Search NASA⌕ Search

Engineering topics

T Usui

Publications and source records attributed to T Usui.

Contamination Control and Assessment Strategy for Martian Moons Exploration (MMX)

Martian Moons eXploration (MMX) is a sample return mission from the Martian moon Phobos. The MMX spacecraft is scheduled for launch in 2026 and return to Earth in 2031. The primary science objective of MMX is to reveal the origin of the Martian moons, thereby advancing the understanding of planetary system formation and material transport in the solar system, as well as to observe processes affecting the circumplanetary and surface environments of Mars. The returned sample will be transported to the curation facility at ISAS/JAXA, and the subsequent curation and sample analysis activity will be conducted. As a sample return mission, MMX requires strict contamination control to prevent the intrusion of terrestrial materials.

H Sugahara↗

Observations of Phobos and Deimos with SpeX at NASA Infrared Telescope Facility

We measured near-infrared (NIR) reflectance spectra of Phobos and Deimos, using the prism (0.7–2.52 μm) and long-wavelength cross dispersed (LXD: 1.9–4.2 μm) modes of NASA Infrared Telescope Facility (IRTF)’s SpeX instrument. The goal of this study is to investigate the surface composition of Phobos and Deimos and search for any mineralogical absorption signatures that may be present on their surfaces, especially in the LXD spectral range. Prism spectra of Phobos showed significant slope variation at shorter wavelengths (λ <1.3 μm), which indicates surface heterogeneity possibly due to regolith’s composition and grain size, and/or space weathering. Deimos’ prism spectra were found to be consistent with the more red-sloped prism spectra of Phobos. The measured LXD spectra of Deimos revealed evidence of hydration with 3-μm band depths at 2.90 μm of 4–5%. The 3-μm band in Deimos could be attributed to exogenic sources such as solar wind implantation or OH-bearingimpactors, or to an endogenic source and the presence of carbonaceous material on its surface. Phobos’ andDeimos’ prism and LXD spectra, however, show no indications for absorption signatures of mafic silicates (i.e.,pyroxene, olivine), organics nor carbonates.

D Takir↗

3-μm Spectroscopy of Phobos and Deimos

The origin of the Martian moons Phobos and Deimos is still not well understood and two scenarios have been proposed for their formation: in-situ and captured asteroid[1]. The in-situ scenario suggested that Phobos and Deimos were formed from Martian materials by co-accretion with Mars[2] or re-accretion of Mars (e.g.,[3],[4],[5]). The captured asteroid scenario proposed that Phobos and Deimos were formed from captured primitive materials originating from the outer solar system[6, 7]. Previous telescopic data have revealed significant information about Phobos’ and Deimos’ spectral properties [8,9,10,11]. Additionally, spacecraft and spec-trometers such as Observatoire pour la Mineralogie, L’Eau, Les Glaces et l’Activité (OMEGA) onboard Mars Express and the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) onboard Mars Reconnaissance Orbiter (MRO) collected visible to near-infrared imaging spectroscopic data of both Phobos and Deimos [12, 13,14,15]. Results from these investigations show that the two moons are moderately low albedo objects with no significant diagnostic absorptions of common ferrous minerals such as olivine and pyroxene. All these ground-and space-based spectroscopic studies of Phobos and Deimos included a spectral range that did not go beyond ~3.5 μm. Here we present spectra of Phobos and Deimos that cover the ~0.7-4 μmrange to search for signatures of hydrated minerals, organics, and carbonates.

D Takir↗

Pneumatic Sampler (P-SAMPLER) for the Martian Moons Exploration (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos (). The spacecraft will perform close-up remote sensing and observations of both moons, and collect a sample from Phobos for Earth sample return.

D Van Dyne↗

A Study of the Curation Protocol by Sample Analysis Working Team (SAWT) in Martian Moons eXploration (MMX) Project

Japan Aerospace Exploration Agency (JAXA) will launch a spacecraft in 2024 for a sample return mission from Phobos (Martian Moons eXploration: MMX). The major scientific goals of MMX are to constrain (1) the origin of Phobos and Deimos and (2) the evolution of the Mars-moon system [1]. The touchdown operations are planned to be performed twice at different landing sites on the Phobos surface to collect > 10 g of the surface materials [2]. After the return to the Earth, the Phobos samples will be collected from the individual sample canisters and introduced to the clean chamber installed at ISAS (Institute of Space and Astronautical Science). The Sample Analysis Working Team (SAWT) of MMX designed the procedure of Phobos sample analysis mainly conducted by the initial analysis teams [3]. For the next step, the SAWT will define the procedure of the curation process (mostly non-destructive analysis) of the Phobos samples, which will be presented here. The protocols of the Phobos sample curation is illustrated in figure 1. First, the headspace gas from the sample container will be collected during the Quick Analysis phase. The Quick Analysis will be operated by the sampler and curation teams in ISAS/JAXA. The terrestrial leak and contamination from the sampling systems will be tested using a quadrupole mass spectrometer equipped with a gas sampling system. Second, the bulk Phobos sample will be observed in the clean chamber under purified-N2 gas with an ambient condition (Pre-basic Characterization). This phase will be operated by the curation team in ISAS/JAXA and the instrument team of the MMX mission. The consistency between the data from the instruments in the clean chamber and the spacecraft will then be evaluated. Subsequently, the curation will distribute the small amount of Phobos samples to the Initial analysis team of MMX to conduct the "Preliminary Examination". The objectives of the preliminary examination are to provide (1) feedback on the subsequent sample allocation process, (2) preliminary scientific results that will address parts of MMX mission goals, and (3) evaluation of the sampling system and terrestrial alteration on Phobos samples. Because multiple models are proposed for the origin of Phobos [1] (e.g., giant impact, the capture of asteroids), the chemical and mineralogical characteristics of Phobos must be assessed before the allocation of the samples to the individual initial analysis teams. Simultaneously, the curation team in JAXA will observe the individual grains and aliquots of the samples in the clean chamber (Basic Characterization).

R Fukai↗

The Mars Sample Return Analogue Collection

The Mars 2020 Perseverance rover touched down in Jezero crater on February 18th, 2021, and sealed the first sample for Mars Sample Return (MSR) later that summer. As of sol 1088, 23 rock cores have been collected across a diverse set of lithologies that span rock types from sedimentary to igneous. As the cache on Perseverance continues to grow, the overall portfolio of MSR expands, creating long lasting implications for a wide net in the scientific community as well as supporting detailed analyses for generations to come. To best prepare for these precious samples to return to Earth one day, NASA and ESA are jointly planning to create a MSR Analogue Collection that will be available to the community in the near future.

M T Thorpe↗