a two-phase xenon time projection chamber (TPC) designed to search for WIMP–nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large (> 1 ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. Here, we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 m to be achieved in approximately 2 days and sustained for the duration of the testing period.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗