Search NASASearch

Engineering topics

Szepesi, Z.

Publications and source records attributed to Szepesi, Z..

Fabrication and characteristics of experimental radiographic amplifier screens

The fabrication process and transfer characteristics for solid state radiographic image transducers (radiographic amplifier screens) are described. These screens are for use in realtime nondestructive evaluation procedures that require large format radiographic images with contrast and resolution capabilities unavailable with conventional fluoroscopic screens. The screens are suitable for in-motion, on-line radiographic inspection by means of closed circuit television. Experimental effort was made to improve image quality and response to low energy (5 kV and up) X-rays.

Szepesi, Z.

Improvements in solid state radiographic converter screens.

Description of two different kinds of solid-state radiographic converter screens which have been developed. After briefly reviewing the working principles of the solid-state image converter - a sandwich type structure consisting of a photoconductive layer and an electroluminescent layer with a semiconductive layer and a black layer between them, two different kinds of radiographic converter screens are described - a radiographic amplifier screen that can be used as a substitute for the fluoroscopic screen, and a radiographic storage screen that can be used instead of radiographic films. The construction of both kinds of converters is fundamentally the same, the only difference being in the sensing photoconductive material. The radiographic amplifier screen has a moderately fast response, while the radiographic storage screen displays the image long after the irradiation is stopped.

Szepesi, Z.

Solid state radiographic image amplifiers, part C

The contrast sensitivity of the radiographic amplifiers, both the storage type and nonstorage type, their absolute sensitivity, and the reproducibility of fabrication were investigated. The required 2-2T quality level was reached with the radiographic storage screen. The sensitivity threshold was 100 to 200 mR with 45 to 100 kV filtered X-rays. The quality level of the radiographic amplifier screen (without storage) was 4-4T; for a 6 mm (0.25 in.) thick aluminum specimen, a 1 mm (0.040 in.) diameter hole in a 0.25 mm (0.010 in.) thick penetrameter was detected. Its sensitivity threshold was 2 to 6 mR/min. The developed radiographic screens are applicable for uses in nondestructive testing.

Szepesi, Z.