Search NASA⌕ Search

Engineering topics

Tan, Xiaodong

Publications and source records attributed to Tan, Xiaodong.

Kölliker's Organ Functions as a Developmental Hub in Mouse Cochlea Regulating Spiral Limbus and Tectorial Membrane Development

Kölliker's organ is a transient developmental structure in the mouse cochlea that undergoes significant remodeling postnatally. Utilizing an epithelial-specific conditional deletion mouse model of Prdm16 (marker and regulator of Kölliker's organ), we show that Prdm16 is required for interdental cell development, and thereby the development of the limbal domain of the tectorial membrane and its medial anchorage to the spiral limbus. Additionally, we show that Kölliker's organ is involved in normal tectorial membrane collagen fibril development and maturation. Interestingly, mesenchymal cells of the spiral limbus underneath Prdm16 -deficient Kölliker's organ failed to produce interstitial matrix proteins, resulting in a hypoplastic and truncated spiral limbus, indicating a non-cell autonomous role of Prdm16 in regulating spiral mesenchymal matrix development. Single-cell RNA sequencing identified differentially expressed genes in Prdm16 -deficient Kölliker's organ suggesting a role for connective tissue growth factor (CTGF) downstream Prdm16 in epithelial-mesenchymal signaling involved in spiral limbus matrix deposition. Prdm16 -deficient mice showed a hearing deficit, as indicated by elevated auditory brainstem response thresholds at most frequencies, consistent with the cochlear structural defects. Both sexes were studied. This work establishes Prdm16 as a deafness gene in mice through its role in regulating Kölliker's organ development. Such understanding recognizes Kölliker's organ as a developmental hub regulating multiple surrounding cochlear structures.

Zhang, Hongji↗

Waveguides for neurostimulation in the cochlea

Introduction Optical stimulation has been suggested for neural stimulation to improve cochlear implants. Light allows for more spatially selective activation of neuron populations than electrical current, offering more independent frequency bands along the spiral ganglion. These bands are available to encode acoustic information with anticipated better frequency resolution, improving cochlear implant user performance in noisy listening environments, tonal languages, and music perception. Methods Optical cochlear implants (oCIs) can deliver light either directly via small emitters within the cochlea or via waveguides from external optical sources. We investigated three waveguide designs made from OrmoComp ® , a polymer that cures through ultraviolet (UV) radiation. Waveguides were fabricated via injection molding and coated using dip-coating or thermal reflow, or through aspiration of OrmoComp ® into polyimide tubing that served as the cladding of the waveguide. The choice of fabrication technique directly determined the waveguides' total diameter: thermal reflow yielded ≈940 μm, dip-coating produced ≈306 μm, and aspiration resulted in ≈132 μm core diameter waveguides. Given the human cochlea's small size, we focused on analyzing the 306-μm and 132-μm waveguides, evaluating their optical performance (propagation and bending losses) and mechanical properties (bending stiffness and insertion forces). Furthermore, we evaluated some of these designs in in-vivo guinea pigs experiments. Results For the 100-μm core diameter waveguides, the propagation losses were 12.34 ± 1.26, 1.18 ± 0.88, 1.49 ± 0.58, and 3.43 ± 0.68 dB/cm at 534, 1,375, 1,460, and 1,550 nm, respectively. The respective bending losses at a 2 mm radius of curvature were 5.50 ± 1.32, 0.56 ± 0.26, 0.79 ± 0.18, and 0.64 ± 0.23 dB, and at 1 mm 8.54 ± 1.30, 2.05 ± 0.84, 2.11 ± 0.50, and 1.44 ± 0.37 dB. The bending stiffness of a 1 mm segment of the 100-μm-diameter waveguides was 18.9 ± 2.2 N/m. Insertion forces for the 100-μm-diameter waveguides into an acrylic human-size scala tympani model were < 25 mN. For the waveguides with 306 and 940 μm total diameter, the propagation losses ranged between 0.43 and 2.40 dB/cm at 534, 680, 1,375, and 1,550 nm, between 2.19 and 3.78 dB/cm at 450 and 1,460 nm. Bending losses for 360 degrees at 1,375 nm were 5.0, 2.4, and 0.46 for a bending radius of 2.5-, 3-, and 4-mm. Discussion Our study demonstrated that the polymer OrmoComp ® is suitable for fabricating waveguides to transmit near-infrared radiation. In-vivo experiments showed optically evoked auditory responses originating from optical stimulation in the guinea pigs' first cochlear turn while radiation was delivered. Incoming experiments will focus on evaluating long-term performance of these waveguides in guinea pigs and cats. This study will be designed to provide insights into the waveguides' performance and biocompatibility over extended periods, essential for their potential clinical application in future oCIs.

Kim, Matthew↗

X-Ray Fluorescence Microscopy: A Method of Measuring Ion Concentrations in the Ear

This technical note describes synchrotron x-ray fluorescence microscopy (XFM) as a method for measuring the concentrations of various elements in cross-sections of the ear at extremely high resolution. This method could be of great importance for addressing many open questions in hearing research. XFM uses synchrotron radiation to evoke emissions from many biologically relevant elements in the tissue. The intensity and wavelength of the emitted radiation provide a fingerprint of the tissue composition that can be used to measure the concentration of the elements in the sampled location. Here, we focus on energies that target biologically-relevant elements of the periodic table between magnesium and zinc. Since a highly focused x-ray beam is used, the spot size is well below 1 mu m and the samples can be scanned at a nanometer lateral resolution. This study shows that measurement of the concentrations of different elements is possible in a mid-modiolar cross-section of a mouse cochlea. Images are presented that indicate potassium and chloride "hot spots" in the spiral ligament and the spiral limbus, providing experimental evidence for the potassium recycling pathway and showing the cochlear structures involved. Scans of a section obtained from the incus, one of the middle ear ossicles, in a developing mouse have shown that zinc is not uniformly distributed This supports the hypothesis that zinc plays a special role in the process of ossification. Although limited by sophisticated sample preparation and sectioning, the method provides ample exciting opportunities, to understand the role of genetics and epigenetics on hearing mechanisms in ontogeny and phylogeny.

59 BASIC BIOLOGICAL SCIENCES↗