X-Ray Polarization of the High-synchrotron-peak BL Lacertae Object 1ES 1959+650 during Intermediate and High X-Ray Flux States
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Takao Kitaguchi.
Explore the source record for details and available documents.
In intermediate polars (IPs), the intrinsic thermal emissions from white dwarfs (WDs) have typically been studied. Few reports have analysed X-ray reflections from WDs. We recently developed an elaborate IP-reflection spectral model. Herein, we report the first application of a reflection model with an IP thermal model to the spectra of the brightest typical IP V1223 Sagittarii observed by the Suzaku and Nuclear Spectroscopic Telescope Array satellites. The model reasonably reproduces the spectra within the range of 5–78 keV and estimates the WD mass as 0.92 ± 0.02 Mꙩ. The WD mass estimated by the proposed model is consistent with that measured using an active galactic nucleus reflection model and a partial covering absorption model. However, the choice of incorrect parameter values, such as an unsuitable fitting energy band and an incorrect metal abundance, was found to introduce systematic errors (e.g. ≲0.2 Mꙩ in the WD mass) in the WD mass measurement. Our spin-phase-resolved analysis resulted in discoveries regarding the modulations of the equivalent width of the fluorescent iron K α line and the angle between the post-shock accretion column and the line of sight (viewing angle). The viewing angle anticorrelates approximately with the X-ray flux and has average and semi-amplitude values of 55° and 7°, respectively, which points towards two WD spin axis angles from the line of sight of 55° and 7°, respectively. Both estimated spin axis angles are different from the reported system inclination of 24°.
We present the first application of a time projection chamber polarimeter to measure high energy X-ray polarization above 10 keV. The polarimeter is designed based on the PRAXyS soft X-ray polarimeter. The sealed gas is changed to a gas mixture of 60% argon and 40% dimethyl ether at 1 atm to be sensitive to high energy X-rays. The polarimeter performance is verified with linearly polarized, monochromatic X-rays at a synchrotron radiation facility, KEK Photon Factory BL-14A. The measured modulation factors are 42.4±0.6%, 50.4±0.6%,and 55.0±0.6% at 12, 14, and 16 keV, respectively, and the measured polarization angles are consistent with the expected values at all energies.
The X-Ray Imaging and Spectroscopy Mission, XRISM, is currently scheduled to launch in 2022 with the objective of building on the brief, but significant, successes of the ASTRO-H (Hitomi) mission in solving outstanding astrophysical questions using high resolution X-ray spectroscopy. The XRISM Science Operations Team (SOT) consists of the JAXA-led Science Operations Center (SOC) and NASA-led Science Data Center (SDC), which work together to optimize the scientific output from the Resolve high-resolution spectrometer and the Xtend wide-field imager through planning and scheduling of observations, processing and distribution of data, development and distribution of software tools and the calibration database (CaldB), support of ground and in-flight calibration, and support of XRISM users in their scientific investigations of the energetic universe. Here, we summarize the roles and responsibilities of the SDC and its current status and future plans. The Resolve instrument poses particular challenges due to its unprecedented combination of high spectral resolution and throughput, broad spectral coverage, and relatively small field-of-view and large pixel-size. We highlight those challenges and how they are being met.
Explore the source record for details and available documents.
We present deep (>2.4 Ms) observations of the Cassiopeia A supernova remnant with NuSTAR, which operates in the 3-79 keV bandpass and is the first instrument capable of spatially resolving the remnant above 15 keV. We find that the emission is not entirely dominated by the forward shock nor by a smooth "bright ring" at the reverse shock. Instead we find that the >15 keV emission is dominated by knots near the center of the remnant and dimmer filaments near the remnant's outer rim. These regions are fit with unbroken power laws in the 15-50 keV bandpass, though the central knots have a steeper (Gamma approx. −3.35) spectrum than the outer filaments (Gamma approx. −3.06). We argue this difference implies that the central knots are located in the 3-D interior of the remnant rather than at the outer rim of the remnant and seen in the center due to projection effects. The morphology of >15 keV emission does not follow that of the radio emission nor that of the low energy (<12 keV) X-rays, leaving the origin of the >15 keV emission an open mystery. Even at the forward shock front we find less steepening of the spectrum than expected from an exponentially cut off electron distribution with a single cutoff energy. Finally, we find that the GeV emission is not associated with the bright features in the NuSTAR band while the TeV emission may be, suggesting that both hadronic and leptonic emission mechanisms may be at work.
The Nuclear Spectroscopic Telescope Array (NuSTAR) is the first focusing hard X-ray mission in orbit and operates in the 3-79 keV range. NuSTAR's sensitivity is roughly two orders of magnitude better than previous missions in this energy band thanks to its superb angular resolution. Since its launch in 2012 June, NuSTAR has performed excellently and observed many interesting sources including four magnetars, two rotation-powered pulsars and the cataclysmic variable AE Aquarii. NuSTAR also discovered 3.76-s pulsations from the transient source SGR J1745−29 recently found by Swift very close to the Galactic Center, clearly identifying the source as a transient magnetar. For magnetar 1E 1841−045, we show that the spectrum is well fit by an absorbed blackbody plus broken power-law model with a hard power-law photon index of approximately 1.3. This is consistent with previous results by INTEGRAL and RXTE. We also find an interesting double-peaked pulse profile in the 25-35 keV band. For AE Aquarii, we show that the spectrum can be described by a multi-temperature thermal model or a thermal plus non-thermal model; a multi-temperature thermal model without a non-thermal component cannot be ruled out. Furthermore, we do not see a spiky pulse profile in the hard X-ray band, as previously reported based on Suzaku observations. For other magnetars and rotation-powered pulsars observed with NuSTAR, data analysis results will be soon available.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.