Search NASA⌕ Search

Engineering topics

Szuszczewicz, E. P.

Publications and source records attributed to Szuszczewicz, E. P..

30 records · Page 2

First measurements of electron temperature in the D region with a symmetric double probe

Measurement of the altitude profile of electron temperature in the ionospheric D region with the aid of a symmetric double probe flown on a Nike-Cajun payload launched on Oct. 13, 1971. The procedure for determining the electron temperature from the parameters of the double probe's current-voltage characteristic under conditions of nonnegligible ion-atom collision frequencies is described. It is shown that in its first lower ionospheric application the technique of the symmetric double probe has yielded the lowest values of electron temperature yet measured and has provided the very first direct measurement of electron temperature in the D region.

Szuszczewicz, E. P.↗

Transition region response of the symmetric double probe and its application in the lower ionosphere.

Assessment of the floating double probe technique for in situ measurements of the plasma temperature in the D region of the ionosphere. The effects of ion-atom collisions on the current-voltage characteristic of a symmetric double-probe system are reviewed in connection with the determination of the temperature of a completely thermalized plasma. The manner in which this technique can be implemented for a rocket-borne experiment is described, and an experimental current-voltage characteristic obtained in the earth's lower atmosphere is presented and discussed.

Szuszczewicz, E. P.↗

Fixed-bias floating double-probe technique with simple Langmuir-probe characteristics.

A new floating double-probe method is presented which has advantages over other floated-probe systems heretofore described in the literature. The method utilizes two electrodes, one of constant area and the other with a variable area, and the two-electrode configuration is separated by a fixed bias voltage. The current-voltage characteristics of the new technique, which are generated by varying the area of one electrode, are identical to those of a simple Langmuir probe, thus coupling all the advantages of a floated-probe system with the simple analysis scheme generally applied to the Langmuir probe for the determination of plasma density and temperature.

Szuszczewicz, E. P.↗

Transition region response of the symmetric double probe and its application in the lower ionosphere

The technique is discussed of the symmetric double-probe which readily lends itself to the in situ measurement of plasma temperature in the ionospheric D-region because it can lead to meaningful results under relatively high collision frequencies where the Langmuir probe has been observed to fail. It is shown that the modification to the original collision-free double-probe theory of Johnson and Malter for the determination of electron temperature is never greater than + or - 12%, with a value of (8 + or - 2)% nominally applicable in the case of D-region diagnostics. This technique was successfully operated on a Nike-Cajun payload flown at mid-day from White Sands, New Mexico to an apogee of 78.5 km. The associated electronics and deployed double-probe configuration are presented, and a current-voltage characteristic collected in the ascent stage at 73.7 km is briefly discussed. The values of electron temperature indicated by the sampled data are approximately 30% higher than those predicted by theory for the anticipated state of thermal equilibrium with the ambient neutrals.

Szuszczewicz, E. P.↗

A comparative study of electrical probe techniques for plasma diagnostics

Techniques for using electrical probes for plasma diagnostics are reviewed. Specific consideration is given to the simple Langmuir probe, the symmetric double probe of Johnson and Malter, the variable-area probe of Fetz and Oeschsner, and a floating probe technique. The advantages and disadvantages of each technique are discussed.

Szuszczewicz, E. P.↗

Area influences and floating potentials in Langmuir probe measurements.

Analysis of the influence of a relatively small reference electrode on a Langmuir probe measurement of plasma density and temperature. The analysis employs the collisionless theory of Laframboise for spherical and cylindrical probes and in a completely general way includes a broad range of electron densities and temperatures, as well as all possible values of ion mass and multiplicity of ionization. It is shown that a ratio alpha of reference-electrode area to probe area of 10,000 will guarantee no distortion of the measurement as a result of a shifting reference-electrode potential. It is further shown that the constraint on alpha can be relaxed by approximately two orders of magnitude when the charge-normalized ion mass is decreased from 200 to 1 amu and the ratio of reference-electrode radius to Debye length is decreased from 100 to 0. An additional result of the analysis is the dependence of a probe's floating potential on its geometry and radius, as well as on the properties of the plasma. A discussion of the latter result reveals in a striking manner the significant differences between the ion-current responses of spherical and cylindrical probes.

Szuszczewicz, E. P.↗

A fixed bias, floating double probe technique with simple Langmuir probe characteristics

A new floating double-probe method is presented which has advantages over other floated-probe systems previously described in literature. The method utilized two electrodes, one of constant area and the other with a variable area. The two-electrode configuration is separated by a fixed bias voltage. The current-voltage characteristics of the new technique, which are generated by varying the area of the one electrode, are identical to those of a simple Langmuir probe, thus coupling all the advantages of a floated-probe system with the simple analysis scheme generally applied to the Langmuir probe for the determination of plasma density and temperature.

Szuszczewicz, E. P.↗