Search NASA⌕ Search

Engineering topics

Tanaka, S

Publications and source records attributed to Tanaka, S.

Ryugu's nucleosynthetic heritage from the outskirts of the Solar System

Little is known about the origin of the spectral diversity of asteroids and what it says about conditions in the protoplanetary disk. Here we show that samples returned from Cb­type asteroid Ryugu have Fe isotopic anomalies indistinguishable from Ivuna­type (CI) chondrites, which are distinct from all other carbonaceous chondrites. Iron isotopes, therefore, demonstrate that Ryugu and CI chondrites formed in a reservoir that was different from the source regions of other carbonaceous asteroids. Growth and migration of the giant planets destabilized nearby planetesimals and ejected some inwards to be implanted into the Main Belt. In this framework, most carbonaceous chondrites may have originated from regions around the birthplaces of Jupiter and Saturn, while the distinct isotopic composition of CI chondrites and Ryugu may reflect their formation further away in the disk, owing their presence in the inner Solar System to excitation by Uranus and Neptune

58 GEOSCIENCES↗

SU-C-207A-03: Development of Proton CT Imaging System Using Thick Scintillator and CCD Camera

Purpose: In the treatment planning of proton therapy, Water Equivalent Length (WEL), which is the parameter for the calculation of dose and the range of proton, is derived by X-ray CT (xCT) image and xCT-WEL conversion. However, about a few percent error in the accuracy of proton range calculation through this conversion has been reported. The purpose of this study is to construct a proton CT (pCT) imaging system for an evaluation of the error. Methods: The pCT imaging system was constructed with a thick scintillator and a cooled CCD camera, which acquires the two-dimensional image of integrated value of the scintillation light toward the beam direction. The pCT image is reconstructed by FBP method using a correction between the light intensity and residual range of proton beam. An experiment for the demonstration of this system was performed with 70-MeV proton beam provided by NIRS cyclotron. The pCT image of several objects reconstructed from the experimental data was evaluated quantitatively. Results: Three-dimensional pCT images of several objects were reconstructed experimentally. A finestructure of approximately 1 mm was clearly observed. The position resolution of pCT image was almost the same as that of xCT image. And the error of proton CT pixel value was up to 4%. The deterioration of image quality was caused mainly by the effect of multiple Coulomb scattering. Conclusion: We designed and constructed the pCT imaging system using a thick scintillator and a CCD camera. And the system was evaluated with the experiment by use of 70-MeV proton beam. Three-dimensional pCT images of several objects were acquired by the system. This work was supported by JST SENTAN Grant Number 13A1101 and JSPS KAKENHI Grant Number 15H04912.

60 APPLIED LIFE SCIENCES↗

SU-F-T-630: Energy Spectral Study On Lipiodol After Trans-Arterial Chemoembolization Using the Flattened and Unflattened Photon Beams

Purpose: SBRT combining transarterial chemoembolization with Lipiodol is expected to improve local control. Our showed that the dose enhancement effect in the Lipiodol with 10X flattening filter free (FFF) was inserted. This study was to investigate the energy fluence variations of electron in the Lipiodol using flattened (FF) and FFF beams. Methods: FF and FFF for 6X and 10X beams by TrueBeam were used in this study. The Lipiodol (3 X 3 X 3 cm{sup 3}) was located at the depth of 5 cm in water, the dose enhancement factor (DEF) and energy fluence were calculated by Monte Carlo (MC) calculations (PHITS). Results: DEFs with FF and FFF of 6X were 17.1% and 24.3% at rebuild-up region in the Lipiodol (5.3cm depth), 7.0% and 17.0% at the center of Lipiodol (6.5cm depth), and −13.2% and −8.2% at behind Lipiodol (8.3cm depth). DEFs with FF and FFF of 10X were 21.7% and 15.3% at rebuild-up region, 8.2% and 10.5% at the center of Lipiodol, and −14.0% and −8.6% at behind Lipiodol. Spectral results showed that the FFF beam contained more low-energy (0–0.3MeV) component of electrons than FF beam, and FF beam contained more high-energy (over 0.3MeV) electrons than FFF beam in Lipiodol. Behind the Lipiodol, build-down effect with FF beam was larger than FFF beam because FF beam contained more high energy electrons. The difference of DEFs between FFF and FF beams for 6X were larger than for 10X. This is because 10X beam contained more high-energy electrons. Conclusion: It was found that the 6XFFF beam gives the largest change of energy fluence and the largest DEF in this study. These phenomena are mainly caused by component of low-energy electrons, and this energy is almost correspond to the boundary of photo electronic dominant and Compton scattering dominant region for photon beams.

60 APPLIED LIFE SCIENCES↗

SU-G-BRB-09: Kompeito-Shot: Development of a Novel Verification System for 3D Beam Alignment Including the Sag of Gantry Head

Purpose: High accuracy of beam axis is required for high-precision radiation therapy. It is impossible to quantitatively and directly evaluate the sagging effect of the gantry head using current methods (star-shot and Winston-Lutz tests) when the gantry head sags under the weight of MLC and X-Y jaws. We introduce a novel method “Kompeito-shot (3D star-shot)” for the verification of 3D beam alignment (3D isocentricity). This method enables direct measurement of the sagging effect. We developed the system and examined the concept of this system. Methods: The system composed of a plastic scintillator (PS), a truncated cone-shaped mirror, a plane mirror and a CCD camera. Two types of PS were compared. One consisted of a column PS (Co system), the other consisted of a column PS inserted into a barrel PS with shading film in between (Co-Ba system). The system was irradiated with a 6-MV photon beam and the scintillation light was measured using the CCD camera through the mirror system. The gantry angle was set from 270 to 300 degrees to mimic the sagging of the gantry head for evaluating the accuracy of the system. The distance between a center of PS and entrance / exit points were calculated to analyze the gantry angle. And, the calculated gantry angle and the irradiated gantry angle were compared. Results: We compared the measured image of Co system and that of Co-Ba system. Entrance and exit areas were visualized clearly. The histogram showing the difference between the calculated gantry angle and the irradiated gantry angle was fitted with a Gaussian function. Mean and standard deviation of Co-Ba system were smaller than that of Co system by one order of magnitude. Conclusion: We developed the Kompeito-shot system and evaluated the accuracy of the system. The basic concept works for the verification of 3D isocentricity.

60 APPLIED LIFE SCIENCES↗

Evidence for the Suppressed Decay B{sup -}{yields}DK{sup -}, D{yields}K{sup +}{pi}{sup -}

The suppressed decay chain B{sup -}{yields}DK{sup -}, D{yields}K{sup +}{pi}{sup -}, where D indicates a D{sup 0} or D{sup 0} state, provides important information on the CP-violating angle {phi}{sub 3}. We measure the ratio R{sub DK} of the decay rates to the favored mode B{sup -}{yields}DK{sup -}, D{yields}K{sup -}{pi}{sup +} to be R{sub DK}=[1.63{sub -0.41}{sup +0.44}(stat){sub -0.13}{sup +0.07}(syst)]x10{sup -2}, which indicates the first evidence of the signal with a significance of 4.1{sigma}. We also measure the asymmetry A{sub DK} between the charge-conjugate decays to be A{sub DK}=-0.39{sub -0.28}{sup +0.26}(stat){sub -0.03}{sup +0.04}(syst). The results are based on the full 772x10{sup 6} BB pair data sample collected at the {Upsilon}(4S) resonance with the Belle detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of optical emission spectroscopy for He I considering the spatial structure of radiation trapping in MAP-II divertor simulator

The He I optical emission spectroscopy that considers the spatial structure of radiation trapping was proposed by us and was applied to a MAP-II divertor simulator. The spatial distribution of the optical escape factor was calculated from the n {sup 1}P (n{>=}3) state profiles measured by visible spectroscopy. The profile of 2 {sup 1}P, which is immeasurable by visible spectroscopy, needs to be broader than that of the 3 {sup 1}P state. The sensitivity of the 2 {sup 1}P profile to the T{sub e} value estimated by He I spectroscopy is investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preparation and CO{sub 2} adsorption properties of aminopropyl-functionalized mesoporous silica microspheres

Aminopropyl-functionalized mesoporous silica microspheres (AF-MSM) were synthesized by a simple one-step modified Stober method. Dodecylamine (DDA) was used as the catalyst for the hydrolysis and condensation of the silica source and as the molecular template to prepare the ordered mesopores. The mesoporous silica surfaces were modified to aminopropyl groups by the co-condensation of tetraethoxysilane (TEOS) with 3-aminopropyltriethoxysilane (APTES), up to a maximum of 20 mol.% APTES content in the silica source. The particle size, Brunauer-Emmet-Teller (BET) specific surface area, and mesoporous regularity decreased with increasing APTES content. It is believed that this result is caused by a decreasing amount of DDA incorporated into AF-MSM with increasing APTES content. It was also confirmed that the spherical shape and the mesostructure were maintained even if 20 mol.% of APTES was added to the silica source. Moreover, AF-MSM was applied to the CO{sub 2} adsorbent. The breakthrough time of the CO{sub 2} and CO{sub 2} adsorption capacities increased with increasing APTES content. The adsorption capacity of CO{sub 2} for AF-MSM, prepared at 20 mol.% APTES, was 0.54 mmol g{sup -1}. Carbon dioxide adsorbed onto AF-MSM was completely desorbed by heating in a N{sub 2} purge at 423 K for 30 min.

01 COAL, LIGNITE, AND PEAT↗

Development of wide-band X-ray/gamma-ray imagers using reach through APD arrays

It is quite important to obtain wide band spectra of gamma-ray bursts (GRBs) at the same time in order to probe the emission processes or the structure of GRBs. An avalanche photo diode (APD) is a compact photon sensor with an internal gain of 100. We have developed an X-ray/gamma-ray detector using a back-illuminated reach-through APD (5x5 mm{sup 2}) optically coupled with a conventional CsI(Tl) scintillator, which covers typically from 1 keV to 1 MeV. Further, we developed a 1-dimensional array of the 8/16 APDs (net 16x20 mm{sup 2}) for the purpose of an imaging photon detector to be used in future GRB missions. Here we present the current status and performance of our hybrid detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Insights from multiple structures of the shell proteins from the [beta]-carboxysome

Carboxysomes are primitive bacterial organelles that function as a part of a carbon concentrating mechanism (CCM) under conditions where inorganic carbon is limiting. The carboxysome enhances the efficiency of cellular carbon fixation by encapsulating together carbonic anhydrase and the CO{sub 2}-fixing enzyme ribulose-1,5-bisphosphate carboxylase/oxygenase (RuBisCO). The carboxysome has a roughly icosahedral shape with an outer shell between 800 and 1500 {angstrom} in diameter, which is constructed from a few thousand small protein subunits. In the cyanobacterium Synechocystis sp. PCC 6803, the previous structure determination of two homologous shell protein subunits, CcmK2 and CcmK4, elucidated how the outer shell is formed by the tight packing of CcmK hexamers into a molecular layer. Here we describe the crystal structure of the hexameric shell protein CcmK1, along with structures of mutants of both CcmK1 and CcmK2 lacking their sometimes flexible C-terminal tails. Variations in the way hexamers pack into layers are noted, while sulfate ions bound in pores through the layer provide further support for the hypothesis that the pores serve for transport of substrates and products into and out of the carboxysome. One of the new structures provides a high-resolution (1.3 {angstrom}) framework for subsequent computational studies of molecular transport through the pores. Crystal and solution studies of the C-terminal deletion mutants demonstrate the tendency of the terminal segments to participate in protein-protein interactions, thereby providing a clue as to which side of the molecular layer of hexameric shell proteins is likely to face toward the carboxysome interior.

36 MATERIALS SCIENCE↗

Atomic-level models of the bacterial carboxysome shell

The carboxysome is a bacterial microcompartment that functions as a simple organelle by sequestering enzymes involved in carbon fixation. The carboxysome shell is roughly 800 to 1400 angstroms in diameter and is assembled from several thousand protein subunits. Previous studies have revealed the three-dimensional structures of hexameric carboxysome shell proteins, which self-assemble into molecular layers that most likely constitute the facets of the polyhedral shell. Here, we report the three-dimensional structures of two proteins of previously unknown function, CcmL and OrfA (or CsoS4A), from the two known classes of carboxysomes, at resolutions of 2.4 and 2.15 angstroms. Both proteins assemble to form pentameric structures whose size and shape are compatible with formation of vertices in an icosahedral shell. Combining these pentamers with the hexamers previously elucidated gives two plausible, preliminary atomic models for the carboxysome shell.

59 BASIC BIOLOGICAL SCIENCES↗

R_transport_matrices of the Fast Extraction Beam (FEB) of the AGS, and Beam Parameters at the Starting point of the AtR Line

As part of the task to improve and further automate the 'AtR BPM Application' we provide the theoretically calculated R-transport-matrices for the following beam line sections, which are shown schematically in Figure 1: (a) the Fast Extraction Beam section (FEB) of the AGS synchrotron. The FEB section starts at the middle of the GlO-kicker and ends at the middle of the H1 0{_}septum. (b) the Drift Extraction Channel (DEC) section of the AGS synchrotron. The DEC section starts at the middle of the H10{_}septum, continues along the fringe field region of the H11,H12, and H13 AGS main magnets, and ends at the starting point of the AtR line. The knowledge of these R-transport-matrices are needed in order to calculate the beam parameters at the beginning of the AtR line, which in turn, are required to calculate the magnet settings of the U{_}line, that match the U{_}line into the W{_}line. Also by incorporating these R{_}matrices into the model of the AtR line, the G10 kicker and the H10 septum are included in the AtR model therefore one can investigate any 'jitter' of either the GlO{_}kicker or HlO{_}septum by looking at the trajectory of the beam in the AtR line.

43 PARTICLE ACCELERATORS↗

Analysis of particle penetration into aluminum plate using underwater shock wave

Some techniques using underwater shock waves have been developed for several material processing applications: explosive welding, shock compaction, and shock synthesis. In this research, a new technique was developed for surface modification of an aluminum plate. Diamond particles were accelerated by an underwater shock wave and penetrated into an aluminum plate, creating a surface coating of diamond on the aluminum plate. In the observation of the cross-section of the recovered Al-diamond composite, a rich diamond layer was confirmed at about 200 {mu}m depth. XRD and wear measurements were conducted for the recovered Al-diamond composite. We also report on the optical observation of the underwater shock wave in this paper.

36 MATERIALS SCIENCE↗

The GEANT4 Visualisation System

The Geant4 Visualization System is a multi-driver graphics system designed to serve the Geant4 Simulation Toolkit. It is aimed at the visualization of Geant4 data, primarily detector descriptions and simulated particle trajectories and hits. It can handle a variety of graphical technologies simultaneously and interchangeably, allowing the user to choose the visual representation most appropriate to requirements. It conforms to the low-level Geant4 abstract graphical user interfaces and introduces new abstract classes from which the various drivers are derived and that can be straightforwardly extended, for example, by the addition of a new driver. It makes use of an extendable class library of models and filters for data representation and selection. The Geant4 Visualization System supports a rich set of interactive commands based on the Geant4 command system. It is included in the Geant4 code distribution and maintained and documented like other components of Geant4.

97 MATHEMATICS AND COMPUTING↗