Search NASA⌕ Search

Engineering topics

Tan, Y.

Publications and source records attributed to Tan, Y..

At least 19 records

Phase coexistence at the first-order Mott transition revealed by pressure-dependent dielectric spectroscopy of κ - (BEDT-TTF) 2 - Cu 2 (CN) 3

The dimer Mott insulator kappa - (BEDT-TTF) 2 - Cu 2 (CN) 3 can be tuned into metallic and superconducting states on applying pressure of 1.5 kbar and more. We have performed dielectric measurements (7.5 kHz to 5 MHz) on kappa - (BEDT-TTF) 2 - Cu 2 (CN) 3 single crystals as a function of temperature (down to T = 8 K) and pressure (up to p = 4.3 kbar). In addition to the relaxor-like dielectric behavior seen below 50 K at p = 0, that moves toward lower temperatures with pressure, a second peak emerges in ε 1 (T) around T = 15 K. When approaching the insulator-metal boundary, this peak diverges rapidly reaching ε 1 ≈ 10 5 . Our dynamical mean-field theory calculations substantiate that the dielectric catastrophe at the Mott transition is not caused by closing the energy gap, but due to the spatial coexistence of correlated metallic and insulating regions. We discuss the percolative nature of the first-order Mott insulator-to-metal transition in all details.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation campaign of HPK prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

In this work, we report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of were irradiated in steps of roughly 2 up to a fluence of 3. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at °C.

47 OTHER INSTRUMENTATION↗

The HITRAN2016 molecular spectroscopic database

This paper describes the contents of the 2016 edition of the HITRAN molecular spectroscopic compilation. The new edition replaces the previous HITRAN edition of 2012 and its updates during the intervening years. The HITRAN molecular absorption compilation is comprised of five major components: the traditional line-by-line spectroscopic parameters required for high-resolution radiative-transfer codes, infrared absorption cross-sections for molecules not yet amenable to representation in a line-by-line form, collision-induced absorption data, aerosol indices of refraction, and general tables such as partition sums that apply globally to the data. The new HITRAN is greatly extended in terms of accuracy, spectral coverage, additional absorption phenomena, added line-shape formalisms, and validity. Moreover, molecules, isotopologues, and perturbing gases have been added that address the issues of atmospheres beyond the Earth. Of considerable note, experimental IR cross-sections for almost 200 additional significant molecules have been added to the database.

Gordon, I. E.↗

A high speed compact microwave interferometer for density fluctuation measurements in Sino-UNIted Spherical Tokamak

A single-channel 3 mm interferometer has been developed for plasma density diagnostics in the Sino-UNIted Spherical Tokamak (SUNIST). The extremely compact microwave interferometer utilizes one corrugated feed horn antenna for both emitting and receiving the microwave. The beam path lies on the equatorial plane so the system would not suffer from beam path deflection problems due to the symmetry of the cross section. A focusing lens group and an oblique vacuum window are carefully designed to boost the signal to noise ratio, which allows this system to show good performance even with the small-diameter central column itself as a reflector, without a concave mirror. The whole system discards the reference leg for maximum compactness, which is particularly suitable for the small-sized tokamak. An auto-correcting algorithm is developed to calculate the phase evolution, and the result displays good phase stability of the whole system. The intermediate frequency is adjustable and can reach its full potential of 2 MHz for best temporal resolution. Multiple measurements during ohmic discharges proved the interferometer’s capability to track typical density fluctuations in SUNIST, which enables this system to be utilized in the study of MHD activities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the beam path deflection for a vertically installed microwave interferometer in SUNIST

Microwave interferometry has been widely employed to provide reliable line averaged electron density measurement on plasma devices. For a vertically installed interferometer on a tokamak, the refraction problem, which distorts the beam path and aggravates power loss at the receiving antenna, may become significant if taking the cross section shape into account. Increasing the frequency of the probing microwave can alleviate the distortion, but at the expense of losing the density resolution. To seek for an optimized frequency, previous calculations are mainly based on the cylindrical column geometry which grossly underestimates the deflection of the beam path induced by the plasma shape, and empirical suggestions indicating n{sub e0}/n{sub c} = 1/2 ∼ 1/3 may not always be the appropriate option. Here a single ray tracing method is applied to estimate the final horizontal deviation at the receiving antenna, which is supposed to represent the level of power loss. The calculation is carried out under the real tokamak geometry in Sino-UNIted Spherical Tokamak (SUNIST) with the cross section parameters obtained from the equilibrium reconstruction, and the result indicates that for a target density of 1.2 × 10{sup 19} m{sup −3}, a frequency of at least 100 GHz is desirable to reduce the power loss to an acceptable level. This would be helpful for the design of a vertically installed interferometer on SUNIST.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transverse profile of the electron beam for the RHIC electron lenses

To compensate for the beam-beam effects from the proton-proton interactions at the two interaction points IP6 and IP8 in the Relativistic Heavy Ion Collider (RHIC), we are constructing two electron lenses (e-lenses) that we plan to install in the interaction region IR10. Before installing them, the electron gun, collector, instrumentation were tested and the electron beam properties were qualified on an electron lens test bench. We will present the test results and discuss our measurement of the electron beam current and of the electron gun perveance. We achieved a maximum current of 1 A with 5 kV energy for both the pulsed- and the DC-beam (which is a long turn-by-turn pulse beam). We measured beam transverse profiles with an Yttrium Aluminum Garnet (YAG) screen and pinhole detector, and compared those to simulated beam profiles. Measurements of the pulsed electron beam stability were obtained by measuring the modulator voltage.

43 PARTICLE ACCELERATORS↗

RHIC electron lenses upgrades

In the Relativistic Heavy Ion Collider (RHIC) 100 GeV polarized proton run in 2015, two electron lenses were used to partially compensate for the head-on beam-beam effect for the first time. Here, we describe the design of the current electron lens, detailing the hardware modifications made after the 2014 commissioning run with heavy ions. A new electron gun with 15-mm diameter cathode is characterized. The electron beam transverse profile was measured using a YAG screen and fitted with a Gaussian distribution. During operation, the overlap of the electron and proton beams was achieved using the electron backscattering detector in conjunction with an automated orbit control program.

43 PARTICLE ACCELERATORS↗

RHIC Abort Kicker Prefire Report

In an attempt to discover any pattern to prefire events, abort prefire kicker data from 2007 to the present day have been recorded. With the 2014 operations concluding, this comprises 8 years of prefire data. Any activities that the Pulsed Power Group did to decrease prefire occurrences were recorded as well, but some information may be missing. The following information is a compilation of the research to date.

43 PARTICLE ACCELERATORS↗

RHIC electron lens beam transport system design considerations

To apply head-on beam-beam compensation for RHIC, two electron lenses are designed and will be installed at IP6 and IP8. Each electron lens has several sub-systems, including electron gun, electron collector, superconducting main solenoid (SM), diagnostics system and power supply system. In addition to these systems, beam transport system which can transport electron beam from electron gun side to collector side is also needed.

43 PARTICLE ACCELERATORS↗