SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

60 APPLIED LIFE SCIENCES↗

SU-F-T-96: A New Paradigm of Weekly Chart Checking for Radiation Therapy Clinics

Purpose: To put forth an innovative clinical paradigm for weekly chart checking so that treatment status is periodically checked accurately and efficiently. This study also aims to help optimize the chart checking clinical workflow in a busy radiation therapy clinic. Methods: It is mandated by the Texas Administrative code to check patient charts of radiation therapy once a week or every five fractions, however it varies drastically among institutions in terms of when and how it is done. Some do it every day, but a lot of efforts are wasted on opening ineligible charts; some do it on a fixed day but the distribution of intervals between subsequent checks is not optimal. To establish an optimal chart checking procedure, a new paradigm was developed to achieve 1) charts are checked more accurately and more efficiently; 2) charts are checked on optimal days without any miss; 3) workload is evened out throughout a week when multiple physicists are involved. All active charts will be accessed by querying the R&V system. Priority is assigned to each chart based on the number of days before the next due date followed by sorting and workload distribution steps. New charts are also taken into account when distributing the workload so it is reasonably even throughout the week. Results: Our clinical workflow became more streamlined and smooth. In addition, charts get checked in a more timely fashion so that errors would get caught earlier should they occur. Conclusion: We developed a new weekly chart checking diagram. It helps physicists check charts in a timely manner, saves their time in busy clinics, and consequently reduces possible errors.

60 APPLIED LIFE SCIENCES↗

SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

60 APPLIED LIFE SCIENCES↗

MO-FG-202-08: Real-Time Monte Carlo-Based Treatment Dose Reconstruction and Monitoring for Radiotherapy

Purpose: This proof-of-concept study is to develop a real-time Monte Carlo (MC) based treatment-dose reconstruction and monitoring system for radiotherapy, especially for the treatments with complicated delivery, to catch treatment delivery errors at the earliest possible opportunity and interrupt the treatment only when an unacceptable dosimetric deviation from our expectation occurs. Methods: First an offline scheme is launched to pre-calculate the expected dose from the treatment plan, used as ground truth for real-time monitoring later. Then an online scheme with three concurrent threads is launched while treatment delivering, to reconstruct and monitor the patient dose in a temporally resolved fashion in real-time. Thread T1 acquires machine status every 20 ms to calculate and accumulate fluence map (FM). Once our accumulation threshold is reached, T1 transfers the FM to T2 for dose reconstruction ad starts to accumulate a new FM. A GPU-based MC dose calculation is performed on T2 when MC dose engine is ready and a new FM is available. The reconstructed instantaneous dose is directed to T3 for dose accumulation and real-time visualization. Multiple dose metrics (e.g. maximum and mean dose for targets and organs) are calculated from the current accumulated dose and compared with the pre-calculated expected values. Once the discrepancies go beyond our tolerance, an error message will be send to interrupt the treatment delivery. Results: A VMAT Head-and-neck patient case was used to test the performance of our system. Real-time machine status acquisition was simulated here. The differences between the actual dose metrics and the expected ones were 0.06%–0.36%, indicating an accurate delivery. ∼10Hz frequency of dose reconstruction and monitoring was achieved, with 287.94s online computation time compared to 287.84s treatment delivery time. Conclusion: Our study has demonstrated the feasibility of computing a dose distribution in a temporally resolved fashion in real-time and quantitatively and dosimetrically monitoring the treatment delivery.

60 APPLIED LIFE SCIENCES↗

SU-C-304-04: A Compact Modular Computational Platform for Automated On-Board Imager Quality Assurance

Purpose: Traditionally, the assessment of X-ray tube output and detector positioning accuracy of on-board imagers (OBI) has been performed manually and subjectively with rulers and dosimeters, and typically takes hours to complete. In this study, we have designed a compact modular computational platform to automatically analyze OBI images acquired with in-house designed phantoms as an efficient and robust surrogate. Methods: The platform was developed as an integrated and automated image analysis-based platform using MATLAB for easy modification and maintenance. Given a set of images acquired with the in-house designed phantoms, the X-ray output accuracy was examined via cross-validation of the uniqueness and integration minimization of important image quality assessment metrics, while machine geometric and positioning accuracy were validated by utilizing pattern-recognition based image analysis techniques. Results: The platform input was a set of images of an in-house designed phantom. The total processing time is about 1–2 minutes. Based on the data acquired from three Varian Truebeam machines over the course of 3 months, the designed test validation strategy achieved higher accuracy than traditional methods. The kVp output accuracy can be verified within +/−2 kVp, the exposure accuracy within 2%, and exposure linearity with a coefficient of variation (CV) of 0.1. Sub-millimeter position accuracy was achieved for the lateral and longitudinal positioning tests, while vertical positioning accuracy within +/−2 mm was achieved. Conclusion: This new platform delivers to the radiotherapy field an automated, efficient, and stable image analysis-based procedure, for the first time, acting as a surrogate for traditional tests for LINAC OBI systems. It has great potential to facilitate OBI quality assurance (QA) with the assistance of advanced image processing techniques. In addition, it provides flexible integration of additional tests for expediting other OBI quality assurance tests, such as 2D/3D image quality, making completely automated QA possible. Research Funding from Varian Medical Systems Inc. . Dr. Sasa Mutic receives compensation for providing patient safety training services from Varian Medical Systems, the sponsor of this study.

60 APPLIED LIFE SCIENCES↗

SU-D-BRD-02: Auto Weekly - An Automated Online Weekly Chart Check System for Medical Physics

Purpose: Radiation therapy has evolved to become not only more precise and potent, but also more complicated to monitor and deliver. More rigorous and comprehensive quality assurance is needed to safeguard ever advancing radiation therapy. ICRU standards dictate that an ever growing set of treatment parameters are manually checked weekly by medical physicists. This “weekly chart check” procedure is laborious and subject to human errors or other factors. A computer-assisted chart checking process will enable more complete and accurate human review of critical parameters, reduce the risk of medical errors, and improve the efficiency. Methods: We developed a web-based software system that enables a thorough weekly quality assurance checks. In the backend, the software retrieves all machine parameters from a Treatment Management System (TMS) and compares them against the corresponding ones from the treatment planning system. They are also checked for validity against preset rules. The results are displayed as a web page in the front-end for physicists to review. Then a summary report is generated and uploaded automatically to the TMS as a record for weekly chart checking. Results: The software system has been deployed on a web server in our department’s intranet, and has been tested thoroughly by our clinical physicists. A plan parameter would be highlighted when it is off the preset limit. The developed system has changed the way of checking charts with significantly improved accuracy, efficiency, and completeness. It has been shown to be robust, fast, and easy to use. Conclusion: A computer-assisted system has been developed for efficient, accurate, and comprehensive weekly chart checking. The system has been extensively validated and is being implemented for routine clinical use.

60 APPLIED LIFE SCIENCES↗

TU-AB-201-02: An Automated Treatment Plan Quality Assurance Program for Tandem and Ovoid High Dose-Rate Brachytherapy

Purpose: For tandem and ovoid (T&O) HDR brachytherapy in our clinic, it is required that the planning physicist manually capture ∼10 images during planning, perform a secondary dose calculation and generate a report, combine them into a single PDF document, and upload it to a record- and-verify system to prove to an independent plan checker that the case was planned correctly. Not only does this slow down the already time-consuming clinical workflow, the PDF document also limits the number of parameters that can be checked. To solve these problems, we have developed a web-based automatic quality assurance (QA) program. Methods: We set up a QA server accessible through a web- interface. A T&O plan and CT images are exported as DICOMRT files and uploaded to the server. The software checks 13 geometric features, e.g. if the dwell positions are reasonable, and 10 dosimetric features, e.g. secondary dose calculations via TG43 formalism and D2cc to critical structures. A PDF report is automatically generated with errors and potential issues highlighted. It also contains images showing important geometric and dosimetric aspects to prove the plan was created following standard guidelines. Results: The program has been clinically implemented in our clinic. In each of the 58 T&O plans we tested, a 14- page QA report was automatically generated. It took ∼45 sec to export the plan and CT images and ∼30 sec to perform the QA tests and generate the report. In contrast, our manual QA document preparation tooks on average ∼7 minutes under optimal conditions and up to 20 minutes when mistakes were made during the document assembly. Conclusion: We have tested the efficiency and effectiveness of an automated process for treatment plan QA of HDR T&O cases. This software was shown to improve the workflow compared to our conventional manual approach.

60 APPLIED LIFE SCIENCES↗

TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-C-17A-04: BEST IN PHYSICS (THERAPY) - A Supervised Framework for Automatic Contour Assessment for Radiotherapy Planning of Head- Neck Cancer

Purpose: Precise contour delineation of tumor targets and critical structures from CT simulations is essential for accurate radiotherapy (RT) treatment planning. However, manual and automatic delineation processes can be error prone due to limitations in imaging techniques and individual anatomic variability. Tedious and laborious manual verification is hence needed. This study develops a general framework for automatically assessing RT contours for head-neck cancer patients using geometric attribute distribution models (GADMs). Methods: Geometric attributes (centroid and volume) were computed from physician-approved RT contours of 29 head-neck patients. Considering anatomical correlation between neighboring structures, the GADM for each attribute was trained to characterize intra- and interpatient structure variations using principal component analysis. Each trained GADM was scalable and deformable, but constrained by the principal attribute variations of the training contours. A new hierarchical model adaptation algorithm was utilized to assess the RT contour correctness for a given patient. Receiver operating characteristic (ROC) curves were employed to evaluate and tune system parameters for the training models. Results: Experiments utilizing training and non-training data sets with simulated contouring errors were conducted to validate the framework performance. Promising assessment results of contour normality/abnormality for the training contour-based data were achieved with excellent accuracy (0.99), precision (0.99), recall (0.83), and F-score (0.97), while corresponding values of 0.84, 0.96, 0.83, and 0.9 were achieved for the non-training data. Furthermore, the areas under the ROC curves were above 0.9, validating the accuracy of this test. Conclusion: The proposed framework can reliably identify contour normality/abnormality based upon intra- and inter-structure constraints derived from clinically-approved contours. It also allows physicians to analytically determine the system parameters to fit various clinic requirements (e.g. as-low-as-possible false positives). It has great potential for improving RT work flow. More geometric attributes and training sets will be investigated to improve framework performance in the future.

60 APPLIED LIFE SCIENCES↗

TH-A-9A-08: Knowledge-Based Quality Control of Clinical Stereotactic Radiosurgery Treatment Plans

Purpose: To develop a quality control tool to reduce stereotactic radiosurgery (SRS) planning variability using models that predict achievable plan quality metrics (QMs) based on individual patient anatomy. Methods: Using a knowledge-based methodology that quantitatively correlates anatomical geometric features to resultant organ-at-risk (OAR) dosimetry, we developed models for predicting achievable OAR dose-volume histograms (DVHs) by training with a cohort of previously treated SRS patients. The DVH-based QMs used in this work are the gradient measure, GM=(3/4pi)^1/3*[V50%^1/3−V100%^1/3], and V10Gy of normal brain. As GM quantifies the total rate of dose fall-off around the planning target volume (PTV), all voxels inside the patient's body contour were treated as OAR for DVH prediction. 35 previously treated SRS plans from our institution were collected; all were planned with non-coplanar volumetric-modulated arc therapy to prescription doses of 12–25 Gy. Of the 35-patient cohort, 15 were used for model training and 20 for model validation. Accuracies of the predictions were quantified by the mean and the standard deviation of the difference between clinical and predicted QMs, δQM=QM-clin−QM-pred. Results: Best agreement between predicted and clinical QMs was obtained when models were built separately for V-PTV<2.5cc and V-PTV>2.5cc. Eight patients trained the V-PTV<2.5cc model and seven patients trained the V-PTV>2.5cc models, respectively. The mean and the standard deviation of δGM were 0.3±0.4mm for the training sets and −0.1±0.6mm for the validation sets, demonstrating highly accurate GM predictions. V10Gy predictions were also highly accurate, with δV10Gy=0.8±0.7cc for the training sets and δV10Gy=0.7±1.4cc for the validation sets. Conclusion: The accuracy of the models in predicting two key SRS quality metrics highlights the potential of this technique for quality control for SRS treatments. Future investigations will seek to determine whether QM variations are due to residual model inaccuracies or true plan quality variations in the clinical sample. Support from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

TH-C-18A-11: Investigating the Minimum Scan Parameters Required to Generate Free-Breathing Fast-Helical CT Scans Without Motion-Artifacts

Purpose: A recently proposed 4D-CT protocol uses deformable registration of free-breathing fast-helical CT scans to generate a breathing motion model. In order to allow accurate registration, free-breathing images are required to be free of doubling-artifacts, which arise when tissue motion is greater than scan speed. This work identifies the minimum scanner parameters required to successfully generate free-breathing fast-helical scans without doubling-artifacts. Methods: 10 patients were imaged under free breathing conditions 25 times in alternating directions with a 64-slice CT scanner using a low dose fast helical protocol. A high temporal resolution (0.1s) 4D-CT was generated using a patient specific motion model and patient breathing waveforms, and used as the input for a scanner simulation. Forward projections were calculated using helical cone-beam geometry (800 projections per rotation) and a GPU accelerated reconstruction algorithm was implemented. Various CT scanner detector widths and rotation times were simulated, and verified using a motion phantom. Doubling-artifacts were quantified in patient images using structural similarity maps to determine the similarity between axial slices. Results: Increasing amounts of doubling-artifacts were observed with increasing rotation times > 0.2s for 16×1mm slice scan geometry. No significant increase in doubling artifacts was observed for 64×1mm slice scan geometry up to 1.0s rotation time although blurring artifacts were observed >0.6s. Using a 16×1mm slice scan geometry, a rotation time of less than 0.3s (53mm/s scan speed) would be required to produce images of similar quality to a 64×1mm slice scan geometry. Conclusion: The current generation of 16 slice CT scanners, which are present in most Radiation Oncology departments, are not capable of generating free-breathing sorting-artifact-free images in the majority of patients. The next generation of CT scanners should be capable of at least 53mm/s scan speed in order to use a fast-helical 4D-CT protocol to generate a motion-artifact free 4D-CT. NIH R01CA096679.

60 APPLIED LIFE SCIENCES↗