Search NASA⌕ Search

Engineering topics

Takahashi, H

Publications and source records attributed to Takahashi, H.

At least 19 records

SU-C-BRC-05: Monte Carlo Calculations to Establish a Simple Relation of Backscatter Dose Enhancement Around High-Z Dental Alloy to Its Atomic Number

Purpose: To establish a simple relation of backscatter dose enhancement around a high-Z dental alloy in head and neck radiation therapy to its average atomic number based on Monte Carlo calculations. Methods: The PHITS Monte Carlo code was used to calculate dose enhancement, which is quantified by the backscatter dose factor (BSDF). The accuracy of the beam modeling with PHITS was verified by comparing with basic measured data namely PDDs and dose profiles. In the simulation, a high-Z alloy of 1 cm cube was embedded into a tough water phantom irradiated by a 6-MV (nominal) X-ray beam of 10 cm × 10 cm field size of Novalis TX (Brainlab). The ten different materials of high-Z alloys (Al, Ti, Cu, Ag, Au-Pd-Ag, I, Ba, W, Au, Pb) were considered. The accuracy of calculated BSDF was verified by comparing with measured data by Gafchromic EBT3 films placed at from 0 to 10 mm away from a high-Z alloy (Au-Pd-Ag). We derived an approximate equation to determine the relation of BSDF and range of backscatter to average atomic number of high-Z alloy. Results: The calculated BSDF showed excellent agreement with measured one by Gafchromic EBT3 films at from 0 to 10 mm away from the high-Z alloy. We found the simple linear relation of BSDF and range of backscatter to average atomic number of dental alloys. The latter relation was proven by the fact that energy spectrum of backscatter electrons strongly depend on average atomic number. Conclusion: We found a simple relation of backscatter dose enhancement around high-Z alloys to its average atomic number based on Monte Carlo calculations. This work provides a simple and useful method to estimate backscatter dose enhancement from dental alloys and corresponding optimal thickness of dental spacer to prevent mucositis effectively.

60 APPLIED LIFE SCIENCES↗

SU-E-T-50: A Multi-Institutional Study of Independent Dose Verification Software Program for Lung SBRT

Purpose: The accuracy of dose distribution depends on treatment planning system especially in heterogeneity-region. The tolerance level (TL) of the secondary check using the independent dose verification may be variable in lung SBRT plans. We conducted a multi-institutional study to evaluate the tolerance level of lung SBRT plans shown in the AAPM TG114. Methods: Five institutes in Japan participated in this study. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, JP), which is Clarkson-based and CT images were used to compute radiological path length. Analytical Anisotropic Algorithm (AAA), Pencil Beam Convolution with modified Batho-method (PBC-B) and Adaptive Convolve (AC) were used for lung SBRT planning. A measurement using an ion-chamber was performed in a heterogeneous phantom to compare doses from the three different algorithms and the SMU to the measured dose. In addition to it, a retrospective analysis using clinical lung SBRT plans (547 beams from 77 patients) was conducted to evaluate the confidence limit (CL, Average±2SD) in dose between the three algorithms and the SMU. Results: Compared to the measurement, the AAA showed the larger systematic dose error of 2.9±3.2% than PBC-B and AC. The Clarkson-based SMU showed larger error of 5.8±3.8%. The CLs for clinical plans were 7.7±6.0 % (AAA), 5.3±3.3 % (AC), 5.7±3.4 % (PBC -B), respectively. Conclusion: The TLs from the CLs were evaluated. A Clarkson-based system shows a large systematic variation because of inhomogeneous correction. The AAA showed a significant variation. Thus, we must consider the difference of inhomogeneous correction as well as the dependence of dose calculation engine.

60 APPLIED LIFE SCIENCES↗

A multilayer grating with a novel layer structure for a flat-field spectrograph attached to transmission electron microscopes in energy region of 2-4 keV

A multilayer mirror with a novel layer structure to uniformly enhance the reflectivity in a few keV energy range at a fixed angle of incidence is invented and applied to a multilayer grating for use in a flat-field spectrograph attached to a conventional electron microscope. The diffraction efficiency of the fabricated multilayer grating having the new layer structure is evaluated at the angle of incidence of 88.65 deg. in the energy region of 2.1-4.0 keV. It is shown that the multilayer grating is effective to uniformly enhance the diffraction efficiency and able to be practically used in this energy region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of High-Power, Long-Pulse Gyrotrons and Its Application for High Electron Temperature, EBWH and ECCD Experiments on LHD

To sustain plasmas with higher parameters and with longer pulse duration in LHD, ECH system has been upgraded by introducing newly developed 77 GHz gyrotrons. The designed output power and operation duration time are over 1 MW for several seconds and 0.3 MW for continuous operation, respectively. Owing to the upgrade of gyrotrons and improved power supply operation procedure, total injection power of EC-waves to LHD increased up to 3.7 MW at the last LHD experimental campaign in 2010.Application of the high-power 77 GHz EC-waves of 3.4 MW as focused beams to the center of plasma with low line-average electron density of {approx}0.2x10{sup 19} m{sup -3} causes highly steep electron temperature profile and the central electron temperature reached up to 20 keV, which highly exceeds the former record of 15 keV. At higher density region of 1x10{sup 19} m{sup -3}, central electron temperature reached 8.6 keV.Additional electron Bernstein wave heatings, O-X-B and slow X-B heatings, using a 77 GHz ECH system caused clear increase in plasma stored energy even for the high-density plasmas over plasma cutoff (>7.35x10{sup 19} m{sup -3}) sustained with NBI. For the O-X-B scenario, the 77 GHz EC-wave was obliquely injected from low-field side in O-mode polarization, aiming at the point where high mode-conversion efficiency was expected. For realizing slow X-B scenario, new inner-vessel mirrors were installed in LHD just close to a helical coil, that is, at the high-field side (HFS) region. Using the inner-vessel mirror, X-mode waves were injected from HFS, showing evident increase in plasma stored energy.Oblique injection of long-pulse 0.77 MW/8 s 77 GHz wave with various N{sub ||} clearly demonstrated ECCD in LHD. The EC-driven current changes its direction with the sign of N{sub ||}, and the highest EC-driven current reached up to 42 kA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Techniques for the measurement of disruption halo currents in the National Spherical Torus Experiment

This paper describes techniques for measuring halo currents, and their associated toroidal peaking, in the National Spherical Torus Experiments [M. Ono et al., Nucl. Fusion 40, 557 (2000)]. The measurements are based on three techniques: (1) measurement of the toroidal field created by the poloidal halo current, either with segmented Rogowski coils or discrete toroidal field sensors, (2) the direct measurement of halo currents into specially instrument tiles, and (3) small Rogowski coils placed on the mechanical supports of in-vessel components. For the segmented Rogowski coils and discrete toroidal field detectors, it is shown that the toroidal peaking factor inferred from the data is significantly less than the peaking factor of the underlying halo current distribution, and a simple model is developed to relate the two. For the array of discrete toroidal field detectors and small Rogowski sensors, the compensation steps that are used to isolate the halo current signal are described. The electrical and mechanical design of compact under-tile resistive shunts and mini-Rogowski coils is described. Example data from the various systems are shown.

42 ENGINEERING↗

Measurement of the {sup 8}B solar neutrino flux with the KamLAND liquid scintillator detector

We report a measurement of the neutrino-electron elastic scattering rate from {sup 8}B solar neutrinos based on a 123 kton-day exposure of KamLAND. The background-subtracted electron recoil rate, above a 5.5-MeV analysis threshold is 1.49 {+-} 0.14(stat) {+-} 0.17(syst) events per kton-day. Interpreted as due to a pure electron flavor flux with a {sup 8}B neutrino spectrum, this corresponds to a spectrum integrated flux of 2.77 {+-} 0.26(stat) {+-} 0.32(syst) x10{sup 6} cm{sup -2}s{sup -1}. The analysis threshold is driven by {sup 208}Tl present in the liquid scintillator, and the main source of systematic uncertainty is due to background from cosmogenic {sup 11}Be. The measured rate is consistent with existing measurements and with standard solar model predictions which include matter-enhanced neutrino oscillation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A study of extraterrestrial antineutrino sources with the KamLAND detector

We present the results of a search for extraterrestrial electron antineutrinos ({bar {nu}}{sub e}'s) in the energy range 8.3 MeV < E{sub {bar {nu}}}{sub e} < 30.8 MeV using the KamLAND detector. In an exposure of 4.53 kton-year, we identify 25 candidate events. All of the candidate events can be attributed to background, most importantly neutral current atmospheric neutrino interactions, setting an upper limit on the probability of {sup 8}B solar {nu}{sub e}'s converting into {bar {nu}}{sub e}'s at 5.3 x 10{sup -5} (90% C.L.). The present data also allows us to set more stringent limits on the diffuse supernova neutrino flux and on the annihilation rates for light dark matter particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser-shock compression and Hugoniot measurements of liquid hydrogen to 55 GPa

The principal Hugoniot for liquid hydrogen was obtained up to 55 GPa under laser-driven shock loading. The pressure and density of compressed hydrogen were determined by impedance matching to a quartz standard. The shock temperature was independently measured from the brightness of the shock front. Hugoniot data of hydrogen provide a good benchmark to modern theories of condensed matter. The initial number density of liquid hydrogen is lower than that for liquid deuterium, and this results in shock-compressed hydrogen having a higher compression and higher temperature than deuterium at the same shock pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improvements of data quality of the LHD Thomson scattering diagnostics in high-temperature plasma experiments

In Large Helical Device (LHD) experiments, an electron temperature (T{sub e}) more than 15 keV has been observed by the yttrium-aluminum-garnet (YAG) laser Thomson scattering diagnostic. Since the LHD Thomson scattering system has been optimized for the temperature region, 50 eV{<=}T{sub e}{<=}10 keV, the data quality becomes worse in the higher T{sub e} region exceeding 10 keV. In order to accurately determine T{sub e} in the LHD high-T{sub e} experiments, we tried to increase the laser pulse energy by simultaneously firing three lasers. The technique enables us to decrease the uncertainties in the measured T{sub e}. Another signal accumulation method was also tested. In addition, we estimated the influence of high-energy electrons on T{sub e} obtained by the LHD Thomson scattering system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced Constraints on theta13 from A Three-Flavor Oscillation Analysis of Reactor Antineutrinos at KamLAND

We present new constraints on the neutrino oscillation parameters {Delta}m{sub 21}{sup 2}, {theta}{sub 12}, and {theta}{sub 13} from a three-flavor analysis of solar and KamLAND data. The KamLAND data set includes data acquired following a radiopurity upgrade and amounts to a total exposure of 3.49 x 10{sup 32} target-proton-year. Under the assumption of CPT invariance, a two-flavor analysis ({theta}{sub 13} = 0) of the KamLAND and solar data yields the best-fit values tan{sup 2} {theta}{sub 12} = 0.444{sub -0.030}{sup +0.036} and {Delta}m{sub 21}{sup 2} = 7.50{sub -0.20}{sup +0.19} x 10{sup -5} eV{sup 2}; a three-flavor analysis with {theta}{sub 13} as a free parameter yields the best-fit values tan{sup 2} {theta}{sub 12} = 0.452{sub -0.033}{sup +0.035}, {Delta}m{sub 21}{sup 2} = 7.50{sub -0.20}{sup +0.19} x 10{sup -5}eV{sup 2}, and sin{sup 2} {theta}{sub 13} = 0.020{sub -0.016}{sup +0.016}. This {theta}{sub 13} interval is consistent with other recent work combining the CHOOZ, atmospheric and long-baseline accelerator experiments. We also present a new global {theta}{sub 13} analysis, incorporating the CHOOZ, atmospheric and accelerator data, which indicates sin{sup 2} {theta}{sub 13} = 0.017{sub -0.009}{sup +0.010}, a nonzero value at the 93% C.L. This finding will be further tested by upcoming accelerator and reactor experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fine-structure characteristics in the emittance images of a strongly focusing He{sup +} beam

The phase space distribution of a strongly focused He{sup +} ion beam source equipped with concave multiaperture electrodes was measured using a pepper-pot plate and a Kapton foil. The substructure of 301 merging He beamlets was clearly observed on a footprint of pepper-pot hole at the beam waist, where the beam density was 500 mA/cm{sup 2}. The position and the width of each beamlet substructure show the effect of interference of beamlets with surrounding one.

43 PARTICLE ACCELERATORS↗

A multichannel time-of-flight system for observation of energetic ions of multispecies generated from relativistic laser plasma

A multichannel time-of-flight (TOF) system was constructed to observe the ions generated from relativistic laser plasma, where the ions have polychromatic energies and multiple species. The TOF system is composed of a ten-channel scintillation detector array and an electromagnet that generates a magnetic field of 0-1.24 T. The magnet field enables us to analyze protons, deuterons, and full-stripped carbon ions to 50, 25, and 150 MeV, respectively. The system experimentally identified protons of 0.27-1.6 MeV energy and ions of a half specific charge (deuterons of 0.3-0.8 MeV and full-stripped carbons of 1.8-4.8 MeV). The measured TOF values agree well with the calculated values within the designed accuracy; {+-}2.5 ns for protons and {+-}5 ns for the others (d or C{sup 6+}) on each detector channel. Comparison of ion numbers detected by a track detector (CR-39) and the TOF system enabled us to obtain the number of ions detected on each scintillation counter with less than 16% error.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IS THE BLACK HOLE IN GX 339-4 REALLY SPINNING RAPIDLY?

The wide-band Suzaku spectra of the black hole (BH) binary GX 339-4, acquired in 2007 February during the Very High state, were reanalyzed. Effects of event pileup (significant within approx3' of the image center) and telemetry saturation of the X-ray Imaging Spectrometer (XIS) data were carefully considered. The source was detected up to approx300 keV, with an unabsorbed 0.5-200 keV luminosity of 3.8 x 10{sup 38} erg s{sup -1} at 8 kpc. The spectrum can be approximated by a power law of photon index 2.7, with a mild soft excess and a hard X-ray hump. When using the XIS data outside 2' of the image center, the Fe K line appeared extremely broad, suggesting a high BH spin as already reported by Miller et al. based on the same Suzaku data and other CCD data. When the XIS data accumulation is further limited to >3' to avoid event pileup, the Fe K profile becomes narrower, and a marginally better solution appears which suggests that the inner disk radius is 5-14 times the gravitational radius (1sigma), though a maximally spinning BH is still allowed by the data at the 90% confidence level. Consistently, the optically thick accretion disk is inferred to be truncated at a radius 5-32 times the gravitational radius. Thus, the Suzaku data allow an alternative explanation without invoking a rapidly spinning BH. This inference is further supported by the disk radius measured previously in the High/Soft state.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Transition Edge Sensor Gamma Ray Microcalorimeter with an Epoxy Coupled Bulk Lead Absorber

Transition edge sensor (TES)-based gamma ray detectors have been developed primarily for use up to energies of {approx}100 keV. However, there are many interesting applications at higher energies. We have started to develop a TES gamma-ray detector to apply to Positron Annihilation Spectroscopy analysis at 511 keV. Our detector is composed of a bulk lead absorber, which is coupled to a thin-film TES using a small amount of epoxy. The response of our first detector showed a very long decay tail of {approx}135 ms. To improve the device response time we have designed a new detector in which the response time is improved by a factor of five.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Activities on Realization of High-Power and Steady-State ECRH System and Achievement of High Performance Plasmas in LHD

Electron Cyclotron Resonance Heating (ECRH) has contributed to the achievement of high performance plasma production, high electron temperature plasmas and sustainment of steady-state plasmas in the Large Helical Device (LHD). Our immediate targets of upgrading the ECRH system are 5 MW several seconds and 1 MW longer than one hour power injection into LHD. The improvement will greatly extend the plasma parameter regime. For that purpose, we have been promoting the development and installation of 77 GHz/1-1.5 MW/several seconds and 0.3 MW/CW gyrotrons in collaboration with University of Tsukuba. The transmission lines are re-examined and improved for high and CW power transmission. In the recent experimental campaign, two 77 GHz gyrotrons were operated. One more gyrotron, which was designed for 1.5 MW/2 s output, was constructed and is tested. We have been promoting to improve total ECRH efficiency for efficient gyrotron-power use and efficient plasma heating, e.g. a new waveguide alignment method and mode-content analysis and the feedback control of the injection polarization. In the last experimental campaign, the 77 GHz gyrotrons were used in combination with the existing 84 GHz range and 168 GHz gyrotrons. Multi-frequency ECRH system is more flexible in plasma heating experiments and diagnostics. A lot of experiments have been performed in relation to high electron temperature plasmas by realization of the core electron-root confinement (CERC), electron cyclotron current drive (ECCD), Electron Bernstein Wave heating, and steady-state plasma sustainment. Some of the experimental results are briefly described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of CERC using newly installed 77 GHz Gyrotron in LHD

We have investigated the transition to Core Electron-Root Confinement (CERC) using the 77 GHz ECRH system, which was newly installed in the Large Helical Device (LHD). The focal point scan of the ECRH was carried out shot by shot in the same poloidal surface along the magnetic field of 2.75 T, which is the fundamental resonance surface for 77 GHz ECRH. The formation of the steep gradient in the electron temperature and the change of the radial electric field from negative to positive value in the plasma core region were observed by the ECRH injection to {rho}<0.5. The foot point of the peaked profile of the electron temperature appeared near the m/n = 2/1 rational surface, which was located at {rho}{approx}0.5. These results imply that localized ECRH in the inner region within the lower order rational surface and/or the electron heat flux across the rational surface play important roles for the transition to CERC. We also confirmed that the calculated radial electric field from a neoclassical theory qualitatively agreed with the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗