Search NASA⌕ Search

Engineering topics

Tabares-Velasco, Paulo Cesar

Publications and source records attributed to Tabares-Velasco, Paulo Cesar.

Ambient energy for buildings: Beyond energy efficiency

The following Key Messages comprise the salient findings of this study: 1. Ambient energy (from sun, air, ground, and sky) can heat and cool buildings; provide hot water, ventilation and daylighting; dry clothes; and cook food. These services account for about three-quarters of building energy consumption and a third of total US demand. Biophilic design (direct and indirect connections with nature) is an intrinsic adjunct to ambient energy systems, and improves wellness and human performance. 2. The current strategy of electrification and energy efficiency for buildings will not meet our climate goals, because the transition to an all-renewable electric grid is too slow. Widespread adoption of ambient energy is needed. Solar-heated buildings also flatten the seasonal demand for electricity compared to all-electric buildings, reducing required production capacity and long-term energy storage. In addition, ambient-conditioned buildings improve resilience by remaining livable during power outages. 3. National policies, incentives, and marketing should be enacted to promote ambient energy use. Federal administrative priorities should reflect the importance of ambient energy for buildings. Use of ambient energy should be encouraged through existing and new building codes and standards. 4. Ambient energy system design tools are needed for architects, engineers, builders, building scientists, realtors, appraisers, and consumers. PVWatts is used over 100 million times per year for photovoltaic system design. A similar, simple, and accessible tool for ambient design is crucial. 5. Training on ambient energy is needed throughout secondary, post-secondary, and continuing education for workforce development. Currently, only about 10% of colleges teach courses on passive heating and cooling systems. 6. Ambient-conditioned buildings should be demonstrated in all US climate zones. Performance should be monitored and reported, with quantitative case studies made widely available. 7. While current technology is sufficient to build high-performance ambient buildings now, research is needed to develop new technologies to harness ambient energy more effectively and more economically. Such advancements will facilitate adoption of ambient energy technologies in a wider range of buildings, including retrofits. Examples include windows with much lower thermal losses, use of the building shell as thermal storage, alternative light-weight thermal storage systems, sky radiation cooling systems, automated controls for solar gains and passive cooling, and ground coupling.

14 SOLAR ENERGY↗

Optimizing mixed cool thermal storage systems across a connected community

A high level of electric demand flexibility must be integrated into our building infrastructure to enable greater renewable energy penetration in the grid. In the U.S., 9% of electricity generated is used to cool buildings in a periodic manner, making this end-use an ideal target for active management through cool thermal energy storage (CTES) technologies. Historic uses for CTES are designed around central chilled water plants, but these systems cool less than 25% of U.S. commercial floorspace. Emerging technologies are under development to serve the many smaller distributed cooling systems, such as rooftop units (RTUs), and have the potential to add CTES to an additional 66% of cooled commercial floorspace. However, these unitary thermal storage systems (UTSS) lack the modeling and analysis tools to evaluate them in the future interactive grid context. Here, this study develops the modeling and optimization tools necessary to simultaneously examine central and distributed ice storage systems within the multi-building, connected community context. An integrated simulation-optimization workflow is created to allow for rapid customized analysis. Results demonstrate the energy and flexibility tradeoffs of various implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

Design and dispatch optimization of packaged ice storage systems within a connected community

The traditional implementation of cool thermal energy storage (CTES) must be reimagined within the context of a dynamic grid and smart buildings operating as connected communities. As most buildings do not operate central chillers or connect to district cooling loops, this necessitates a broader use of packaged CTES. Our objective is to begin answering the question of how such packaged CTES should be implemented within a connected community. We do so by presenting a simulation–optimization workflow employing building energy modeling software and a mixed-integer linear program to design and dispatch a packaged CTES technology to achieve minimum total annual cost. We demonstrate this methodology on a seven-building case study using current utility rates and find that total annual cooling energy costs can be reduced by 17.8% compared to baseline, after accounting for the cost of storage. We perform three parametric sensitivity studies to evaluate modeling assumptions and obtain the prioritization of storage procurement as a function of annualized life-cycle cost of storage. We find that a community optimization approach provides significantly different results than individual building optimizations and provides greater savings compared to baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Renewable energy analysis in indigenous communities using bottom-up demand prediction

This paper provides a methodology for the holistic analysis of hybrid renewable energy systems in rural communities. Electric demand is an important component for modeling and analysis of renewable energy systems. Typically, electric demand data is not available due to the internal privacy policies of utility providers. Therefore, this study proposes the use of bottom-up approaches for the development of the electric demand profile, considering the general homogeneity of residential and commercial buildings in rural communities. As a test case, this study develops the electric demand profile and investigates the technical and environmental feasibility of a hybrid renewable energy system for the New Town community on the Fort Berthold Indian Reservation (FBIR) in North Dakota. This study conducts the hybrid renewable energy system’s analysis by developing scripts in the LK scripting language and integrating System Advisor Model software’s open-source modules for modeling of renewable energy systems. Here, the results for the validation testbed of this study show that hybrid renewable resources have higher ratios of energy used for self-consumption to the total energy generated compared to stand-alone wind and PV farms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Empirical validation and comparison of methodologies to simulate micro and macro-encapsulated PCMs in the building envelope

Thermal Energy Storage (TES) has the potential to shift peak electricity demand. Passive TES is usually implemented in building envelope as micro and macro encapsulated phase change materials (PCM) to shift electric energy demand and therefore requires careful heat transfer analysis. Whole building energy modelling with simplified heat transfer analysis has become extremely important for designers, architects, engineers, and researchers to predict energy performance of buildings. It is important to validate PCM modelling algorithms used in building energy programs to quantify their error and prove their capacity to model different PCM encapsulation types. This study uses data from a microencapsulated PCM and two macroencapsulated PCMs (Bio based PCM and hydrate salts) tested in full-scale using the Advanced Multiscale Building Energy Research (AMBER) Lab located at the Colorado School of Mines and is used to validate a numerical algorithm written in MATLAB language. To approximate the heat transfer through a wall assembly with macroencapsulated PCM pouches, several modelling techniques that can reduce 3D heat transfer characteristics to 1D are explored in this research. A parallel path heat transfer modelling approach is found to give the closest agreement with the experimental data for the pouched PCMs in building envelope applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time Step Considerations when Simulating Dynamic Behavior of High Performance Homes

Building energy simulations, especially those concerning pre-cooling strategies and cooling/heating peak demand management, require careful analysis and detailed understanding of building characteristics. Accurate modeling of the building thermal response and material properties for thermally massive walls or advanced materials like phase change materials (PCMs) are critically important.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using the Beopt Automated Residential Simulation Test Suite to Enable Comparative Analysis Between Energy Simulation Engines (Preprint)

Verification and validation are crucial software quality control procedures to follow when developing and implementing models. This is particularly important because a variety of stakeholders rely on accurate predictions from building simulation programs. This study uses the BEopt Automated Residential Simulation Test Suite (BARTS) to facilitate comparison of two energy simulation engines across various building components and includes building models that isolate the impacts of specific components on annual energy consumption. As a case study, BARTS has been used to identify important discrepancies between the engines for several components of the building models. These discrepancies are caused by differences in the algorithms used by the engines or coding errors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and Validation of EnergyPlus Phase Change Material Model for Opaque Wall Assemblies

Phase change materials (PCMs) represent a technology that may reduce peak loads and HVAC energy consumption in buildings. A few building energy simulation programs have the capability to simulate PCMs, but their accuracy has not been completely tested. This study shows the procedure used to verify and validate the PCM model in EnergyPlus using a similar approach as dictated by ASHRAE Standard 140, which consists of analytical verification, comparative testing, and empirical validation. This process was valuable, as two bugs were identified and fixed in the PCM model, and version 7.1 of EnergyPlus will have a validated PCM model. Preliminary results using whole-building energy analysis show that careful analysis should be done when designing PCMs in homes, as their thermal performance depends on several variables such as PCM properties and location in the building envelope.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Impacts of Nonlinear Behavior of PCM When Applied into Building Envelope

Presented at the ASME 2012 6th International Conference on Energy Sustainability & 10th Fuel Cell Science, Engineering and Technology Conference on July 23-26, 2012, this study analyzes the effects a nonlinear enthalpy profile has on thermal performance and expected energy benefits for PCM-enhanced insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation Methodology to Allow Simulated Peak Reduction and Energy Performance Analysis of Residential Building Envelope with Phase Change Materials: Preprint

Phase change materials (PCM) represent a potential technology to reduce peak loads and HVAC energy consumption in residential buildings. This paper summarizes NREL efforts to obtain accurate energy simulations when PCMs are modeled in residential buildings: the overall methodology to verify and validate Conduction Finite Difference (CondFD) and PCM algorithms in EnergyPlus is presented in thisstudy. It also shows preliminary results of three residential building enclosure technologies containing PCM: PCM-enhanced insulation, PCM impregnated drywall and thin PCM layers. The results are compared based on predicted peak reduction and energy savings using two algorithms in EnergyPlus: the PCM and Conduction Finite Difference (CondFD) algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Impacts of Nonlinear Behavior of PCM When Applied into Building Envelope: Preprint

Previous research on phase change materials (PCM) for building applications has been done for several decades resulting in plenty of literature on PCM properties, temperature, and peak reduction potential. Thus, PCMs are a potential technology to reduce peak loads and HVAC energy consumption in buildings. There are few building energy simulation programs that have PCM modeling features, and evenfewer have been validated. Additionally, there is no previous research that indicates the level of accuracy when simulating PCM from a building energy simulation perspective. This study analyzes the effects a nonlinear enthalpy profile has on thermal performance and expected energy benefits for PCM-enhanced insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and Validation of EnergyPlus Conduction Finite Difference and Phase Change Material Models for Opaque Wall Assemblies

Phase change materials (PCMs) represent a potential technology to reduce peak loads and HVAC energy consumption in buildings. There are few building energy simulation programs that have the capability to simulate PCM but their accuracy has not been completely tested. This report summarizes NREL efforts to develop diagnostic tests cases to obtain accurate energy simulations when PCMs are modeled in residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Verification and Validation of EnergyPlus Conduction Finite Difference and Phase Change Material Models for Opaque Wall Assemblies

Phase change materials (PCMs) represent a potential technology to reduce peak loads and HVAC energy consumption in buildings. There are few building energy simulation programs that have the capability to simulate PCM but their accuracy has not been completely tested. This report summarizes NREL efforts to develop diagnostic tests cases to obtain accurate energy simulations when PCMs are modeled in residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗